Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy

被引:1
|
作者
Edwick, Dale O. [1 ,2 ,3 ]
Hince, Dana A. [4 ]
Rawlins, Jeremy M. [1 ,5 ]
Wood, Fiona M. [1 ,3 ,6 ]
Edgar, Dale W. [1 ,3 ,4 ]
机构
[1] Fiona Stanley Hosp, State Adult Burns Unit, CD15,102-118 Murdoch Dr, Murdoch, WA 6150, Australia
[2] Univ Notre Dame Australia, Sch Physiotherapy, Fremantle, WA, Australia
[3] Fiona Stanley Hosp, Fiona Wood Fdn, Murdoch, WA, Australia
[4] Univ Notre Dame Australia, Inst Hlth Res, Fremantle, WA, Australia
[5] Royal Perth Hosp, Dept Plast & Maxillofacial Surg, Perth, WA, Australia
[6] Univ Western Australia, Burn Injury Res Unit, Nedlands, WA, Australia
关键词
bioelectrical impedance analysis; electrode sites; body composition; body fluid distribution; wounds; hand volume; BIOELECTRICAL-IMPEDANCE ANALYSIS; CONCURRENT VALIDITY; EDEMA; LYMPHEDEMA; WATER; BODY; RELIABILITY; FREQUENCY; AGREEMENT; SITES;
D O I
10.1089/lrb.2019.0078
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Bioimpedance spectroscopy (BIS) is a tool that can be used to measure body composition in a variety of populations. Previous studies have investigated novel applications to utilize BIS to measure localized body composition, including in the hand. According to BIS guidelines, there should be no skin wounds at the site of electrodes, and that electrode positions may be modified in specific circumstances, as our group has validated previously in burn wound populations. Methods and Results: To determine in noninjured participants, whether BIS measurements recorded using alternate electrode positions on the palm of the hand and forearm, or a combination of electrodes on the dorsum and volar surface of the hand and forearm, were comparable with electrode positions on the dorsum of the hand and forearm. The study demonstrated that drive and sense electrodes on the palm of the hand and volar forearm, and a combination of electrodes on the palm of the hand and dorsum of the forearm, resulted in comparable measures of impedance of extracellular water (difference from reference position: 1.26%-4.75%, p = 0.411-0.558) and total water (difference from reference: 2.15%-2.40%, p = 0.258-0.781). Electrodes on the dorsum of the hand and volar forearm resulted in significantly different measures for the same BIS variables (percentage difference range 4.66%-6.15%, p < 0.001-0.003). Conclusion: Electrode positions on the palm of the hand and volar forearm, or on the palm of the hand and dorsum of the forearm, are interchangeable as clinical measures of hand lymphedema and total water impedance.
引用
收藏
页码:560 / 571
页数:12
相关论文
共 50 条
  • [41] Electrode errors in bioimpedance measurement systems for long-term applications
    Lozano, A
    PROCEEDINGS OF THE 1997 16TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1997, : 3 - 6
  • [42] Electrode Placement Strategies for the Measurement of Radial Artery Bioimpedance: Simulations and Experiments
    Pesti, K.
    Metshein, M.
    Annus, P.
    Koiv, H.
    Min, M.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [43] Pulse Transit Time Measurement Using Bioimpedance
    Pires, Andrei L. A.
    Souza, Marcio N.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL 1, 2019, 70 (01): : 531 - 535
  • [44] Design and Implementation of a Hand-To-Hand Multifrequency Bioimpedance Measurement Scheme for Total Body Water Estimation
    Anusha, A. S.
    Preejith, S. P.
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 329 - 334
  • [45] RELIABILITY OF ULTRASOUND MEASUREMENT OF BLADDER VOLUMES IN SEATED VS SUPINE POSITIONS
    MASSAGLI, TL
    CARDENAS, DD
    KELLY, E
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1988, 69 (09): : 747 - 747
  • [46] A Practical Method to Reduce Electrode Mismatch Artefacts during 4-electrode BioImpedance Spectroscopy Measurements
    Montalibet, A.
    McAdams, E.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5775 - 5779
  • [47] Validity of hand-to-foot measurement of bioimpedance: Standing compared with lying position
    Rush, Elaine C.
    Crowley, Jennifer
    Freitas, Ismael F.
    Luke, Amy
    OBESITY, 2006, 14 (02) : 252 - 257
  • [48] Nanocrystalline silver dressings significantly influence bioimpedance spectroscopy measurements of fluid volumes in burns patients
    Grisbrook, Tiffany L.
    Kenworthy, Pippa
    Phillips, Michael
    Wood, Fiona M.
    Edgar, Dale W.
    BURNS, 2016, 42 (07) : 1548 - 1555
  • [49] Bioimpedance Spectroscopy Measurement and Classification of Lung Tissue to Identify Pulmonary Nodules
    Baghbani, Rasool
    Shadmehr, Mohammad Behgam
    Ashoorirad, Masoomeh
    Molaeezadeh, Seyyedeh Fatemeh
    Moradi, Mohammad Hassan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [50] Hydration measurement by bioimpedance spectroscopy and blood pressure management in children on hemodialysis
    Ariane Zaloszyc
    Betti Schaefer
    Franz Schaefer
    Saoussen Krid
    Rémi Salomon
    Patrick Niaudet
    Claus Peter Schmitt
    Michel Fischbach
    Pediatric Nephrology, 2013, 28 : 2169 - 2177