Associating Automated Breast Ultrasound (ABUS) and Digital Breast Tomosynthesis (DBT) with Full-Field Digital Mammography (FFDM) in Clinical Practice in Cases of Women with Dense Breast Tissue

被引:2
|
作者
Boca , Ioana [1 ]
Ciurea, Anca Ileana [1 ]
Vesa, Stefan Cristian [2 ]
Ciortea, Cristiana Augusta [3 ]
Dudea, Sorin Marian [1 ]
Manole, Simona [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Radiol, Cluj Napoca 400012, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Pharmacol Toxicol & Clin Pharmacol, Cluj Napoca 400012, Romania
[3] Emergency Cty Hosp, Dept Radiol, Cluj Napoca 400006, Romania
关键词
full-field digital mammography (FFDM); digital breast tomosynthesis (DBT); automated breast ultrasound (ABUS); dense breast tissue; CANCER DETECTION; 2-VIEW; READER; VOLUME;
D O I
10.3390/diagnostics12020459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to evaluate the value of full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in the diagnosis of breast cancer compared to FFDM associated with digital breast tomosynthesis (DBT). Methods: This retrospective study included 50 female patients with a denser framework of connective tissue fibers, characteristic of young women who underwent FFDM, DBT, handheld ultrasound (HHUS), and ABUS between January 2017 and October 2018. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of FFDM+ABUS were 81.82% (95% CI [48.22-97.72]), 89.74% (95% CI [75.78-97.13]), 69.23% (95% CI [46.05-85.57]), 94.59% (95% CI [83.26-98.40]), and 88% (95% CI [75.69-95.47]), while for FFDM+DBT, the values were as follows: 91.67% (95% CI [61.52-99.79]), 71.79% (95% CI [55.13-85.00]), 50% (95% CI [37.08-62.92]), 96.55% (95% CI [80.93-99.46]), 76.47% (95% CI [62.51-87.21]). We found an almost perfect agreement between the two readers regarding FFDM associated with ABUS, and substantial agreement regarding FFDM+DBT, with a kappa coefficient of 0.896 and 0.8, respectively; p < 0.001. Conclusions: ABUS and DBT are suitable as additional diagnostic imaging techniques to FFDM in women at an intermediate risk of developing breast cancer through the presence of dense breast tissue. In this study, DBT reduced the number of false negative results, while the use of ABUS resulted in an increase in specificity.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of radiation doses between diagnostic full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT): a clinical study
    Asbeutah, Akram M.
    AlMajran, Abdullah A.
    Brindhaban, Ajit
    Asbeutah, Saad A.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (03) : 185 - 192
  • [2] Automated Breast Density Assessment for Full-Field Digital Mammography and Digital Breast Tomosynthesis
    Jiang, Shu
    Bennett, Debbie L.
    Chen, Simin
    Toriola, Adetunji T.
    Colditz, Graham A.
    CANCER PREVENTION RESEARCH, 2025, 18 (01) : 23 - 29
  • [3] UTILIZATION AND COSTS OF DIGITAL BREAST TOMOSYNTHESIS OR BREAST ULTRASOUND IN CONJUNCTION WITH FULL-FIELD DIGITAL MAMMOGRAPHY
    Bonafede, M. M.
    Miller, J. D.
    Dabbous, F.
    Pohlman, S. K.
    Troeger, K. A.
    VALUE IN HEALTH, 2017, 20 (05) : A243 - A244
  • [4] Digital full-field mammography (FFDM) versus digital breast tomosynthesis (DBT) Which system increases the quality of preparation radiography?
    Urban, H.
    Bauerschmitz, G. J.
    Gallwas, J.
    Wienbeck, S.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2022, 82 (10) : E175 - E175
  • [5] Local diagnostic reference levels (LDRLs) for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) procedures in Morocco
    Talbi, Mohammed
    El Mansouri, M'hamed
    Nhila, Oussama
    Tahiri, Zakaria
    Eddaoui, Khalida
    Khalis, Mohammed
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (02) : 242 - 247
  • [6] A comparison of full-field digital mammography (FFDM) with digital breast tomosynthesis (DBT) in the detection of microcalcifications by correlating mammographic and pathologic findings
    Farghadani, Maryam
    Ghadiri-faraz, Bahar
    Riahinezhad, Maryam
    Sarami, Sahar
    IMMUNOPATHOLOGIA PERSA, 2024, 10 (02):
  • [7] Characterization of breast masses: a comparative study between automated breast ultrasound (ABUS) and digital breast tomosynthesis (DBT)
    Hashem, Lamiaa Mohamed Bassam
    Ali, Reham Hussein Mohamed
    Helal, Maha Hussein
    Gemeae, Emad ELdin E. L.
    Moustafa, Amr Farouk Ibrahim
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [8] Characterization of breast masses: a comparative study between automated breast ultrasound (ABUS) and digital breast tomosynthesis (DBT)
    Lamiaa Mohamed Bassam Hashem
    Reham Hussein Mohamed Ali
    Maha Hussein Helal
    Emad ELdin E. L. Gemeae
    Amr Farouk Ibrahim Moustafa
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [9] Assessment of local diagnostic reference levels (LDRLS) for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) mammography in Tamil Nadu, India
    Adhimoolam, Saravana Kumar
    Kumar, Sudhir
    Manojkumar, Thangavel
    Devanand, Bala Lakshmoji
    Elango, Nagappan
    Govindarajan, Nagarajarao
    Sapra, Balvinder Kaur
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (19) : 1926 - 1932
  • [10] Invasive breast cancer: Digital breast tomosynthesis versus full-field digital mammography
    Hwang, Esther
    Szabo, Janet
    Mehta, Anita
    Margolies, Laurie
    APPLIED RADIOLOGY, 2016, 45 (12) : 32 - 34