Analytical method validation for terbutryn using gas chromatography/ion trap, gas chromatography/mass selective detector, and liquid chromatography/triple quadrupole mass spectrometers

被引:1
|
作者
Jang, Hae Won [1 ]
Lee, Jangho [1 ,3 ]
Choi, Hyunwook [1 ]
Nam, Tae Gyu [1 ]
Kim, Seung-Hyun [2 ]
Lee, Kwang-Geun [4 ]
机构
[1] Korea Food Res Inst, Seongnam 13539, Gyeonggi, South Korea
[2] Konkuk Univ, Dept Appl Biosci, Coll Life & Environm Sci, Seoul 05029, South Korea
[3] Korea Univ Sci & Technol, Food Biotechnol Program, Daejeon 34113, South Korea
[4] Dongguk Univ, Dept Food Sci & Biotechnol, 32 Dongguk Ro, Goyang 10326, Gyeonggi Do, South Korea
关键词
Terbutryn; Gas chromatography/mass selective detector; Gas chromatography/ion trap; Liquid chromatography/triple quadrupole mass spectrometers; SOLID-PHASE EXTRACTION; TRIAZINE HERBICIDES; MICROEXTRACTION FIBER; IN-VITRO; PESTICIDES; WATER; SURFACE; GROUNDWATER; POLLUTION; ATRAZINE;
D O I
10.1007/s10068-018-0355-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Analytical methods including solvent extraction followed by gas chromatography/ion-trap (GC/IT) with scan and MS/MS mode, a GC/mass selective detector (GC/MSD), and liquid chromatography/triple quadrupole mass spectrometers (LC/MS/MS) were optimized to identify and quantify terbutryn. The spike recovery was 96.5% using GC/IT with scan mode and 103.5% with MS/MS mode, 90.3% by GC/MSD, and 92.5% by LC/MS/MS. The limit of detection (LOD) was 0.0015mg/kg by GC/IT with scan, 0.026mg/kg with MS/MS mode, 0.015mg/kg with GC/MSD, and 0.026mg/kg by LC/MS/MS. Of the four methods, GC/IT with scan mode was determined to be the most sensitive (with LOD: 0.0015mg/kg and limit of quantitation (LOQ): 0.0047mg/kg), rapid (retention time: 9.6min) and the most precise method (relative standard deviation: 17%) for the quantification of terbutryn. GC/IT with scan mode proved to be the more sensitive analytical method for terbutryn than other methods in this study, showing better accuracy and rapid analysis.
引用
收藏
页码:1525 / 1530
页数:6
相关论文
共 50 条
  • [21] HD gas analysis with gas chromatography and quadrupole mass spectrometer
    Ohta, T.
    Bouchigny, S.
    Didelez, J. -P.
    Fujiwara, M.
    Fukuda, K.
    Kohri, H.
    Kunimatsu, T.
    Morisaki, C.
    Ono, S.
    Rouille, G.
    Tanaka, M.
    Ueda, K.
    Uraki, M.
    Utsuro, M.
    Wang, S. Y.
    Yosoi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 640 (01): : 241 - 246
  • [22] Detection and Characterization of Fumonisin Mycotoxins by Liquid Chromatography/Electrospray Ionization Using Ion Trap and Triple Quadrupole Mass Spectrometry
    Josephs, J. L.
    Rapid Communications in Mass Spectrometry, 10 (11):
  • [24] Miniaturized GUMS instrumentation for in situ measurements:: micro gas chromatography coupled with miniature quadrupole array and Paul ion trap mass spectrometers
    Holland, PM
    Chutjian, A
    Darrach, MR
    Orient, OJ
    FIRST JET PROPULSION LABORATORY IN SITU INSTRUMENTS WORKSHOP, 2003, 4878 : 1 - 7
  • [25] SIMPLE, DIRECT GAS-CHROMATOGRAPHY MASS-SPECTROMETRY INTERFACE FOR THE ION TRAP DETECTOR
    STOUT, SJ
    DACUNHA, AR
    JOURNAL OF CHROMATOGRAPHY, 1990, 504 (02): : 429 - 433
  • [26] Difference of quantity analysis with quadrupole mass detector and flame ionization detector in gas chromatography
    Fan, Guo-Liang
    Song, Chong-Lin
    Zhang, Yan-Feng
    Zhou, Wei-Yi
    Yan, Ying
    Wang, Jing
    Jiang, Dong-Feng
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2003, 36 (05): : 614 - 617
  • [27] ABSOLUTE MASS INTEGRAL DETECTOR FOR GAS CHROMATOGRAPHY
    BEVAN, SC
    THORBURN, S
    CHEMISTRY IN BRITAIN, 1965, 1 (05) : 206 - &
  • [28] Innovative analytical method for the determination of underivatized tributyltin and pentachlorophenol in seawater by gas chromatography-triple quadrupole mass spectrometry
    Amendola, Luca
    Cortese, Maria
    Vinatoru, Daniela
    Sposato, Silvana
    Insogna, Susanna
    ANALYTICA CHIMICA ACTA, 2017, 975 : 70 - 77
  • [29] Gas Chromatography-Triple Quadrupole Mass Spectrometry Analysis of Dioxins in Soil
    Kwon, Young Sang
    Choi, Sung-Gil
    Lee, Seung-Min
    Kim, Jong-Hwan
    Seo, Jong-Su
    ACTA CHROMATOGRAPHICA, 2019, 31 (03) : 235 - 240
  • [30] Application of isotope dilution to ion trap gas chromatography mass spectrometry
    Barshick, CM
    Barshick, SA
    Walsh, EB
    Vance, MA
    Britt, PF
    ANALYTICAL CHEMISTRY, 1999, 71 (02) : 483 - 488