Outcomes of transvenous lead extraction in patients with lead perforation: A single-center experience

被引:12
|
作者
Zhou, Xu [1 ]
Ze, Feng [1 ]
Li, Ding [1 ]
Wang, Long [1 ]
Guo, Jihong [1 ]
Li, Xuebin [1 ]
机构
[1] Peking Univ, Peoples Hosp, Dept Cardiac Electrophysiol, 11 Xizhimen South St, Beijing 100044, Peoples R China
关键词
lead perforation; percutaneous subxiphoid pericardial puncture; pericardial effusion; RIGHT-VENTRICULAR PERFORATION; HEART PERFORATION; ICD LEAD; PACEMAKER; MANAGEMENT; SUBACUTE;
D O I
10.1002/clc.23327
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Management of cardiac perforation caused by the lead of a cardiac implantable electronic device (CIED) is currently unclear. This study evaluated the outcomes of transvenous lead extraction (TLE) in patients with cardiac perforation caused by a transvenous lead. Hypothesis Removal of perforated lead by transvenous approach is safe and effective. Methods The medical records of all patients diagnosed with cardiac perforation by a pacing or defibrillator lead in Peking University People's Hospital from January 2008 to January 2019 were reviewed. We included patients who were managed by TLE. Results A total of 53 patients (30 men; mean age: 67 +/- 15 years) with lead perforation managed by TLE were included. Most of the perforated leads (94.9%) were pacemaker leads. Forty-three leads (81.1%) were implanted within 1 year. Ten patients with a high risk of hemopericardium underwent percutaneous subxiphoid pericardial puncture prior to TLE. All 53 culprit leads were removed completely without major complications. Simple traction with or without a locking stylet was sufficient in 51 patients (96.2%). Forty-eight patients (90.6%) had a new active-fixation lead reimplanted. No patients showed evidence of new-onset or worsening pericardial effusion during the procedure and hospital stay. During a median follow-up time of 16 months, no recurrence of symptoms associated with lead perforation or CIED-related infection were reported. Conclusion In most patients with lead perforation, TLE can be a safe and effective management approach.
引用
收藏
页码:386 / 393
页数:8
相关论文
共 50 条
  • [41] Feasibility and safety of left ventricular lead reimplantation after transvenous lead extraction: a single centre experience
    Solarino, G.
    Zucchelli, G.
    Soldati, E.
    Di Cori, A.
    Paperini, L.
    Segreti, L.
    Viani, S.
    Bandera, F.
    De Lucia, R.
    Bongiorni, M. G.
    EUROPEAN HEART JOURNAL, 2010, 31 : 406 - 406
  • [42] Timing of delayed perforation with the St. Jude Riata lead: A single-center experience and a review of the literature
    Danik, Stephan B.
    Mansour, Moussa
    Heist, E. Kevin
    Ellinor, Patrick
    Milan, David
    Singh, Jagmeet
    Das, Saumya
    Reddy, Vivek
    D'Avila, Andre
    Ruskin, Jeremy N.
    Mela, Theofanie
    HEART RHYTHM, 2008, 5 (12) : 1667 - 1672
  • [43] Transvenous lead extraction
    Tofield, A.
    EUROPEAN HEART JOURNAL, 2017, 38 (32) : 2457 - 2458
  • [44] Transvenous Lead Extraction Outcomes in Hemodialysis Patients: Assessing the Risk of Infection
    Paul, Aritra
    Hayashi, Katsuhide
    Baranowski, Bryan
    Kochar, Arshneel
    Martin, David
    Taigen, Tyler
    Rickard, John
    Hussein, Ayman
    Wazni, Oussama
    Callahan, Thomas
    CIRCULATION, 2024, 150
  • [45] Transvenous lead extraction of pacing and defibrillator leads: a single-centre experience
    Geselle, P-J.
    Poesen, R.
    Rega, F.
    Koopman, P.
    Nuyens, D.
    Heidbuechel, H.
    Willems, R.
    ACTA CARDIOLOGICA, 2011, 66 (05) : 678 - 678
  • [46] Deep sedation for transvenous lead extraction: a large single-centre experience
    Bode, Kerstin
    Whittaker, Peter
    Lucas, Johannes
    Muessigbrodt, Andreas
    Hindricks, Gerhard
    Richter, Sergio
    Doering, Michael
    EUROPACE, 2019, 21 (08): : 1246 - 1253
  • [47] Single center experience with the novel rotating dilator sheath TightRail™ Sub-C in transvenous lead extraction
    Frei, Celine
    Hofer, Daniel
    Jan, Steffel
    Grebmer, Christian
    Breitenstein, Alexander
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (08) : 1738 - 1743
  • [48] Timing of esophageal stent placement and outcomes in patients with esophageal perforation: a single-center experience
    Navaneethan, Udayakumar
    Lourdusamy, Vennisvasanth
    Duvuru, Sudhir
    Lourdusamy, Dennisdhilak
    Mehta, Dhruv
    Raja, Siva
    Murthy, Sudhish
    Sanaka, Madhusudhan R.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (03): : 700 - 707
  • [49] Single-step transvenous extraction of a passive fixation lead with delayed perforation of the right ventricle
    Lopes, Luis Rocha
    Brandao, Luis
    Carrageta, Manuel
    EUROPACE, 2007, 9 (08): : 672 - 673
  • [50] Timing of esophageal stent placement and outcomes in patients with esophageal perforation: a single-center experience
    Udayakumar Navaneethan
    Vennisvasanth Lourdusamy
    Sudhir Duvuru
    Dennisdhilak Lourdusamy
    Dhruv Mehta
    Siva Raja
    Sudhish Murthy
    Madhusudhan R. Sanaka
    Surgical Endoscopy, 2015, 29 : 700 - 707