Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients

被引:3
|
作者
Choi, Ji-Hoon [1 ]
Park, Seung-Jung [1 ]
Kim, Hye Ree [1 ]
Kwon, Hee-Jin [1 ]
Park, Kyoung-Min [1 ]
On, Young Keun [1 ]
Kim, June Soo [1 ]
Kim, Ju Youn [1 ]
Jung, Won Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Div Cardiol,Dept Med,Heart Vasc & Stroke Inst, 81 Irwon Ro, Seoul 06351, South Korea
关键词
IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; TRICUSPID REGURGITATION; RISK-FACTORS; WORLD SURVEY; PACEMAKER; SOCIETY; ASSOCIATION; EXPERIENCE; OUTCOMES; TRENDS;
D O I
10.1038/s41598-021-99901-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The need for transvenous lead extraction (TLE) is increasing worldwide including in Asia-Pacific regions. However, supporting evidence for TightRail, a relatively new rotating mechanical dilator sheath, is still lacking in Asian patients. The efficacy and safety of TLE using TightRail performed between March 2018 and June 2021 were evaluated in 86 consecutive patients with 131 leads. The mean lead age was 11.7 +/- 7.3 (range, 1.0-41.4) years. Clinical and complete procedural success using TightRail were achieved in 93.0% and 89.5% of 86 patients, respectively, with 6 min of median fluoroscopic time and 9.3% of major complication rate: death (1.2%), cardiac tamponade (3.5%), severe tricuspid regurgitation (3.5%), and stroke (1.2%). However, in 46 patients with longest lead age <= 10 years, clinical/complete success and major cardiac complication rates turned out better as 97.8%, 95.7%, and 2.2%, respectively. Additionally, when patients were divided into 3 groups: the first 28, second 29, and the last 29 patients, there was a clear trend toward better efficacy and safety outcomes with more experience with TightRail (P-trend < 0.05). Longest lead age > 10 years was closely associated with TLE-related major cardiac complication (P = 0.046) with 85.7% sensitivity, 57.0% specificity, 15.0% positive predictive value, and 97.8% negative predictive values. In conclusion, TLE using TightRail may be effectively and safely performed by experienced operators for Asian patients with the longest lead age <= 10 years. However, as TightRail is a potentially aggressive tool, special attention should be paid to patients with longer lead dwelling times (e.g., > 10 years).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients
    Ji-Hoon Choi
    Seung-Jung Park
    Hye Ree Kim
    Hee-Jin Kwon
    Kyoung-Min Park
    Young Keun On
    June Soo Kim
    Ju Youn Kim
    Won Young Jung
    Scientific Reports, 11
  • [2] Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction
    Aytemir, Kudret
    Yorgun, Hikmet
    Canpolat, Ugur
    Sahiner, M. Levent
    Kaya, Ergun Baris
    Evranos, Banu
    Ozer, Necla
    EUROPACE, 2016, 18 (07): : 1043 - 1048
  • [3] Outcomes of transvenous lead extraction using the TightRail™ mechanical rotating dilator sheath and excimer laser sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Patricia
    Cerbie, Claire
    Guifarro, Angello
    Lesiczka, Magdalena
    Holshouser, John W.
    Madjarov, Jeko
    Love, Charles
    Mehta, Rohit
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (07) : 1969 - 1978
  • [4] Initial experience with the Tightrail rotating mechanical dilator sheath for transvenous lead extraction: safety and efficacy
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Sahiner, M. L.
    Kaya, E. B.
    Evranos, B.
    Ozer, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 821 - 822
  • [5] Comparison between TightRail rotating dilator sheath and GlideLight laser sheath for transvenous lead extraction
    Qin, Dingxin
    Chokshi, Moulin
    Sabeh, Mohamad Khaled
    Maan, Abhishek
    Bapat, Aneesh
    Bode, Weeranun D.
    Hanley, Alan
    Hucker, William J.
    Ng, Chee Yuan
    Funamoto, Masaki
    Barrett, Conor D.
    Mela, Theofanie
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (05): : 895 - 902
  • [6] Comparison of Outcomes of Transvenous Lead Extraction Using an Excimer Laser Sheath vs the Tightrail Rotating Dilator Sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Tricia
    Cerbie, Claire
    Lesiczka, Magdalena
    Holshouser, John W.
    Mehta, Rohit
    CIRCULATION, 2019, 140
  • [7] Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
    Mammadli, Anar
    Vurgun, Veysel Kutay
    Yildirim, Onur
    Altin, Ali Timucin
    Candemir, Basar
    Akyurek, Omer
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2018, 46 (01): : 54 - 56
  • [8] Single center experience with the novel rotating dilator sheath TightRail™ Sub-C in transvenous lead extraction
    Frei, Celine
    Hofer, Daniel
    Jan, Steffel
    Grebmer, Christian
    Breitenstein, Alexander
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (08) : 1738 - 1743
  • [9] Use of the new rotating dilator sheath TightRail™ for lead extraction: A bicentric experience
    Mazzone, Patrizio
    Melillo, Francesco
    Radinovic, Andrea
    Marzi, Alssandra
    Paglino, Gabriele
    Della Bella, Paolo
    Mascioli, Giosue
    JOURNAL OF ARRHYTHMIA, 2020, 36 (02) : 343 - 350
  • [10] CURRENT PRACTICE AND APPLICATIONS OF TRANSVENOUS LEAD EXTRACTION USING EVOLUTION® MECHANICAL DILATOR SHEATH
    Oto, A.
    Aytemir, K.
    Canpolat, U.
    Yorgun, H.
    Kaya, E. B.
    Sahiner, L.
    Asil, S.
    Yalcin, U.
    Dural, M.
    Sunman, H.
    Kabakci, G.
    Tokgozoglu, L.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S48 - S49