Comparison between peak expiratory flow and FEV1 measurements on a home spirometer and on a pneumotachograph in children with asthma

被引:23
|
作者
Brouwer, Alwin F. J.
Roorda, Ruurd Jan
Brand, Paul L. P.
机构
[1] Princess Amalia Childrens Clin, Isala Klinieken, NL-8000 GK Zwolle, Netherlands
[2] St Anna Zorggroep, Geldrop, Netherlands
关键词
accuracy; childhood asthma; home spirometer; lung function; peak flow;
D O I
10.1002/ppul.20660
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The accuracy of electronic portable home spirometers has been demonstrated in vitro using computer-based waveforms. We assessed the agreement in vivo between measurements of lung function on an electronic spirometer (Koko Peak Pro) and those obtained by the gold standard, a hospital lung function laboratory pneumotachograph. Methods: Fifty stable asthmatic children (33 boys), aged 6-17 years, performed peak expiratory flow (PEF) and forced expiratory volume in 1 see (FEV1) measurements according to international guidelines on a portable home spirometer and on the hospital pneumotachograph in random order. All measurements complied to standard quality criteria. The PEF and FEV, values recorded with the home spirometer and on the hospital pneumotachograph were compared. Results: All children performed reproducible high-quality measurements on both spirometers. PEF values on the home spirometer were considerably lower than on the laboratory pneumotachograph (95% CI for difference in PEF 14-30 L/min; P<0.0001). Individual differences in PEF between the two devices could be >100 L/min. The FEV1 values were slightly, but significantly, lower on the home spirometer (95% CI for difference in FEV1 0.02-0.1 L; P 0.0018). Conclusions: A home spirometer provides reproducible and quality acceptable measures in children with asthma when performed under professional supervision and encouragement. Mean PEF and FEV, values recorded on this home spirometer are significantly lower than those on a hospital pneumotachograph, and individual differences may be large. Therefore, home spirometry may not be interchanged with pneumotachography in a lung function laboratory.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 50 条
  • [41] Deriving a change score for FEV1 for children with asthma
    Filipow, Nicole
    Turner, Stephen
    Chang, Anne
    Petsky, Helen
    Frischer, Thomas
    Szefler, Stanley
    Stanojevic, Sanja
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [42] Bronchodilators in school children with asthma and normal FEV1
    Kamenov, Svetlana
    Kamenov, Aleksandar
    Kamenov, Borislav
    Cekic, Snezana
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [43] Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry
    Brouwer, A. F. J.
    Roorda, R. J.
    Duiverman, E. J.
    Brand, P. L. P.
    EUROPEAN RESPIRATORY JOURNAL, 2008, 32 (05) : 1262 - 1268
  • [44] Relative value of FEV1 and FEV1%FVC in evaluating control of asthma in children and young adults
    Ciolkowski, J.
    Henryk, M.
    Stasiowska, B.
    ALLERGY, 2009, 64 : 303 - 303
  • [45] Portable electronic spirometry with peak flow and FEV1 memory
    Barrabe, P
    Choudat, D
    Dessanges, JF
    REVUE DES MALADIES RESPIRATOIRES, 1999, 16 (03) : 402 - 403
  • [46] A comparative trial of personal electronic FEV1/Peak Flow Meters and a standard Peak Flow Meter in children.
    Carel, K.
    Rabinovitch, N.
    Strand, M.
    Gleason, M.
    Mault, J. R.
    Liu, A. H.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2007, 98 (01) : A64 - A64
  • [47] MEASUREMENTS OF MORNINGS AND EVENING AIR-FLOW GROSSLY UNDERESTIMATE THE CIRCADIAN VARIABILITY OF FEV(1) AND PEAK EXPIRATORY FLOW-RATE IN ASTHMA
    DALONZO, GE
    STEINIJANS, VW
    KELLER, A
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (03) : 1097 - 1099
  • [48] INFLUENCE OF BODY COMPOSITION ON FEV(1), FEV(6), FEV(1)/FEV(6) AND PEAK EXPIRATORY FLOW RATE
    Djeddi, D.
    Vanrenterghem, A.
    Kongolo, G.
    Leke, A.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2010, 50 : E176 - E177
  • [49] Pilot study: correlation between FEV1 and hand held spirometry (Peak Flow)
    Rushton, Cherie
    Robertson, Leeah
    Matthews, Nick
    Alfred, Arun
    BONE MARROW TRANSPLANTATION, 2018, 53 : 871 - 871
  • [50] PEAK EXPIRATORY FLOW MEASUREMENTS IN YOUNG-CHILDREN - COMPARISON OF 4 PORTABLE PEAK FLOW METERS
    TRUONG, M
    INIGUEZ, JL
    CHOUHOU, D
    DESSANGE, JF
    GENDREL, D
    CHAUSSAIN, M
    ARCHIVES DE PEDIATRIE, 1995, 2 (04): : 324 - 327