Associating Automated Breast Ultrasound (ABUS) and Digital Breast Tomosynthesis (DBT) with Full-Field Digital Mammography (FFDM) in Clinical Practice in Cases of Women with Dense Breast Tissue

被引:2
|
作者
Boca , Ioana [1 ]
Ciurea, Anca Ileana [1 ]
Vesa, Stefan Cristian [2 ]
Ciortea, Cristiana Augusta [3 ]
Dudea, Sorin Marian [1 ]
Manole, Simona [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Radiol, Cluj Napoca 400012, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Pharmacol Toxicol & Clin Pharmacol, Cluj Napoca 400012, Romania
[3] Emergency Cty Hosp, Dept Radiol, Cluj Napoca 400006, Romania
关键词
full-field digital mammography (FFDM); digital breast tomosynthesis (DBT); automated breast ultrasound (ABUS); dense breast tissue; CANCER DETECTION; 2-VIEW; READER; VOLUME;
D O I
10.3390/diagnostics12020459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to evaluate the value of full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in the diagnosis of breast cancer compared to FFDM associated with digital breast tomosynthesis (DBT). Methods: This retrospective study included 50 female patients with a denser framework of connective tissue fibers, characteristic of young women who underwent FFDM, DBT, handheld ultrasound (HHUS), and ABUS between January 2017 and October 2018. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of FFDM+ABUS were 81.82% (95% CI [48.22-97.72]), 89.74% (95% CI [75.78-97.13]), 69.23% (95% CI [46.05-85.57]), 94.59% (95% CI [83.26-98.40]), and 88% (95% CI [75.69-95.47]), while for FFDM+DBT, the values were as follows: 91.67% (95% CI [61.52-99.79]), 71.79% (95% CI [55.13-85.00]), 50% (95% CI [37.08-62.92]), 96.55% (95% CI [80.93-99.46]), 76.47% (95% CI [62.51-87.21]). We found an almost perfect agreement between the two readers regarding FFDM associated with ABUS, and substantial agreement regarding FFDM+DBT, with a kappa coefficient of 0.896 and 0.8, respectively; p < 0.001. Conclusions: ABUS and DBT are suitable as additional diagnostic imaging techniques to FFDM in women at an intermediate risk of developing breast cancer through the presence of dense breast tissue. In this study, DBT reduced the number of false negative results, while the use of ABUS resulted in an increase in specificity.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Lesion-specific exposure parameters for breast cancer diagnosis on digital breast tomosynthesis and full-field digital mammography
    Ma, Le
    Liu, Hui
    Lin, Xiaojia
    Cai, Yuxing
    Zhang, Ling
    Chen, Weiguo
    Qin, Genggeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 77
  • [42] AN OBSERVER PERFORMANCE STUDY COMPARING THE INTERPRETATION OF FULL-FIELD DIGITAL MAMMOGRAPHY WITH DIGITAL BREAST TOMOSYNTHESIS
    Wasan, Rema K.
    Iqbal, Asif
    Evans, David R.
    Peacock, Clare
    Morel, Juliet C.
    Douiri, Abdel
    Michell, Michael J.
    EJC SUPPLEMENTS, 2010, 8 (06): : 32 - 32
  • [43] Size and Shape of Spherical Objects on Full-Field Digital Mammography and Digital Breast Tomosynthesis Images
    Yatake, Hidetoshi
    Sawai, Yuka
    Kozuka, Takahiro
    Takeda, Yoshihiro
    Kajihara, Mariko
    Katsuda, Toshizo
    Gotanda, Rumi
    Gotanda, Tatsuhiro
    Abe, Shuji
    Shimada, Makoto
    Tanki, Nobuyoshi
    Nishi, Toshio
    Inaji, Hideo
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 45 - 48
  • [44] Comparing Tumor Characteristics and Rates of Breast Cancers Detected by Screening Digital Breast Tomosynthesis and Full-Field Digital Mammography
    Dang, Pragya A.
    Wang, Aijia
    Senapati, Gunjan M.
    Ip, Ivan K.
    Lacson, Ronilda
    Khorasani, Ramin
    Giess, Catherine S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (03) : 701 - 706
  • [45] Combinations of Digital Breast Tomosynthesis and Full-field Digital Mammography for Different Density Types of Breasts
    Chen, Qiong
    Pan, Xin
    Xu, Junfeng
    Ying, Weifeng
    Hou, Yuyu
    Lu, Ming
    An, Dongqin
    Peng, Weijun
    CURRENT MEDICAL IMAGING, 2024, 20
  • [46] There Is No Way That the Cancer Detection Rate for Full-Field Digital Mammography Is the Same as for Digital Breast Tomosynthesis
    Kopans, Daniel B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (01) : W46 - W46
  • [47] Comparison of Mean Glandular Dose between Full-Field Digital Mammography and Digital Breast Tomosynthesis
    Teoh, Kar Choon
    Manan, Hanani Abdul
    Norsuddin, Norhashimah Mohd
    Rizuana, Iqbal Hussain
    HEALTHCARE, 2021, 9 (12)
  • [48] Performance of full-field digital mammography versus digital breast
    Wang, Mengru
    Zhuang, Shan
    Sheng, Liuli
    Zhao, Yu Nian
    Shen, Wenrong
    PRECISION MEDICAL SCIENCES, 2022, 11 (02): : 56 - 61
  • [49] A Prospective Study of Automated Breast Ultrasound Screening of Women with Dense Breasts in a Digital Breast Tomosynthesis-based Practice
    Chough, Denise M.
    Berg, Wendie A.
    Bandos, Andriy, I
    Rathfon, Grace Y.
    Hakim, Christiane M.
    Lu, Amy H.
    Gizienski, Terri-Ann
    Ganott, Marie A.
    Gur, David
    JOURNAL OF BREAST IMAGING, 2020, 2 (02) : 125 - 133
  • [50] Diagnostic Performance of Digital Breast Tomosynthesis for Breast Suspicious Calcifications From Various Populations: A Comparison With Full-field Digital Mammography
    Li, Juntao
    Zhang, Hengwei
    Jiang, Hui
    Guo, Xuhui
    Zhang, Yinli
    Qi, Dan
    Guan, Jitian
    Liu, Zhenzhen
    Wu, Erxi
    Luo, Suxia
    COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2019, 17 : 82 - 89