An electromagnetic calorimeter with a transversal orientation of the scintillating fibers

被引:0
|
作者
Bashmakov, YA
Gorbov, LA
Korbut, MS
Lebedev, AI
Lytkin, LK
Rusakov, SV
机构
[1] Russian Acad Sci, PN Lebedev Phys Inst, Moscow 119991, Russia
[2] Joint Inst Nucl Res, Dubna 141980, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Main Parameter; Energy Resolution; Measured Energy;
D O I
10.1023/A:1025117712358
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The space and energy resolutions of the SPACAL electromagnetic calorimeter with a transverse orientation of the scintillating fibers have been measured. The main parameters of the calorimeter are presented. The results of experiments with an electron test beam of the DESY synchrotron at energies E = 1-6 GeV are discussed. The measured energy resolution of the calorimeter is found to be (sigma/E) = 12.7%/ rootE + 2.0% (E is expressed in terms of GeV), and the space resolution is sigma(x,y)(E) = 1 mm at E = 4 GeV.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 50 条
  • [21] Optimization of the structure of an electromagnetic calorimeter with longitudinal arrangement of absorbing and scintillating layers
    Korablev, AV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (01) : 6 - 8
  • [22] Study on angular resolution of lead-scintillating fiber electromagnetic calorimeter
    Wang, XB
    Chen, GM
    Li, ZH
    Chen, G
    Yang, M
    Yang, ZY
    Zhang, SH
    Lu, YS
    Chen, HS
    Li, XQ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (11): : 1071 - 1076
  • [23] The AMS-02 lead-scintillating fibres Electromagnetic Calorimeter
    Adloff, C.
    Basara, L.
    Bigongiari, G.
    Bosi, F.
    Brun, P.
    Cadoux, F.
    Cervelli, F.
    Chambert, V.
    Chen, G.
    Chen, G. M.
    Chen, H. S.
    Coignet, G.
    Cougoulat, G.
    Di Falco, S.
    Dubois, J. M.
    Elles, S.
    Falchini, E.
    Fiasson, A.
    Fougeron, D.
    Fouque, N.
    Galeotti, S.
    Gallucci, G.
    Gherarducci, F.
    Girard, L.
    Giuseppe, F.
    Goy, C.
    Hermel, R.
    Incagli, M.
    Jacquemier, J.
    Journet, L.
    Kossakowski, R.
    Lepareur, V.
    Li, Z. H.
    Lieunard, B.
    Lomtadze, T.
    Lu, Y. S.
    Maestro, P.
    Magazzu, C.
    Maire, M.
    Orsini, A.
    Paniccia, M.
    Pedreschi, E.
    Peltier, F.
    Piendibene, M.
    Pilo, F.
    Pochon, J.
    Rambure, T.
    Rosier-Lees, S.
    Spinella, F.
    Tang, X. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 714 : 147 - 154
  • [24] Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
    Li Zu-Hao
    Xu Wei-Wei
    Wang Ling-Yu
    Zhang Cheng
    Tang Zhi-Cheng
    Yan Qi
    Yang Min
    Lu Yu-Sheng
    Chen Guo-Ming
    Chen He-Sheng
    CHINESE PHYSICS C, 2014, 38 (05)
  • [25] Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
    李祖豪
    许伟伟
    王玲玉
    张诚
    唐志成
    严琪
    杨民
    吕雨生
    陈国明
    陈和生
    Chinese Physics C, 2014, 38 (05) : 78 - 83
  • [26] Optimization of the Structure of an Electromagnetic Calorimeter with Longitudinal Arrangement of Absorbing and Scintillating Layers
    A. V. Korablev
    Instruments and Experimental Techniques, 2002, 45 : 6 - 8
  • [27] SIMULATION STUDIES OF THE ELECTROMAGNETIC ENERGY RESOLUTION OF SCINTILLATING-FIBER CALORIMETER
    STAVINA, P
    TOKAR, S
    BUDAGOV, JA
    PANTEA, D
    DUKES, EC
    BAGDASAROV, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (01): : 124 - 132
  • [28] Results from a combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter
    Ajaltouni, Z
    Albiol, F
    Alifanov, A
    Amaral, P
    Ambrosini, G
    Amorim, A
    Anderson, K
    Astvatsaturov, A
    Aubert, B
    Auge, E
    Autiero, D
    Azuelos, G
    Badaud, F
    Baisin, L
    Battistoni, G
    Bazan, A
    Bee, C
    Bellettini, G
    Berglund, S
    Berset, JC
    Blaj, C
    Blanchot, G
    Blucher, E
    Bogush, A
    Bohm, C
    Boldea, V
    Borisov, O
    Bosman, M
    Bouhemaid, N
    Brette, P
    Bromberg, C
    Brossard, M
    Budagov, J
    Buono, S
    Caloba, L
    Camin, DV
    Canton, B
    Casado, P
    Cavalli, D
    CavalliSforza, M
    Cavasinni, V
    Chadelas, R
    Chase, R
    Chekhtman, A
    Chevaleyre, JC
    Chevalley, JL
    ChirikovZorin, I
    Chlachidze, G
    Chollet, JC
    Cobal, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 387 (03): : 333 - 351
  • [29] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    Li Zu-Hao
    Wang Ling-Yu
    Xu Wei-Wei
    Chen Guo-Ming
    Lu Yu-Sheng
    Chen He-Sheng
    CHINESE PHYSICS C, 2013, 37 (02)
  • [30] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    李祖豪
    王玲玉
    许伟伟
    陈国明
    吕雨生
    陈和生
    Chinese Physics C, 2013, 37 (02) : 68 - 71