Comparison between peak expiratory flow and FEV1 measurements on a home spirometer and on a pneumotachograph in children with asthma

被引:23
|
作者
Brouwer, Alwin F. J.
Roorda, Ruurd Jan
Brand, Paul L. P.
机构
[1] Princess Amalia Childrens Clin, Isala Klinieken, NL-8000 GK Zwolle, Netherlands
[2] St Anna Zorggroep, Geldrop, Netherlands
关键词
accuracy; childhood asthma; home spirometer; lung function; peak flow;
D O I
10.1002/ppul.20660
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The accuracy of electronic portable home spirometers has been demonstrated in vitro using computer-based waveforms. We assessed the agreement in vivo between measurements of lung function on an electronic spirometer (Koko Peak Pro) and those obtained by the gold standard, a hospital lung function laboratory pneumotachograph. Methods: Fifty stable asthmatic children (33 boys), aged 6-17 years, performed peak expiratory flow (PEF) and forced expiratory volume in 1 see (FEV1) measurements according to international guidelines on a portable home spirometer and on the hospital pneumotachograph in random order. All measurements complied to standard quality criteria. The PEF and FEV, values recorded with the home spirometer and on the hospital pneumotachograph were compared. Results: All children performed reproducible high-quality measurements on both spirometers. PEF values on the home spirometer were considerably lower than on the laboratory pneumotachograph (95% CI for difference in PEF 14-30 L/min; P<0.0001). Individual differences in PEF between the two devices could be >100 L/min. The FEV1 values were slightly, but significantly, lower on the home spirometer (95% CI for difference in FEV1 0.02-0.1 L; P 0.0018). Conclusions: A home spirometer provides reproducible and quality acceptable measures in children with asthma when performed under professional supervision and encouragement. Mean PEF and FEV, values recorded on this home spirometer are significantly lower than those on a hospital pneumotachograph, and individual differences may be large. Therefore, home spirometry may not be interchanged with pneumotachography in a lung function laboratory.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 50 条
  • [21] Relation of changes in peak expiratory flow (PEF) and forced expiratory volume in 1 s (FEV1) during bronchoconstriction
    Csonka, Leon L.
    Tikkakoski, Antti
    Vuotari, Liisa
    Karjalainen, Jussi
    Lehtimaki, Lauri
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2024, 44 (06) : 447 - 453
  • [22] Relationship between FEV1/FVC and age in children with asthma
    Ahmed, Amal
    Brown, Amy
    Pollack, Yehudit
    Vazhappilly, Joshua
    Perry, Carrighan
    Thomas, Erica R.
    Krishnan, Sankaran
    Dozor, Allen J.
    PEDIATRIC PULMONOLOGY, 2024, 59 (05) : 1402 - 1409
  • [23] COMPARISON OF PEAK EXPIRATORY FLOW-RATE AND FEV1 IN ASSESSING BRONCHOMOTOR TONE AFTER CHALLENGES WITH OCCUPATIONAL SENSITIZERS
    BERUBE, D
    CARTIER, A
    LARCHEVEQUE, J
    GHEZZO, H
    MALO, JL
    CHEST, 1991, 99 (04) : 831 - 836
  • [24] Comparisons of peak diurnal expiratory flow variation, postbronchodilator FEV1 responses, and methacholine inhalation challenges in the evaluation of suspected asthma
    Goldstein, MF
    Veza, BA
    Dunsky, EH
    Dvorin, DJ
    Belecanech, GA
    Haralabatos, IC
    CHEST, 2001, 119 (04) : 1001 - 1010
  • [25] Raised FeNO is associated with lower FEV1 and FEV1/FVC in children with asthma
    Lo, David
    Danvers, Lesley
    Roland, Damian
    Richardson, Matthew
    Yang, Yaling
    Beardsmore, Caroline
    Wilson, Andrew
    Gaillard, Erol
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [27] Difficulty in obtaining peak expiratory flow measurements in children with acute asthma
    Gorelick, MH
    Stevens, MW
    Schultz, T
    Scribano, PV
    PEDIATRIC EMERGENCY CARE, 2004, 20 (01) : 22 - 26
  • [28] FEV1 AND PEAK FLOW - WRIGHT AND THE MINI METERS
    CONNOLLY, CK
    RESPIRATORY MEDICINE, 1992, 86 (06) : 451 - 453
  • [29] Peak expiratory flow at increased barometric pressure: comparison of peak flow meters and volumetric spirometer
    Thomas, PS
    Ng, C
    Bennett, M
    CLINICAL SCIENCE, 2000, 98 (01) : 121 - 124
  • [30] Change in FEV1 and FENO Measurements as Predictors of Future Asthma Outcomes in Children
    Fielding, Shona
    Pijnenburg, Marielle
    de Jongste, Johan C.
    Pike, Katharine C.
    Roberts, Graham
    Petsky, Helen
    Chang, Anne B.
    Fritsch, Maria
    Frischer, Thomas
    Szefler, Stanley
    Gergen, Peter
    Vermeulen, Francoise
    Vael, Robin
    Turner, Steve
    CHEST, 2019, 155 (02) : 331 - 341