COMPARISON OF PROSTATE IMRT AND VMAT BIOLOGICALLY OPTIMISED TREATMENT PLANS

被引:60
|
作者
Hardcastle, Nicholas [1 ]
Tome, Wolfgang A.
Foo, Kerwyn
Miller, Andrew
Carolan, Martin
Metcalfe, Peter
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol & Med Phys, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
VMAT; IMRT; Prostate; Biological Optimisation; SINGLE-ARC IMRT; VOLUMETRIC MODULATED ARC; BIOL-PHYS; 2008/70996-1001; CONFORMAL RADIOTHERAPY; COMPLICATION PROBABILITY; RADIATION-THERAPY; CANCER; DELIVERY; MODELS; TRIAL;
D O I
10.1016/j.meddos.2010.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Recently, a new radiotherapy delivery technique has become clinically available-volumetric modulated arc therapy (VMAT). VMAT is the delivery of IMRT while the gantry is in motion using dynamic leaf motion. The perceived benefit of VMAT over IMRT is a reduction in delivery time. In this study, VMAT was compared directly with IMRT for a series of prostate cases. For 10 patients, a biologically optimized seven-field IMRT plan was compared with a biologically optimized VMAT plan using the same planning objectives. The Pinnacle RTPS was used. The resultant target and organ-at-risk dose-volume histograms (DVHs) were compared. The normal tissue complication probability (NTCP) for the IMRT and VMAT plans was calculated for 3 model parameter sets. The delivery efficiency and time for the IMRT and VMAT plans was compared. The VMAT plans resulted in a statistically significant reduction in the rectal V25Gy parameter of 8.2% on average over the DIRT plans. For one of the NTCP parameter sets, the VMAT plans had a statistically significant lower rectal NTCP. These reductions in rectal dose were achieved using 18.6% fewer monitor units and a delivery time reduction of up to 69%. VMAT plans resulted in reductions in rectal doses for all 10 patients in the study. This was achieved with significant reductions in delivery time and monitor units. Given the target coverage was equivalent, the VMAT plans were superior. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 50 条
  • [41] Retrospective dosimetric evaluation of VMAT plans for prostate cancer treatment
    Darko, Johnson
    Osei, Ernest
    Fleck, Andre
    Rachakonda, Ramana
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 155 - 164
  • [42] Comparison of Coplanar VMAT, Non-Coplanar VMAT, and elk Treatment Plans
    Woods, K.
    Nguyen, D.
    Tran, A.
    Yu, V.
    Cao, M.
    Sheng, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3530 - 3530
  • [43] Optimised robust treatment plans for prostate cancer focal brachytherapy
    Betts, John M.
    Mears, Christopher
    Reynolds, Hayley M.
    Tack, Guido
    Leo, Kevin
    Ebert, Martin A.
    Haworth, Annette
    INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE, ICCS 2015 COMPUTATIONAL SCIENCE AT THE GATES OF NATURE, 2015, 51 : 914 - 923
  • [44] Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans
    Kawashima M.
    Ozawa S.
    Haga A.
    Sakumi A.
    Kurokawa C.
    Sugimoto S.
    Karasawa K.
    Nakagawa K.
    Sasai K.
    Radiological Physics and Technology, 2013, 6 (1) : 14 - 20
  • [45] Margin-less prostate IMRT plans, directly optimised for TCP including geometrical uncertainties
    Witte, M
    van der Geer, J
    Schneider, C
    Lebesque, J
    Alber, M
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S101 - S102
  • [46] Comparison of Treatment Planning and Delivery Performance of VMAT versus IMRT
    Bergman, A.
    Vollans, E.
    Duzenli, C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4630 - 4630
  • [47] A Dosimetric Comparison of Prostate Plans: IMRT, SmartArc, RapidArc and HybridArc
    Rule, W. G.
    Jiang, L.
    Boike, T.
    Anderson, J.
    Jain, S.
    Heinzerling, J.
    DeRose, P.
    Edwards, M.
    Tong, L.
    Solberg, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S847 - S847
  • [48] Dosimetric and radiobiological comparison of TomoTherapy and IMRT plans for prostate cancer
    Pourfarshid, Amin
    Mesbahi, Asghar
    Mohammadzadeh, Mohammad
    Molazadeh, Mikaeil
    Zeinali, Ahad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [49] Comparison of optimised treatment plans for radiosurgery and conformal radiotherapy
    Kulik, C
    Vermandel, M
    Gibon, D
    Caudrelier, JM
    Maouche, S
    Rousseau, J
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2520 - 2521
  • [50] Comparison of VMAT and IMRT for postoperative RT in prostate cancer patients with a rectal balloon
    Jung, H.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127