Novel CeO2-based screen-printed potentiometric electrodes for pH monitoring

被引:25
|
作者
Betelu, S. [1 ]
Polychronopoulou, K. [2 ]
Rebholz, C. [2 ]
Ignatiadis, I. [1 ]
机构
[1] Bur Rech Geol & Minieres, Environm & Proc Div, F-45060 Orleans 2, France
[2] Univ Cyprus, Mech & Mfg Engn Dept, CY-1678 Nicosia, Cyprus
关键词
pH sensing; Cerium-based oxides; Mass modified screen-printed electrodes; Monitoring; PROTON CONDUCTING CERAMICS; SUPPORTED-RH CATALYSTS; METAL-OXIDE ELECTRODES; RUTHENIUM DIOXIDE; ALKALINE-PHOSPHATASE; CERIA CERAMICS; SENSORS; FILM; MEMBRANE; TEMPERATURES;
D O I
10.1016/j.talanta.2011.09.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nuclear waste repositories are being installed in deep excavated rock formations in some places in Europe to isolate and store radioactive waste. In France, the Callovo-Oxfordian formation (COx) is a possible candidate for nuclear waste storage. This work investigates the applicability of CeO2-based oxides (CeO2, Ce0.8Sm0.2O2 and Ce0.8Zr0.2O2) for monitoring the pH of the COx pore water (T = 25 degrees C). The study is limited to the pH range between 5.5 and 13.2, which includes the pH values that have been encountered or are anticipated in the COx formation during its evolution as radioactive waste repository due mainly to alkalinisation, an increase in salinity, and a decrease in redox potential. Screen-printing was done to assemble electrodes and rapidly generate data sets. The electrochemical behavior of CeO2-based screen-printed electrodes (CeO2-based SPEs) was determined by cyclic voltammetry and electrochemical impedance spectroscopy. The use of the electrodes for pH sensing was then evaluated by potentiometric measurements. The feasibility of measuring pH with CeO2-based SPEs was first tested in NH4Cl/NH3 buffer solutions, leading to electrode calibration over the widest range of pH, from around neutral to basic pH. Experiments were then conducted in NaHCO3/Na2CO3 buffer samples similar to conditions prevailing in the COx formation. Ce0.8Zr0.2O2 SPEs exhibit a near-Nernstian behavior (sensitivity -(51 +/- 2) mV/pH) in the pH range of 5.5-13.2 at 25 degrees C. Electrode response was slightly affected by the direction of the pH change. Electrode reliability was clearly demonstrated for pH monitoring. Probes based on the same components, but more durably designed, could be considered for pH measurements in radioactive waste repositories. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 50 条
  • [21] PALLADIUM-DOPED SCREEN-PRINTED ELECTRODES FOR MONITORING FORMALDEHYDE
    WANG, J
    PEDRERO, M
    CAI, XH
    ANALYST, 1995, 120 (07) : 1969 - 1972
  • [22] Graphite Screen-Printed Electrodes Applied for the Accurate and Reagentless Sensing of pH
    Galdino, Flavia E.
    Smith, Jamie P.
    Kwamou, Sophie I.
    Kampouris, Dimitrios K.
    Iniesta, Jesus
    Smith, Graham C.
    Bonacin, Juliano A.
    Banks, Craig E.
    ANALYTICAL CHEMISTRY, 2015, 87 (23) : 11666 - 11672
  • [23] Novel Green Screen-Printed Potentiometric Sensor for Monitoring Antihistamine Drug Chlorphenoxamine HCl in Various Matrices
    Ashraf, Ahmed
    El-Zeany, Badr A.
    Sedik, Ghada A.
    Rostom, Yasmin
    ElDin, Norhan Badr
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (07)
  • [24] A Novel Screen-Printed and Carbon Paste Electrodes for Potentiometric Determination of Uranyl(II) Ion in Spiked Water Samples
    Tamer Awad Ali
    Gehad G. Mohamed
    Refat F. Aglan
    Mai A. Mourad
    Russian Journal of Electrochemistry, 2018, 54 : 201 - 215
  • [25] A Novel Screen-Printed and Carbon Paste Electrodes for Potentiometric Determination of Uranyl(II) Ion in Spiked Water Samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    Aglan, Refat F.
    Mourad, Mai A.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (02) : 201 - 215
  • [26] Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring
    Raúl A. Sánchez-Moreno
    M. Jesús Gismera
    M. Teresa Sevilla
    Jesús R. Procopio
    Analytical and Bioanalytical Chemistry, 2010, 397 : 331 - 338
  • [27] Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring
    Sanchez-Moreno, Raul A.
    Jesus Gismera, M.
    Teresa Sevilla, M.
    Procopio, Jesus R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (01) : 331 - 338
  • [28] Fabrication of screen-printed electrodes with long-term stability for voltammetric and potentiometric applications
    Hong, Seongjun
    Oh, Sebin
    Kim, Eunhyeong
    Park, Eunchul
    Chun, Hyen Chung
    Kim, In Tae
    Kim, Yang-Rae
    SENSORS AND ACTUATORS REPORTS, 2024, 8
  • [29] Screen-printed electrodes for environmental monitoring of heavy metal ions: a review
    John Barton
    María Begoña González García
    David Hernández Santos
    Pablo Fanjul-Bolado
    Alberto Ribotti
    Margaret McCaul
    Dermot Diamond
    Paolo Magni
    Microchimica Acta, 2016, 183 : 503 - 517
  • [30] Screen-printed electrodes for environmental monitoring of heavy metal ions: a review
    Barton, John
    Gonzalez Garcia, Maria Begona
    Hernandez Santos, David
    Fanjul-Bolado, Pablo
    Ribotti, Alberto
    McCaul, Margaret
    Diamond, Dermot
    Magni, Paolo
    MICROCHIMICA ACTA, 2016, 183 (02) : 503 - 517