Growth and partial discharge characteristics of DC electrical trees in cross-linked polyethylene

被引:21
|
作者
Liu, Hechen [1 ]
Zhang, Mingjia [1 ]
Liu, Yunpeng [1 ]
Xu, Xiaobin [1 ]
Liu, Aijing [1 ]
机构
[1] North China Elect Power Univ, Hebei Prov Key Lab Power Transmiss Equipment Secu, 619 Yonghua North St, Baoding City 071003, Peoples R China
关键词
DC electrical tree; growth properties; cross-linked polyethylene; partial discharge; SILICONE-RUBBER; GROUNDED DC; INITIATION; AC; DEPENDENCE; FEATURES; XLPE;
D O I
10.1109/TDEI.2019.008265
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the present study, the growth and partial discharges properties of DC electrical trees in cross-linked polyethylene (XLPE) were investigated under positive and negative DC voltages. The obtained results revealed that the voltage rise exerted significant influences on growth properties of DC trees. In either polarity, DC electrical trees grew rapidly during rising voltage and maintained the rapid growth for a certain time after DC voltage reached a constant value. The growth rate of positive DC electrical trees was quite faster than that of negative ones, and channel breakdown mainly occurred in positive ones. Although the growth rates of positive and negative DC electrical trees were different, their shapes were similar (both were branch-like electrical trees with one or two main branches). Self-healing usually occurred in negative DC electrical trees, thus electrical tree branches gradually disappeared under the application of steady DC voltage or when the voltage was off. Partial discharges mainly occurred at the beginning of electrical tree growth; however, the amount of partial discharge was relatively small, and it gradually reduced even during the rapid growth of electrical trees, consequently, almost no partial discharges were found when the voltage was constant. Finally, a discharge-avalanche theory was proposed to explain the growth properties of DC electrical trees.
引用
收藏
页码:1965 / 1972
页数:8
相关论文
共 50 条
  • [21] MORPHOLOGY OF CROSS-LINKED POLYETHYLENE
    不详
    EPRI JOURNAL, 1983, 8 (08): : 47 - 47
  • [22] PHOTODEGRADATION OF CROSS-LINKED POLYETHYLENE
    TORIKAI, A
    ASADA, S
    FUEKI, K
    POLYMER PHOTOCHEMISTRY, 1986, 7 (01): : 1 - 11
  • [23] ON THE CRYSTALLIZATION OF CROSS-LINKED POLYETHYLENE
    BONGARDT, J
    MAY, M
    PLASTE UND KAUTSCHUK, 1986, 33 (05): : 172 - 175
  • [24] Charge distribution and electroluminescence in cross-linked polyethylene under dc field
    Teyssedre, G
    Laurent, C
    Montanari, GC
    Palmieri, F
    See, A
    Dissado, LA
    Fothergill, JC
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (18) : 2830 - 2844
  • [25] STABILIZATION OF CROSS-LINKED POLYETHYLENE
    STENGREVICS, E
    KING, RE
    HOFMANN, P
    POLYOLEFINS VI: SIXTH INTERNATIONAL CONFERENCE ON POLYOLEFINS, 1989, : 331 - 346
  • [26] STUDY OF INCEPTION AND GROWTH OF WATER TREES AND ELECTROCHEMICAL TREES IN POLYETHYLENE AND CROSS LINKED POLYETHYLENE INSULATIONS
    SLETBAK, J
    BOTNE, A
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1977, 12 (06): : 383 - 389
  • [27] Study on Pyrolysis Characteristics of Cross-linked Polyethylene Material Cable
    Mo Shan-jun
    Zhang Jun
    Liang Dong
    Chen Hong-yin
    2012 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING, 2013, 52 : 588 - 592
  • [28] Characteristics of Hyaluronic Acid Derivative Cross-linked by Polyethylene Glycol
    陈景华
    徐政
    Journal of Wuhan University of Technology-Materials Science, 2005, (S1) : 163 - 165
  • [29] Characteristics of hyaluronic acid derivative cross-linked by polyethylene glycol
    Chen, Jinghua
    Fan, Donghui
    Xu, Zheng
    Gu, Qisheng
    Journal Wuhan University of Technology, Materials Science Edition, 2005, 20 (SUPPL.): : 163 - 165
  • [30] Characteristics of highly cross-linked polyethylene wear debris in vivo
    Baxter, Ryan M.
    MacDonald, Daniel W.
    Kurtz, Steven M.
    Steinbeck, Marla J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (03) : 467 - 475