Single center experience with the novel rotating dilator sheath TightRail™ Sub-C in transvenous lead extraction

被引:0
|
作者
Frei, Celine [1 ]
Hofer, Daniel [1 ]
Jan, Steffel [1 ]
Grebmer, Christian [2 ]
Breitenstein, Alexander [1 ,3 ]
机构
[1] Univ Hosp Zurich, Univ Heart Ctr, Dept Cardiol, Electrophysiol, Zurich, Switzerland
[2] Cantonal Hosp Lucerne, Dept Cardiol, Luzern, Switzerland
[3] Univ Hosp Zurich, Univ Heart Ctr Zurich, Dept Cardiol, Raemistr 100, CH-8091 Zurich, Switzerland
关键词
cardiovascular implantable electronic device; rotational sheath; TightRailTM Sub-C; transvenous lead extraction; OUTCOMES; PATIENT; SYSTEM;
D O I
10.1111/jce.15970
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Transvenous lead extraction has become a frequent procedure in the context of device lead management and various tools are available. The aim of this study was to investigate the efficacy and safety of the novel short rotating dilator sheath TightRail (TM) Sub-C (Sub-C) in transvenous lead extraction. Methods: For this retrospective single-center analysis, we included consecutive patients undergoing transvenous lead extraction using the Sub-C from January 2018 until February 2020 at the University Heart Center Zurich. Results: A total of 87 leads were extracted within 45 patients using the Sub-C extraction sheath. The mean dwell time of the leads was 112 +/- 9.1 months. Complete procedural success was achieved in 95.6% (43/45) and clinical procedural success in 97.8% (44/45). Two major complications (4.4%, 2/45) occurred, but neither was directly related to the Sub-C. Conclusion: This retrospective single-center analysis suggests that transvenous lead extraction with a routine use of the TightRail (TM) Sub-C extraction sheath is a safe strategy resulting in high success rates that may offer useful theoretical benefits. Future studies are needed to evaluate the incremental benefit of a routine use of short extraction sheaths including the Sub-C during TLE procedures.
引用
收藏
页码:1738 / 1743
页数:6
相关论文
共 50 条
  • [1] Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction
    Aytemir, Kudret
    Yorgun, Hikmet
    Canpolat, Ugur
    Sahiner, M. Levent
    Kaya, Ergun Baris
    Evranos, Banu
    Ozer, Necla
    EUROPACE, 2016, 18 (07): : 1043 - 1048
  • [2] Initial experience with the Tightrail rotating mechanical dilator sheath for transvenous lead extraction: safety and efficacy
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Sahiner, M. L.
    Kaya, E. B.
    Evranos, B.
    Ozer, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 821 - 822
  • [3] Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients
    Ji-Hoon Choi
    Seung-Jung Park
    Hye Ree Kim
    Hee-Jin Kwon
    Kyoung-Min Park
    Young Keun On
    June Soo Kim
    Ju Youn Kim
    Won Young Jung
    Scientific Reports, 11
  • [4] Comparison between TightRail rotating dilator sheath and GlideLight laser sheath for transvenous lead extraction
    Qin, Dingxin
    Chokshi, Moulin
    Sabeh, Mohamad Khaled
    Maan, Abhishek
    Bapat, Aneesh
    Bode, Weeranun D.
    Hanley, Alan
    Hucker, William J.
    Ng, Chee Yuan
    Funamoto, Masaki
    Barrett, Conor D.
    Mela, Theofanie
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (05): : 895 - 902
  • [5] Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients
    Choi, Ji-Hoon
    Park, Seung-Jung
    Kim, Hye Ree
    Kwon, Hee-Jin
    Park, Kyoung-Min
    On, Young Keun
    Kim, June Soo
    Kim, Ju Youn
    Jung, Won Young
    SCIENTIFIC REPORTS, 2022, 11 (01)
  • [6] Outcomes of transvenous lead extraction using the TightRail™ mechanical rotating dilator sheath and excimer laser sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Patricia
    Cerbie, Claire
    Guifarro, Angello
    Lesiczka, Magdalena
    Holshouser, John W.
    Madjarov, Jeko
    Love, Charles
    Mehta, Rohit
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (07) : 1969 - 1978
  • [7] Use of the new rotating dilator sheath TightRail™ for lead extraction: A bicentric experience
    Mazzone, Patrizio
    Melillo, Francesco
    Radinovic, Andrea
    Marzi, Alssandra
    Paglino, Gabriele
    Della Bella, Paolo
    Mascioli, Giosue
    JOURNAL OF ARRHYTHMIA, 2020, 36 (02) : 343 - 350
  • [8] Comparison of Outcomes of Transvenous Lead Extraction Using an Excimer Laser Sheath vs the Tightrail Rotating Dilator Sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Tricia
    Cerbie, Claire
    Lesiczka, Magdalena
    Holshouser, John W.
    Mehta, Rohit
    CIRCULATION, 2019, 140
  • [9] Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
    Mammadli, Anar
    Vurgun, Veysel Kutay
    Yildirim, Onur
    Altin, Ali Timucin
    Candemir, Basar
    Akyurek, Omer
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2018, 46 (01): : 54 - 56
  • [10] Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience
    Kocabas, Ugur
    Duygu, Hamza
    Eren, Nihan Kahya
    Akyildiz, Zehra Ilke
    Ozyildirim, Serhan
    Tuluce, Selcen Yakar
    Kiris, Tuncay
    Nazli, Cem
    SPRINGERPLUS, 2016, 5