Measurement of the midpalatal suture width A comparison of flat-panel volume computed tomography to histomorphometric analysis in a porcine model

被引:27
|
作者
Fricke-Zech, Susanne [1 ]
Gruber, Rudolf M.
Dullin, Christian
Zapf, Antonia
Kramer, Franz-Josef [2 ]
Kubein-Meesenburg, Dietmar [1 ]
Hahn, Wolfram [1 ]
机构
[1] Univ Goettingen, Dept Orthodont, D-37099 Gottingen, Germany
[2] Univ Goettingen, Dept Oral & Maxillofacial Surg, D-37099 Gottingen, Germany
关键词
Midpalatal suture; fpVCT; Histomorphometric analysis; Porcine; RAPID MAXILLARY EXPANSION; PALATAL EXPANSION; PERFORMANCE EVALUATION; CT; SKELETAL; ADULTS; BONE; FPVCT; AGE; MORPHOLOGY;
D O I
10.2319/040311-238.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To conduct a pilot study to investigate the potentiality to determine the midpalatal sutural width radiographically with a flat-panel volume computed tomography (fpVCT) in a porcine model. Materials and Methods: Bone samples from the midpalatal suture of five young (16 weeks) and five old (200 weeks) sus scrofa domestica were gathered. The midpalatal suture width was measured via fpVCT and compared to respective histological preparations. Results with P < .05 were considered significant. Results: The data obtained by fpVCT and by histomorphometric analysis reveal a highly significant age dependency of the measured suture width (both P < .0001), with lower suture width values in older subjects compared to the younger group. The averaged suture widths measured in the fpVCT images shows a distinctively higher mean compared to the histomorphometric data with high statistical significance (P < .0001). The evaluated difference between both methods was almost constant. Conclusion: fpVCT is a powerful tool for determining midpalatal sutural width. (Angle Orthod. 2012;82:145-150.)
引用
收藏
页码:145 / 150
页数:6
相关论文
共 38 条
  • [21] Semi-automatic classification of skeletal morphology in genetically altered mice using flat-panel volume computed tomography
    Dullin, Christian
    Missbach-Guentner, Jeannine
    Vogel, Wolfgang F.
    Grabbe, Eckhardt
    Alves, Frauke
    PLOS GENETICS, 2007, 3 (07) : 1232 - 1243
  • [22] In Vitro High-Resolution Flat-Panel Computed Tomographic Arthrography for Artificial Cartilage Defect Detection Comparison With Multidetector Computed Tomography
    Guggenberger, Roman
    Winklhofer, Sebastian
    Spiczak, Jochen V.
    Andreisek, Gustav
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 614 - 621
  • [23] Implementation of secondary reconstructions of flat-panel volume computed tomography (fpVCT) and otological planning software for anatomically based cochlear implantation
    Mueller-Graff, Franz-Tassilo
    Ilgen, Lukas
    Schendzielorz, Philipp
    Voelker, Johannes
    Taeger, Johannes
    Kurz, Anja
    Hagen, Rudolf
    Neun, Tilmann
    Rak, Kristen
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 279 (5) : 2309 - 2319
  • [24] Implementation of secondary reconstructions of flat-panel volume computed tomography (fpVCT) and otological planning software for anatomically based cochlear implantation
    Franz-Tassilo Müller-Graff
    Lukas Ilgen
    Philipp Schendzielorz
    Johannes Voelker
    Johannes Taeger
    Anja Kurz
    Rudolf Hagen
    Tilmann Neun
    Kristen Rak
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 2309 - 2319
  • [25] Application of Flat-Panel Volume Computed Tomography to Evaluate Cerebral Hemorrhage After Mechanical Thrombectomy of Acute Embolic Stroke of the Anterior Circulation
    Yen, Ho-Hsian
    Chien, Chun
    Lee, I-Hui
    Chen, Shih-Pin
    Luo, Chao-Bao
    Lin, Chung-Jung
    Chen, Shu-Ting
    Yuan, Wei-Hsin
    Kuo, Yu
    Wu, Chia-Hung
    Chang, Feng-Chi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (06) : 919 - 925
  • [26] Concept of a selective tumour therapy and its evaluation by near-infrared fluorescence imaging and flat-panel volume computed tomography in mice
    Alves, Frauke
    Dullin, Christian
    Napp, Joanna
    Missbach-Guentner, Jeannine
    Jannasch, Katharina
    Mathejczyk, Julia
    Pardo, Luis A.
    Stuehmer, Walter
    Tietze, Lutz-F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (02) : 286 - 293
  • [27] STUDY OF CONFORMABILITY OF THE NEW LEO PLUS STENT TO A CURVED VASCULAR MODEL USING FLAT-PANEL DETECTOR COMPUTED TOMOGRAPHY (DYNACT)
    Valdivia y Alvarado, Miguel
    Ebrahimi, Nilou
    Benndorf, Goetz
    NEUROSURGERY, 2009, 64 (03) : S130 - S134
  • [28] Dynamic imaging of a model of intracranial saccular aneurysms using ultra-high-resolution flat-panel volumetric computed tomography
    Mitha, Alim P.
    Reichardt, Benjamin
    Grasruck, Michael
    Macklin, Eric
    Bartling, Soenke
    Leidecker, Christianne
    Schmidt, Bernhard
    Flohr, Thomas
    Brady, Thomas J.
    Ogilvy, Christopher S.
    Gupta, Rajiv
    JOURNAL OF NEUROSURGERY, 2009, 111 (05) : 947 - 957
  • [29] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Catherine M. Phan
    Eric A. Macklin
    Miriam A. Bredella
    Monica Dadrich
    Paul Flechsig
    Albert J. Yoo
    Joshua A. Hirsch
    Rajiv Gupta
    Skeletal Radiology, 2011, 40 : 1065 - 1072
  • [30] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Phan, Catherine M.
    Macklin, Eric A.
    Bredella, Miriam A.
    Dadrich, Monica
    Flechsig, Paul
    Yoo, Albert J.
    Hirsch, Joshua A.
    Gupta, Rajiv
    SKELETAL RADIOLOGY, 2011, 40 (08) : 1065 - 1072