Analytical method validation for terbutryn using gas chromatography/ion trap, gas chromatography/mass selective detector, and liquid chromatography/triple quadrupole mass spectrometers

被引:1
|
作者
Jang, Hae Won [1 ]
Lee, Jangho [1 ,3 ]
Choi, Hyunwook [1 ]
Nam, Tae Gyu [1 ]
Kim, Seung-Hyun [2 ]
Lee, Kwang-Geun [4 ]
机构
[1] Korea Food Res Inst, Seongnam 13539, Gyeonggi, South Korea
[2] Konkuk Univ, Dept Appl Biosci, Coll Life & Environm Sci, Seoul 05029, South Korea
[3] Korea Univ Sci & Technol, Food Biotechnol Program, Daejeon 34113, South Korea
[4] Dongguk Univ, Dept Food Sci & Biotechnol, 32 Dongguk Ro, Goyang 10326, Gyeonggi Do, South Korea
关键词
Terbutryn; Gas chromatography/mass selective detector; Gas chromatography/ion trap; Liquid chromatography/triple quadrupole mass spectrometers; SOLID-PHASE EXTRACTION; TRIAZINE HERBICIDES; MICROEXTRACTION FIBER; IN-VITRO; PESTICIDES; WATER; SURFACE; GROUNDWATER; POLLUTION; ATRAZINE;
D O I
10.1007/s10068-018-0355-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Analytical methods including solvent extraction followed by gas chromatography/ion-trap (GC/IT) with scan and MS/MS mode, a GC/mass selective detector (GC/MSD), and liquid chromatography/triple quadrupole mass spectrometers (LC/MS/MS) were optimized to identify and quantify terbutryn. The spike recovery was 96.5% using GC/IT with scan mode and 103.5% with MS/MS mode, 90.3% by GC/MSD, and 92.5% by LC/MS/MS. The limit of detection (LOD) was 0.0015mg/kg by GC/IT with scan, 0.026mg/kg with MS/MS mode, 0.015mg/kg with GC/MSD, and 0.026mg/kg by LC/MS/MS. Of the four methods, GC/IT with scan mode was determined to be the most sensitive (with LOD: 0.0015mg/kg and limit of quantitation (LOQ): 0.0047mg/kg), rapid (retention time: 9.6min) and the most precise method (relative standard deviation: 17%) for the quantification of terbutryn. GC/IT with scan mode proved to be the more sensitive analytical method for terbutryn than other methods in this study, showing better accuracy and rapid analysis.
引用
收藏
页码:1525 / 1530
页数:6
相关论文
共 50 条
  • [1] Analytical method validation for terbutryn using gas chromatography/ion trap, gas chromatography/mass selective detector, and liquid chromatography/triple quadrupole mass spectrometers
    Hae Won Jang
    Jangho Lee
    Hyunwook Choi
    Tae Gyu Nam
    Seung-Hyun Kim
    Kwang-Geun Lee
    Food Science and Biotechnology, 2018, 27 : 1525 - 1530
  • [2] Development and Comparison of Analytical Methods for Measuring Simazine Herbicide Using Gas Chromatography/Ion Trap, Gas Chromatography/Mass Selective Detector, and High Performance Liquid Chromatography/Triple Quadrupole Mass Spectrometers
    Chung, Ill-Min
    Park, Inmyoung
    Kim, Seung-Hyun
    JOURNAL OF THE KOREAN SOCIETY FOR APPLIED BIOLOGICAL CHEMISTRY, 2011, 54 (05): : 744 - 749
  • [3] Development and comparison of analytical methods for measuring simazine herbicide using gas chromatography/ion trap, gas chromatography/mass selective detector, and high performance liquid chromatography/triple quadrupole mass spectrometers
    Ill-Min Chung
    Inmyoung Park
    Seung-Hyun Kim
    Journal of the Korean Society for Applied Biological Chemistry, 2011, 54 (5): : 744 - 749
  • [4] Analysis of Pesticides Residues in Fresh Produce Using Buffered Acetonitrile Extraction and Aminopropyl Cleanup with Gas Chromatography/Triple Quadrupole Mass Spectrometry, Liquid Chromatography/Triple Quadrupole Mass Spectrometry, Gas Chromatography/Ion Trap Detector Mass Spectrometry, and GC with a Halogen-Specific Detector
    Brown, Amy N.
    Cook, Jo Marie
    Hammack, Walter T.
    Stepp, Jason S.
    Pelt, Jonathan V.
    Gerard, Ghislain
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (03) : 931 - 941
  • [5] Determination of polychlorodibenzo-p-dioxins and polychlorodibenzofurans by gas chromatography/tandem mass spectrometry and gas chromatography/triple mass spectrometry in a quadrupole ion trap
    Helen, C
    Lemasle, M
    Laplanche, A
    Genin, E
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (05): : 546 - 554
  • [6] High performance liquid chromatography quadrupole ion trap and gas chromatography mass spectrometry studies of polyhydroxyalkaloids in bluebells
    Egan, MJ
    Porter, EA
    Kite, GC
    Simmonds, MSJ
    Barker, J
    Howells, S
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (04) : 195 - 200
  • [7] Comparison of liquid chromatography using triple quadrupole and quadrupole ion trap mass analyzers to determine pesticide residues in oranges
    Soler, C
    Mañes, J
    Picó, Y
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1067 (1-2) : 115 - 125
  • [8] Validation of a gas chromatography/triple quadrupole mass spectrometry based method for the quantification of pesticides in food commodities
    Vidal, JLM
    Liébanas, FJA
    Rodríguez, MJG
    Frenich, AG
    Moreno, JLF
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (03) : 365 - 375
  • [9] Use of a liquid chromatography/ion trap mass spectrometry/triple quadrupole mass spectrometry system for metabolite identification
    Liu, DQ
    Xia, YQ
    Bakhtiar, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (13) : 1330 - 1336
  • [10] Development and Validation of Analytical Method Using Gas Chromatography with Triple Quadrupole Mass Spectrometry for the Detection of Alkyl Halides as Potential Genotoxic Impurities in Posaconazole
    Chittireddy, Hari Naga Prasada Reddy
    Kumar, J. V. Shanmukha
    Bhimireddy, Anuradha
    Shaik, Mohammed Rafi
    Khan, Mujeeb
    Khan, Merajuddin
    Oh, Tae Hwan
    Shaik, Baji
    SEPARATIONS, 2023, 10 (05)