COMPARISON OF PROSTATE IMRT AND VMAT BIOLOGICALLY OPTIMISED TREATMENT PLANS

被引:60
|
作者
Hardcastle, Nicholas [1 ]
Tome, Wolfgang A.
Foo, Kerwyn
Miller, Andrew
Carolan, Martin
Metcalfe, Peter
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol & Med Phys, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
VMAT; IMRT; Prostate; Biological Optimisation; SINGLE-ARC IMRT; VOLUMETRIC MODULATED ARC; BIOL-PHYS; 2008/70996-1001; CONFORMAL RADIOTHERAPY; COMPLICATION PROBABILITY; RADIATION-THERAPY; CANCER; DELIVERY; MODELS; TRIAL;
D O I
10.1016/j.meddos.2010.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Recently, a new radiotherapy delivery technique has become clinically available-volumetric modulated arc therapy (VMAT). VMAT is the delivery of IMRT while the gantry is in motion using dynamic leaf motion. The perceived benefit of VMAT over IMRT is a reduction in delivery time. In this study, VMAT was compared directly with IMRT for a series of prostate cases. For 10 patients, a biologically optimized seven-field IMRT plan was compared with a biologically optimized VMAT plan using the same planning objectives. The Pinnacle RTPS was used. The resultant target and organ-at-risk dose-volume histograms (DVHs) were compared. The normal tissue complication probability (NTCP) for the IMRT and VMAT plans was calculated for 3 model parameter sets. The delivery efficiency and time for the IMRT and VMAT plans was compared. The VMAT plans resulted in a statistically significant reduction in the rectal V25Gy parameter of 8.2% on average over the DIRT plans. For one of the NTCP parameter sets, the VMAT plans had a statistically significant lower rectal NTCP. These reductions in rectal dose were achieved using 18.6% fewer monitor units and a delivery time reduction of up to 69%. VMAT plans resulted in reductions in rectal doses for all 10 patients in the study. This was achieved with significant reductions in delivery time and monitor units. Given the target coverage was equivalent, the VMAT plans were superior. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 50 条
  • [21] Comparison of IMRT and VMAT plans with different energy levels using Monte-Carlo algorithm for prostate cancer
    Cem Onal
    Gungor Arslan
    Cem Parlak
    Serhat Sonmez
    Japanese Journal of Radiology, 2014, 32 : 224 - 232
  • [22] Dosimetric and physical comparison of IMRT and CyberKnife plans in the treatment of localized prostate cancer
    Ceylan, Cemile
    Kucuk, Nadir
    Bas Ayata, Hande
    Kilic, Ayhan
    Guden, Metin
    Engin, Kayihan
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2010, 25 (03): : 93 - 103
  • [23] Comparison of Prostate IMRT Plans From Three Commercial Treatment Planning Systems
    Chi, Z.
    Wang, L.
    Chen, L.
    Fan, J.
    Jin, L.
    Ma, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [24] Dosimetric and physical comparison of IMRT and CyberKnife plans in the treatment of localized prostate cancer
    Ceylan, Cemile
    Kucuk, Nadir
    Ayata, Hande Bas
    Guden, Metin
    Engin, Kayihan
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (06) : 181 - 189
  • [25] A Comparison of VMAT and IMRT Treatment Plans for Four Clinical Sites at a Mixed-Machine Cancer Center
    Schnell, E.
    Ahmad, S.
    Thompson, S.
    Algan, O.
    Bogardus, C.
    Herman, T.
    Herman, T. De La Fuente
    MEDICAL PHYSICS, 2017, 44 (06) : 2915 - 2915
  • [26] VMAT planning for Elekta linacs in the Varian planning system eclipse: a comparison study of VMAT plans with fixed field IMRT plans
    Peters, S.
    Schiefer, H.
    Socoliuc, A.
    Plasswilm, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1077 - 1077
  • [27] A dosimetric comparison of treatment plans by using aaa/mc with vmat technique for prostate patients
    Boydak, P.
    Temizyurek, K.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S821 - S821
  • [28] Accuracy of portal dosimetry in hybrid IMRT and VMAT treatment of the prostate
    Bedford, J.
    Hanson, I.
    Smyth, G.
    Tree, A.
    Dearnaley, D.
    Hansen, V. N.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S7 - S8
  • [29] Dosimetric comparison of IMRT, VMAT and HYBRID treatment methods in radical radiation therapy of prostate cancer
    Ozturk, N.
    Ozbek, N.
    Depboylu, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 411 - 416
  • [30] Evaluation of Dose-Volume Variability and Parameters Between Prostate IMRT and VMAT Plans
    Chow, J.
    Jiang, R.
    Kiciak, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3550 - 3550