Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy

被引:1
|
作者
Edwick, Dale O. [1 ,2 ,3 ]
Hince, Dana A. [4 ]
Rawlins, Jeremy M. [1 ,5 ]
Wood, Fiona M. [1 ,3 ,6 ]
Edgar, Dale W. [1 ,3 ,4 ]
机构
[1] Fiona Stanley Hosp, State Adult Burns Unit, CD15,102-118 Murdoch Dr, Murdoch, WA 6150, Australia
[2] Univ Notre Dame Australia, Sch Physiotherapy, Fremantle, WA, Australia
[3] Fiona Stanley Hosp, Fiona Wood Fdn, Murdoch, WA, Australia
[4] Univ Notre Dame Australia, Inst Hlth Res, Fremantle, WA, Australia
[5] Royal Perth Hosp, Dept Plast & Maxillofacial Surg, Perth, WA, Australia
[6] Univ Western Australia, Burn Injury Res Unit, Nedlands, WA, Australia
关键词
bioelectrical impedance analysis; electrode sites; body composition; body fluid distribution; wounds; hand volume; BIOELECTRICAL-IMPEDANCE ANALYSIS; CONCURRENT VALIDITY; EDEMA; LYMPHEDEMA; WATER; BODY; RELIABILITY; FREQUENCY; AGREEMENT; SITES;
D O I
10.1089/lrb.2019.0078
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Bioimpedance spectroscopy (BIS) is a tool that can be used to measure body composition in a variety of populations. Previous studies have investigated novel applications to utilize BIS to measure localized body composition, including in the hand. According to BIS guidelines, there should be no skin wounds at the site of electrodes, and that electrode positions may be modified in specific circumstances, as our group has validated previously in burn wound populations. Methods and Results: To determine in noninjured participants, whether BIS measurements recorded using alternate electrode positions on the palm of the hand and forearm, or a combination of electrodes on the dorsum and volar surface of the hand and forearm, were comparable with electrode positions on the dorsum of the hand and forearm. The study demonstrated that drive and sense electrodes on the palm of the hand and volar forearm, and a combination of electrodes on the palm of the hand and dorsum of the forearm, resulted in comparable measures of impedance of extracellular water (difference from reference position: 1.26%-4.75%, p = 0.411-0.558) and total water (difference from reference: 2.15%-2.40%, p = 0.258-0.781). Electrodes on the dorsum of the hand and volar forearm resulted in significantly different measures for the same BIS variables (percentage difference range 4.66%-6.15%, p < 0.001-0.003). Conclusion: Electrode positions on the palm of the hand and volar forearm, or on the palm of the hand and dorsum of the forearm, are interchangeable as clinical measures of hand lymphedema and total water impedance.
引用
收藏
页码:560 / 571
页数:12
相关论文
共 50 条
  • [31] Lung Volumes and Ventilation Assessment Using Multifrequency Bioimpedance Meter
    Leonov, Vladimir
    Ha, Huynsoo
    SENSORS AND ELECTRONIC INSTRUMENTATION ADVANCES (SEIA' 19), 2019, : 282 - 285
  • [32] Exploration and Validation of Alternate Sensing Methods for Wearable Continuous Pulse Transit Time Measurement Using Optical and Bioimpedance Modalities
    Ibrahim, Bassem
    Nathan, Viswam
    Jafari, Roozbeh
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2051 - 2055
  • [33] Total body water measurement by a modification of the bioimpedance spectroscopy method
    Jaffrin, Michel Y.
    Fenech, Marianne
    Moreno, Marie Valerie
    Kieffer, Roland
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (10) : 873 - 882
  • [34] Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
    Sharon A. Czerniec
    Leigh C. Ward
    Mi-Joung Lee
    Kathryn M. Refshauge
    Jane Beith
    Sharon L. Kilbreath
    Supportive Care in Cancer, 2011, 19 : 703 - 710
  • [35] Design and preliminary evaluation of a portable device for the measurement of bioimpedance spectroscopy
    Yang, Yuxiang
    Wang, Jue
    Yu, Gang
    Niu, Feilong
    He, Ping
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (12) : 1293 - 1310
  • [36] Total body water measurement by a modification of the bioimpedance spectroscopy method
    Michel Y. Jaffrin
    Marianne Fenech
    Marie Valèrie Moreno
    Roland Kieffer
    Medical and Biological Engineering and Computing, 2006, 44 : 873 - 882
  • [37] Segmental measurement of breast cancer-related arm lymphoedema using perometry and bioimpedance spectroscopy
    Czerniec, Sharon A.
    Ward, Leigh C.
    Lee, Mi-Joung
    Refshauge, Kathryn M.
    Beith, Jane
    Kilbreath, Sharon L.
    SUPPORTIVE CARE IN CANCER, 2011, 19 (05) : 703 - 710
  • [38] Comparative Study of Measurement Methods for Embedded Bioimpedance Spectroscopy Systems
    Ben Atitallah, Bilel
    Kallel, Ahmed Yahia
    Bouchaala, Dhouha
    Derbel, Nabil
    Kanoun, Olfa
    SENSORS, 2022, 22 (15)
  • [39] ESTIMATION OF BODY FLUID VOLUMES BY BIOIMPEDANCE SPECTROSCOPY IN PATIENTS WITH HYPONATREMIACAN REPLACE PHYSICAL EXAM
    Kim, Jae Seok
    Han, Byoung Geun
    Choi, Seung Ok
    Yang, Jae Won
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 370 - 371
  • [40] Evaluation of Bioimpedance Spectroscopy (BIS) for Determination of Body Fluid Compartment Volumes (BFC) in Rats
    Hu, Lufei
    Maslanik, Thomas
    Zerebeckyj, Mykolai
    Plato, Craig F.
    FASEB JOURNAL, 2010, 24