Associating Automated Breast Ultrasound (ABUS) and Digital Breast Tomosynthesis (DBT) with Full-Field Digital Mammography (FFDM) in Clinical Practice in Cases of Women with Dense Breast Tissue

被引:2
|
作者
Boca , Ioana [1 ]
Ciurea, Anca Ileana [1 ]
Vesa, Stefan Cristian [2 ]
Ciortea, Cristiana Augusta [3 ]
Dudea, Sorin Marian [1 ]
Manole, Simona [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Radiol, Cluj Napoca 400012, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Pharmacol Toxicol & Clin Pharmacol, Cluj Napoca 400012, Romania
[3] Emergency Cty Hosp, Dept Radiol, Cluj Napoca 400006, Romania
关键词
full-field digital mammography (FFDM); digital breast tomosynthesis (DBT); automated breast ultrasound (ABUS); dense breast tissue; CANCER DETECTION; 2-VIEW; READER; VOLUME;
D O I
10.3390/diagnostics12020459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to evaluate the value of full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in the diagnosis of breast cancer compared to FFDM associated with digital breast tomosynthesis (DBT). Methods: This retrospective study included 50 female patients with a denser framework of connective tissue fibers, characteristic of young women who underwent FFDM, DBT, handheld ultrasound (HHUS), and ABUS between January 2017 and October 2018. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of FFDM+ABUS were 81.82% (95% CI [48.22-97.72]), 89.74% (95% CI [75.78-97.13]), 69.23% (95% CI [46.05-85.57]), 94.59% (95% CI [83.26-98.40]), and 88% (95% CI [75.69-95.47]), while for FFDM+DBT, the values were as follows: 91.67% (95% CI [61.52-99.79]), 71.79% (95% CI [55.13-85.00]), 50% (95% CI [37.08-62.92]), 96.55% (95% CI [80.93-99.46]), 76.47% (95% CI [62.51-87.21]). We found an almost perfect agreement between the two readers regarding FFDM associated with ABUS, and substantial agreement regarding FFDM+DBT, with a kappa coefficient of 0.896 and 0.8, respectively; p < 0.001. Conclusions: ABUS and DBT are suitable as additional diagnostic imaging techniques to FFDM in women at an intermediate risk of developing breast cancer through the presence of dense breast tissue. In this study, DBT reduced the number of false negative results, while the use of ABUS resulted in an increase in specificity.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [32] Comparison of screening full-field digital mammography and digital breast tomosynthesis technical recalls
    Salkowski, Lonie R.
    Elezaby, Mai
    Fowler, Amy M.
    Burnside, Elizabeth
    Woods, Ryan W.
    Strigel, Roberta M.
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [33] UTILIZATION OF DIGITAL BREAST TOMOSYNTHESIS OR BREAST ULTRASOUND IN CONJUNCTION WITH FULL-FIELD DIGITAL MAMMOGRAPHY IN COMMERCIALLY-INSURED WOMEN: A CLAIMS-BASED ANALYSIS
    Bonafede, M.
    Miller, J. D.
    Pohlman, S. K.
    Troeger, K. A.
    VALUE IN HEALTH, 2019, 22 : S57 - S57
  • [34] Double reading of automated breast ultrasound with digital mammography or digital breast tomosynthesis for breast cancer screening
    Lee, Janie M.
    Partridge, Savannah C.
    Liao, Geraldine J.
    Hippe, Daniel S.
    Kim, Adrienne E.
    Lee, Christoph, I
    Rahbar, Habib
    Scheel, John R.
    Lehman, Constance D.
    CLINICAL IMAGING, 2019, 55 : 119 - 125
  • [35] A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis
    Michell, M. J.
    Iqbal, A.
    Wasan, R. K.
    Evans, D. R.
    Peacock, C.
    Lawinski, C. P.
    Douiri, A.
    Wilson, R.
    Whelehan, P.
    CLINICAL RADIOLOGY, 2012, 67 (10) : 976 - 981
  • [36] A COMPARISON OF DIGITAL BREAST TOMOSYNTHESIS AND FULL FIELD DIGITAL MAMMOGRAPHY IN THE DETECTION OF BREAST CANCER
    Moradzadeh, A.
    Bassett, L. W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (01) : 128 - 128
  • [37] Breast positioning system for full field digital mammography and digital breast tomosynthesis system
    Varjonen, Mari
    Pamilo, Martti
    Hokka, Pirjo
    Hokkanen, Riina
    Strommer, Pekka
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [38] Dense Breast Ultrasound Screening After Digital Mammography Versus After Digital Breast Tomosynthesis
    Dibble, Elizabeth H.
    Singer, Tisha M.
    Jimoh, Nneka
    Baird, Grayson L.
    Lourenco, Ana P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (06) : 1397 - 1402
  • [39] Clinical utility of the radiation dose management system for full field digital mammography (FFDM): In Asian women with dense breast tissue.
    Kang, Bong Joo
    Baek, Ji Eun
    Lee, Hyun Sil
    Kim, Sung Hun
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (28)
  • [40] Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts
    Ha, Su Min
    Yi, Ann
    Yim, Dahae
    Jang, Myoung-jin
    Kwon, Bo Ra
    Shin, Sung Ui
    Lee, Eun Jae
    Lee, Soo Hyun
    Moon, Woo Kyung
    Chang, Jung Min
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (04) : 274 - 283