An electromagnetic calorimeter with a transversal orientation of the scintillating fibers

被引:0
|
作者
Bashmakov, YA
Gorbov, LA
Korbut, MS
Lebedev, AI
Lytkin, LK
Rusakov, SV
机构
[1] Russian Acad Sci, PN Lebedev Phys Inst, Moscow 119991, Russia
[2] Joint Inst Nucl Res, Dubna 141980, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Main Parameter; Energy Resolution; Measured Energy;
D O I
10.1023/A:1025117712358
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The space and energy resolutions of the SPACAL electromagnetic calorimeter with a transverse orientation of the scintillating fibers have been measured. The main parameters of the calorimeter are presented. The results of experiments with an electron test beam of the DESY synchrotron at energies E = 1-6 GeV are discussed. The measured energy resolution of the calorimeter is found to be (sigma/E) = 12.7%/ rootE + 2.0% (E is expressed in terms of GeV), and the space resolution is sigma(x,y)(E) = 1 mm at E = 4 GeV.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 50 条
  • [1] An Electromagnetic Calorimeter with a Transversal Orientation of the Scintillating Fibers
    Yu. A. Bashmakov
    L. A. Gorbov
    M. S. Korbut
    A. I. Lebedev
    L. K. Lytkin
    S. V. Rusakov
    Instruments and Experimental Techniques, 2003, 46 : 462 - 466
  • [2] PERFORMANCE OF A SCINTILLATING FIBERS SEMIPROJECTIVE ELECTROMAGNETIC CALORIMETER
    BERTINO, M
    BINI, C
    DEZORZI, G
    PALAZZI, GD
    DICOSIMO, G
    DIDOMENICO, A
    GARUFI, F
    GAUZZI, P
    ZANELLO, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (2-3): : 363 - 368
  • [3] PERFORMANCE OF A HIGHLY SEGMENTED SCINTILLATING FIBERS ELECTROMAGNETIC CALORIMETER
    ASMONE, A
    BERTINO, M
    BINI, C
    DEZORZI, G
    PALAZZI, GD
    DICOSIMO, G
    DIDOMENICO, A
    GARUFI, F
    GAUZZI, P
    ZANELLO, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (03): : 477 - 482
  • [4] TEST-RESULTS OF AN ELECTROMAGNETIC CALORIMETER WITH 0.5 MM SCINTILLATING FIBERS READOUT
    BADIER, J
    BOUHEMAID, N
    BUONTEMPO, S
    BUSSON, P
    CALOBA, L
    CATTANEO, P
    CHARLOT, C
    CHEKHTMAN, A
    COUSINOU, MC
    DAGORET, S
    DELLACQUA, A
    EREDITATO, A
    FERRARI, R
    FOUCHEZ, D
    FREDJ, L
    FUMAGALLI, G
    GAILLARD, JM
    GOGGI, G
    GOMES, A
    HANSLKOZANECKA, T
    HENRIQUES, A
    KOVACS, F
    LINSSEN, L
    LIVAN, M
    LORY, J
    MAIO, A
    MICHEL, B
    MONTAROU, G
    NACASCH, R
    NAGY, E
    PAAR, HP
    PALLIN, D
    PENNACCHIO, E
    PERALTA, L
    POGGIOLI, L
    POLESELLO, G
    RICCARDI, F
    RIMOLDI, A
    SEIXAS, JM
    SIVERTZ, M
    SOUZA, MN
    THOME, ZD
    TISSERANT, S
    TOME, B
    VAZEILLE, F
    VERCESI, V
    WIGMANS, R
    ZITOUN, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 314 - 325
  • [5] Scintillating LXe/LKr electromagnetic calorimeter
    Akimov, DY
    Bolozdynya, AJ
    Churakov, DL
    Afonasyev, VN
    Belogurov, SG
    Brastilov, AD
    Burenkov, AA
    Gusev, LN
    Kuzichev, VF
    Lebedenko, VN
    Osipova, TA
    Rogovsky, IA
    Safronov, GA
    Simonychev, A
    Solovov, VN
    Sopov, VS
    Smirnov, GN
    Tchernyshev, VP
    Chen, M
    Smolin, MM
    Turchinetz, W
    Minakova, RA
    Shershukov, VM
    Dodohov, VH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) : 2244 - 2249
  • [6] PERFORMANCE OF A SCINTILLATING GLASS CALORIMETER FOR ELECTROMAGNETIC SHOWERS
    BUCHNER, U
    DONKER, JP
    SPAAN, B
    SPENGLER, J
    SCHWEDA, G
    WEGENER, D
    SCHMIDTPARZEFALL, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (03): : 695 - 706
  • [7] Performance of a scintillating glass calorimeter for electromagnetic showers
    Buchner, U.
    Donker, J.P.
    Spaan, B.
    Spengler, J.
    Schweda, G.
    Wegener, D.
    Schmidt-Parzefall, W.
    Nuclear instruments and methods in physics research, 1988, 272 (03): : 695 - 706
  • [8] Performance of a scintillating fibres semiprojective electromagnetic calorimeter
    Bertino, M
    Bini, C
    DeZorzi, G
    Palazzi, GD
    DiCosimo, G
    DiDomenico, A
    Garufi, F
    Gauzzi, P
    Zanello, D
    NUCLEAR PHYSICS B, 1995, : 163 - 167
  • [9] AN ELECTROMAGNETIC CALORIMETER PROTOTYPE MODULE USING SCINTILLATING FIBERS IMMERSED IN A BI-PB ALLOY
    BLUMENFELD, H
    BOURDINAUD, M
    BURMEISTER, H
    CESTER, R
    CHECCHIA, P
    ZUMERLE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03): : 518 - 521
  • [10] Dual readout calorimeter with heavy scintillating crystal fibers
    Auffray, E.
    Abler, D.
    Lecoq, P.
    Dujardin, C.
    Fourmigue, J. M.
    Perrodin, D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2537 - +