Analytical method validation for terbutryn using gas chromatography/ion trap, gas chromatography/mass selective detector, and liquid chromatography/triple quadrupole mass spectrometers

被引:1
|
作者
Jang, Hae Won [1 ]
Lee, Jangho [1 ,3 ]
Choi, Hyunwook [1 ]
Nam, Tae Gyu [1 ]
Kim, Seung-Hyun [2 ]
Lee, Kwang-Geun [4 ]
机构
[1] Korea Food Res Inst, Seongnam 13539, Gyeonggi, South Korea
[2] Konkuk Univ, Dept Appl Biosci, Coll Life & Environm Sci, Seoul 05029, South Korea
[3] Korea Univ Sci & Technol, Food Biotechnol Program, Daejeon 34113, South Korea
[4] Dongguk Univ, Dept Food Sci & Biotechnol, 32 Dongguk Ro, Goyang 10326, Gyeonggi Do, South Korea
关键词
Terbutryn; Gas chromatography/mass selective detector; Gas chromatography/ion trap; Liquid chromatography/triple quadrupole mass spectrometers; SOLID-PHASE EXTRACTION; TRIAZINE HERBICIDES; MICROEXTRACTION FIBER; IN-VITRO; PESTICIDES; WATER; SURFACE; GROUNDWATER; POLLUTION; ATRAZINE;
D O I
10.1007/s10068-018-0355-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Analytical methods including solvent extraction followed by gas chromatography/ion-trap (GC/IT) with scan and MS/MS mode, a GC/mass selective detector (GC/MSD), and liquid chromatography/triple quadrupole mass spectrometers (LC/MS/MS) were optimized to identify and quantify terbutryn. The spike recovery was 96.5% using GC/IT with scan mode and 103.5% with MS/MS mode, 90.3% by GC/MSD, and 92.5% by LC/MS/MS. The limit of detection (LOD) was 0.0015mg/kg by GC/IT with scan, 0.026mg/kg with MS/MS mode, 0.015mg/kg with GC/MSD, and 0.026mg/kg by LC/MS/MS. Of the four methods, GC/IT with scan mode was determined to be the most sensitive (with LOD: 0.0015mg/kg and limit of quantitation (LOQ): 0.0047mg/kg), rapid (retention time: 9.6min) and the most precise method (relative standard deviation: 17%) for the quantification of terbutryn. GC/IT with scan mode proved to be the more sensitive analytical method for terbutryn than other methods in this study, showing better accuracy and rapid analysis.
引用
收藏
页码:1525 / 1530
页数:6
相关论文
共 50 条
  • [31] Methenamine in dairy products by isotope dilution gas chromatography coupled with triple quadrupole mass spectrometry: Method validation and occurrence
    Xu, Xing
    Zhang, Xiaoming
    Abbas, Shabbar
    Karangwa, Eric
    Duhoranimana, Emmanuel
    Peng, Feijin
    Shu, Ping
    FOOD CONTROL, 2015, 57 : 89 - 95
  • [32] Determination of dioxins/furans and PCBs by quadrupole ion-trap gas chromatography-mass spectrometry
    Plomley, JB
    Lausevic, M
    March, RE
    MASS SPECTROMETRY REVIEWS, 2000, 19 (05) : 305 - 365
  • [33] USE OF MASS-SPECTROMETER AS A SELECTIVE GAS-CHROMATOGRAPHY DETECTOR
    LEIBRAND, RJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1976, 172 (SEP3): : 110 - 110
  • [34] DISOPYRAMIDE DETERMINATION BY GAS-CHROMATOGRAPHY, LIQUID-CHROMATOGRAPHY, AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    VASILIADES, J
    OWENS, C
    RAGUSA, F
    CLINICAL CHEMISTRY, 1979, 25 (11) : 1900 - 1904
  • [35] Analytical Method Validation for Determining Organophosphorus Pesticides in Baby Foods by a Modified Liquid-Liquid Microextraction Method and Gas Chromatography-Ion Trap/Mass Spectrometry Analysis
    Notardonato, Ivan
    Russo, Mario Vincenzo
    Vitali, Matteo
    Protano, Carmela
    Avino, Pasquale
    FOOD ANALYTICAL METHODS, 2019, 12 (01) : 41 - 50
  • [36] Development and application of an analytical method using gas chromatography/triple quadrupole mass spectrometry for characterizing alkylated chrysenes in crude oil samples
    John, G. F.
    Yin, F.
    Mulabagal, V.
    Hayworth, J. S.
    Clement, T. P.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (08) : 948 - 956
  • [37] Analytical method using gas chromatography and ion trap tandem mass spectrometry for the determination of S-triazines and their metabolites in the atmosphere
    Sauret, N
    Millet, M
    Herckes, P
    Mirabel, P
    Wortham, H
    ENVIRONMENTAL POLLUTION, 2000, 110 (02) : 243 - 252
  • [38] Methanol Detection in Transformer Oils using Gas Chromatography and Ion Trap Mass Spectrometer
    Matharage, S. Y.
    Liu, Q.
    Davenport, E.
    Wilson, G.
    Walker, D.
    Wang, Z. D.
    PROCEEDINGS OF THE 2014 IEEE 18TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL 2014), 2014,
  • [39] Characterization of powdered turmeric by liquid chromatography mass spectrometry and gas chromatography mass spectrometry
    Hiserodt, R
    Hartman, TG
    Ho, CT
    Rosen, RT
    JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (01) : 51 - 63
  • [40] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    KAISER, RE
    WILLIAMS, JD
    LAMMERT, SA
    COOKS, RG
    ZAKETT, D
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 562 (1-2): : 3 - 11