Measurement of the midpalatal suture width A comparison of flat-panel volume computed tomography to histomorphometric analysis in a porcine model

被引:27
|
作者
Fricke-Zech, Susanne [1 ]
Gruber, Rudolf M.
Dullin, Christian
Zapf, Antonia
Kramer, Franz-Josef [2 ]
Kubein-Meesenburg, Dietmar [1 ]
Hahn, Wolfram [1 ]
机构
[1] Univ Goettingen, Dept Orthodont, D-37099 Gottingen, Germany
[2] Univ Goettingen, Dept Oral & Maxillofacial Surg, D-37099 Gottingen, Germany
关键词
Midpalatal suture; fpVCT; Histomorphometric analysis; Porcine; RAPID MAXILLARY EXPANSION; PALATAL EXPANSION; PERFORMANCE EVALUATION; CT; SKELETAL; ADULTS; BONE; FPVCT; AGE; MORPHOLOGY;
D O I
10.2319/040311-238.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To conduct a pilot study to investigate the potentiality to determine the midpalatal sutural width radiographically with a flat-panel volume computed tomography (fpVCT) in a porcine model. Materials and Methods: Bone samples from the midpalatal suture of five young (16 weeks) and five old (200 weeks) sus scrofa domestica were gathered. The midpalatal suture width was measured via fpVCT and compared to respective histological preparations. Results with P < .05 were considered significant. Results: The data obtained by fpVCT and by histomorphometric analysis reveal a highly significant age dependency of the measured suture width (both P < .0001), with lower suture width values in older subjects compared to the younger group. The averaged suture widths measured in the fpVCT images shows a distinctively higher mean compared to the histomorphometric data with high statistical significance (P < .0001). The evaluated difference between both methods was almost constant. Conclusion: fpVCT is a powerful tool for determining midpalatal sutural width. (Angle Orthod. 2012;82:145-150.)
引用
收藏
页码:145 / 150
页数:6
相关论文
共 38 条
  • [31] Pooled blood volume measured by final flat-panel detector computed tomography predicts outcome after endovascular thrombectomy for acute ischemic stroke
    Kawano, Dai
    Fukuda, Kenji
    Takeshita, Sho
    Fukumoto, Hironori
    Horio, Yoshinobu
    Ogata, Toshiyasu
    Higashi, Toshio
    Inoue, Tooru
    Abe, Hiroshi
    WORLD NEUROSURGERY-X, 2023, 19
  • [32] Detection of different tumor growth kinetics in single transgenic mice with oncogene-induced mammary carcinomas by flat-panel volume computed tomography
    Jannasch, Katharina
    Dullin, Christian
    Heinlein, Christina
    Krepulat, Frauke
    Wegwitz, Florian
    Deppert, Wolfgang
    Alves, Frauke
    INTERNATIONAL JOURNAL OF CANCER, 2009, 125 (01) : 62 - 70
  • [33] Flat-panel detector-based volume computed tomography: A novel 3D Imaging technique to monitor osteolytic bone lesions in a mouse tumor metastasis model
    Missbach-Guentner, Jeannine
    Dullin, Christian
    Zientkowska, Marta
    Domeyer-Missbach, Melanie
    Kimmina, Sarah
    Obenauer, Silvia
    Kauer, Fritz
    Stuehmer, Walter
    Grabbe, Eckhardt
    Vogel, Wolfgang F.
    Alves, Frauke
    NEOPLASIA, 2007, 9 (09): : 755 - 765
  • [34] Analysis of tumor vessel supply in lewis lung carcinoma in mice by fluorescent microsphere distribution and imaging with micro- and flat-panel computed tomography
    Savai, R
    Wolf, JC
    Greschus, S
    Eul, BG
    Schermuly, RT
    Hänze, J
    Voswinckel, R
    Langheinrich, AC
    Grimminger, F
    Traupe, H
    Seeger, W
    Rose, F
    AMERICAN JOURNAL OF PATHOLOGY, 2005, 167 (04): : 937 - 946
  • [35] Metallic Artifacts From Internal Scaphoid Fracture Fixation Screws Comparison Between C-Arm Flat-Panel, Cone-Beam, and Multidetector Computed Tomography
    Finkenstaedt, Tim
    Morsbach, Fabian
    Calcagni, Maurizio
    Vich, Magdalena
    Pfirrmann, Christian W. A.
    Alkadhi, Hatem
    Runge, Val M.
    Andreisek, Gustav
    Guggenberger, Roman
    INVESTIGATIVE RADIOLOGY, 2014, 49 (08) : 532 - 539
  • [36] Imaging artifact and exposure conditions in limited-volume cone-beam computed tomography: Comparison between an image intensifier system and a flat panel detector
    Naitoh M.
    Hirukawa A.
    Katsumata A.
    Saburi K.
    Okumura S.
    Ariji E.
    Oral Radiology, 2006, 22 (2) : 69 - 74
  • [37] Ability of chest X-ray to detect faint shadows documented as ground-glass attenuation in images of computed tomography: A comparison between flat-panel detector radiography and film-screen radiography
    Nagatani, Yukihiro
    Nitta, Norihisa
    Ikeda, Mitsuru
    Kitahara, Hitoshi
    Otani, Hideji
    Seko, Ayumi
    Tanaka, Toyohiko
    Murakami, Yoko
    Takahashi, Masashi
    Murata, Kiyoshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (03) : 384 - 390
  • [38] Semiautomatic Landmark-Based Two-Dimensional-Three-Dimensional Image Fusion in Living Mice: Correlation of Near-Infrared Fluorescence Imaging of Cy5.5-Labeled Antibodies with Flat-Panel Volume Computed Tomography
    Dullin, Christian
    Zientkowska, Marta
    Napp, Joanna
    Missbach-Guentner, Jeannine
    Krell, Hans-Willi
    Mueller, Friedernann
    Grabbe, Eckhardt
    Tietze, Lutz-F.
    Alves, Frauke
    MOLECULAR IMAGING, 2009, 8 (01): : 2 - 14