Novel CeO2-based screen-printed potentiometric electrodes for pH monitoring

被引:25
|
作者
Betelu, S. [1 ]
Polychronopoulou, K. [2 ]
Rebholz, C. [2 ]
Ignatiadis, I. [1 ]
机构
[1] Bur Rech Geol & Minieres, Environm & Proc Div, F-45060 Orleans 2, France
[2] Univ Cyprus, Mech & Mfg Engn Dept, CY-1678 Nicosia, Cyprus
关键词
pH sensing; Cerium-based oxides; Mass modified screen-printed electrodes; Monitoring; PROTON CONDUCTING CERAMICS; SUPPORTED-RH CATALYSTS; METAL-OXIDE ELECTRODES; RUTHENIUM DIOXIDE; ALKALINE-PHOSPHATASE; CERIA CERAMICS; SENSORS; FILM; MEMBRANE; TEMPERATURES;
D O I
10.1016/j.talanta.2011.09.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nuclear waste repositories are being installed in deep excavated rock formations in some places in Europe to isolate and store radioactive waste. In France, the Callovo-Oxfordian formation (COx) is a possible candidate for nuclear waste storage. This work investigates the applicability of CeO2-based oxides (CeO2, Ce0.8Sm0.2O2 and Ce0.8Zr0.2O2) for monitoring the pH of the COx pore water (T = 25 degrees C). The study is limited to the pH range between 5.5 and 13.2, which includes the pH values that have been encountered or are anticipated in the COx formation during its evolution as radioactive waste repository due mainly to alkalinisation, an increase in salinity, and a decrease in redox potential. Screen-printing was done to assemble electrodes and rapidly generate data sets. The electrochemical behavior of CeO2-based screen-printed electrodes (CeO2-based SPEs) was determined by cyclic voltammetry and electrochemical impedance spectroscopy. The use of the electrodes for pH sensing was then evaluated by potentiometric measurements. The feasibility of measuring pH with CeO2-based SPEs was first tested in NH4Cl/NH3 buffer solutions, leading to electrode calibration over the widest range of pH, from around neutral to basic pH. Experiments were then conducted in NaHCO3/Na2CO3 buffer samples similar to conditions prevailing in the COx formation. Ce0.8Zr0.2O2 SPEs exhibit a near-Nernstian behavior (sensitivity -(51 +/- 2) mV/pH) in the pH range of 5.5-13.2 at 25 degrees C. Electrode response was slightly affected by the direction of the pH change. Electrode reliability was clearly demonstrated for pH monitoring. Probes based on the same components, but more durably designed, could be considered for pH measurements in radioactive waste repositories. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 50 条
  • [31] Cost Effective Soil pH Sensor Using Carbon-Based Screen-Printed Electrodes
    Singh, Mukul
    Patkar, Rajul S.
    Vinchurkar, Madhuri
    Baghini, Maryam Shojaei
    IEEE SENSORS JOURNAL, 2020, 20 (01) : 47 - 54
  • [32] MIP-Based Screen-Printed Potentiometric Cell for Atrazine Sensing
    Alberti, Giancarla
    Zanoni, Camilla
    Spina, Stefano
    Magnaghi, Lisa Rita
    Biesuz, Raffaela
    CHEMOSENSORS, 2022, 10 (08)
  • [33] Electrochromic biosensors based on screen-printed Prussian Blue electrodes
    Aller-Pellitero, Miguel
    Fremeau, Josephine
    Villa, Rosa
    Guirado, Gonzalo
    Lakard, Boris
    Hihn, Jean-Yves
    Javier del Campo, F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 : 591 - 597
  • [34] Deinking of Screen-Printed Electrodes Printed on Invasive Plant-Based Paper
    Kavcic, Urska
    Karlovits, Igor
    Zule, Janja
    SUSTAINABILITY, 2020, 12 (04)
  • [35] Electrochemical characterization of screen-printed carbonaceous electrodes for the determination of peroxidase activity in novel screen-printed flow-through modules
    Matthias Stiene
    Ursula Bilitewski
    Analytical and Bioanalytical Chemistry, 2002, 372 : 240 - 247
  • [36] Electrochemical characterization of screen-printed carbonaceous electrodes for the determination of peroxidase activity in novel screen-printed flow-through modules
    Stiene, M
    Bilitewski, U
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (02) : 240 - 247
  • [37] Design and development of an amperometric immunosensor based on screen-printed electrodes
    Mistry, Kalyan Kumar
    Layek, Keya
    Chell, Tarak Nath
    Chaudhuri, Chirasree Roy
    Saha, Hiranmay
    ANALYTICAL METHODS, 2016, 8 (15) : 3096 - 3101
  • [38] Screen-Printed Potentiometric Sensors for Chloride Measurement in Soils
    Cranny, A.
    Harris, N. R.
    White, N. M.
    Barrett-Lennard, E.
    Coles, N.
    Rivers, M.
    Smettem, K.
    Wu, J.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1157 - 1160
  • [39] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    El-Attar, Rehab O.
    Hendawy, Hassan A. M.
    Khaled, Elmorsy
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (11) : 3019 - 3029
  • [40] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    Rehab O. El-Attar
    Hassan A. M. Hendawy
    Elmorsy Khaled
    Journal of the Iranian Chemical Society, 2020, 17 : 3019 - 3029