An electromagnetic calorimeter with a transversal orientation of the scintillating fibers

被引:0
|
作者
Bashmakov, YA
Gorbov, LA
Korbut, MS
Lebedev, AI
Lytkin, LK
Rusakov, SV
机构
[1] Russian Acad Sci, PN Lebedev Phys Inst, Moscow 119991, Russia
[2] Joint Inst Nucl Res, Dubna 141980, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Main Parameter; Energy Resolution; Measured Energy;
D O I
10.1023/A:1025117712358
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The space and energy resolutions of the SPACAL electromagnetic calorimeter with a transverse orientation of the scintillating fibers have been measured. The main parameters of the calorimeter are presented. The results of experiments with an electron test beam of the DESY synchrotron at energies E = 1-6 GeV are discussed. The measured energy resolution of the calorimeter is found to be (sigma/E) = 12.7%/ rootE + 2.0% (E is expressed in terms of GeV), and the space resolution is sigma(x,y)(E) = 1 mm at E = 4 GeV.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 50 条
  • [31] Studies on high energy γ trigger of lead-scintillating fiber electromagnetic calorimeter
    Yang, ZY
    Chen, GM
    Chen, G
    Yang, M
    Wang, XB
    Liu, ZH
    Zhang, SH
    Lü, YS
    Chen, HS
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (10): : 1086 - 1089
  • [32] Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter
    Akhmadaliev, S
    Albiol, F
    Amaral, P
    Ambrosini, G
    Amorim, A
    Anderson, K
    Andrieux, ML
    Aubert, B
    Augé, E
    Badaud, F
    Baisin, L
    Barreiro, F
    Battistoni, G
    Bazan, A
    Bazizi, K
    Bee, C
    Belorgey, J
    Belymam, A
    Benchekroun, D
    Berglund, S
    Berset, JC
    Blanchot, G
    Bogush, A
    Bohm, C
    Boldea, V
    Bonivento, W
    Borgeaud, P
    Borisov, O
    Bosman, M
    Bouhemaid, N
    Breton, D
    Brette, P
    Bromberg, C
    Budagov, J
    Burdin, S
    Caloba, L
    Camarena, F
    Camin, DV
    Canton, B
    Caprini, M
    Carvalho, J
    Casado, P
    Cases, R
    Castillo, MV
    Cavalli, D
    Cavalli-Sforza, M
    Cavasinni, V
    Chadelas, R
    Chalifour, M
    Chekhtman, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (03): : 461 - 477
  • [33] Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter
    Cobal, M
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 380 - 385
  • [34] Measurement of the neutron detection efficiency of a 80% absorber-20% scintillating fibers calorimeter
    Anelli, M.
    Bertolucci, S.
    Bini, C.
    Branchini, P.
    Corradi, G.
    Curceanu, C.
    De Zorzi, G.
    Di Domenico, A.
    Di Micco, B.
    Ferrari, A.
    Fiore, S.
    Gauzzi, P.
    Giovannella, S.
    Happacher, F.
    Iliescu, M.
    Luca, A.
    Martini, M.
    Miscetti, S.
    Nguyen, F.
    Passeri, A.
    Prokofiev, A. V.
    Sarra, I.
    Sciascia, B.
    Sirghi, F.
    Tagnani, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 626 : 67 - 71
  • [35] Performance of an electromagnetic lead/scintillating-fibre calorimeter for the H1 detector
    Nicholls, T
    Hajduk, L
    Janczur, W
    Rybicki, K
    Claxton, B
    Dowdell, J
    Deckers, H
    Deckers, T
    Dirkmann, M
    Hutte, M
    Hutter, M
    Kolanoski, H
    Poschl, R
    Schuhmacher, A
    Wacker, K
    Walther, A
    Wegener, D
    Wenk, T
    Cozzika, G
    Laforge, B
    Laporte, JF
    Perez, E
    Royon, C
    Villet, G
    Appuhn, RD
    Arndt, C
    Barschke, R
    Buchholz, R
    Georlach, U
    Korbel, V
    Lehner, F
    Meyer, A
    Muller, G
    Steiner, H
    Weber, M
    Ferencei, J
    Janoth, J
    Meier, K
    Schleif, S
    Stiewe, J
    Zuber, K
    Dau, WD
    Bruncko, D
    Krivan, F
    Maracek, R
    Murin, P
    Spalek, J
    Eisenhandler, E
    Landon, M
    Jonsson, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (02): : 149 - 156
  • [36] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    张诚
    李祖豪
    唐志成
    Suzan Basegmez du Pree
    张劭文
    王薛强
    杨民
    陈国明
    陈和生
    Chinese Physics C, 2016, 40 (09) : 137 - 141
  • [37] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    Zhang, Cheng
    Li, Zu-Hao
    Tang, Zhi-Cheng
    du Pree, Suzan Basegmez
    Zhang, Shao-Wen
    Wang, Xue-Qiang
    Yang, Min
    Chen, Guo-Ming
    Chen, He-Sheng
    CHINESE PHYSICS C, 2016, 40 (09)
  • [38] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    张诚
    李祖豪
    唐志成
    Suzan Basegmez du Pree
    张劭文
    王薛强
    杨民
    陈国明
    陈和生
    Chinese Physics C, 2016, (09) : 137 - 141
  • [39] SCINTILLATING FIBERS
    WHITE, TO
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 820 - 825
  • [40] SCINTILLATING FIBERS
    LEUTZ, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (03): : 422 - 448