COMPARISON OF PROSTATE IMRT AND VMAT BIOLOGICALLY OPTIMISED TREATMENT PLANS

被引:60
|
作者
Hardcastle, Nicholas [1 ]
Tome, Wolfgang A.
Foo, Kerwyn
Miller, Andrew
Carolan, Martin
Metcalfe, Peter
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol & Med Phys, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
VMAT; IMRT; Prostate; Biological Optimisation; SINGLE-ARC IMRT; VOLUMETRIC MODULATED ARC; BIOL-PHYS; 2008/70996-1001; CONFORMAL RADIOTHERAPY; COMPLICATION PROBABILITY; RADIATION-THERAPY; CANCER; DELIVERY; MODELS; TRIAL;
D O I
10.1016/j.meddos.2010.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Recently, a new radiotherapy delivery technique has become clinically available-volumetric modulated arc therapy (VMAT). VMAT is the delivery of IMRT while the gantry is in motion using dynamic leaf motion. The perceived benefit of VMAT over IMRT is a reduction in delivery time. In this study, VMAT was compared directly with IMRT for a series of prostate cases. For 10 patients, a biologically optimized seven-field IMRT plan was compared with a biologically optimized VMAT plan using the same planning objectives. The Pinnacle RTPS was used. The resultant target and organ-at-risk dose-volume histograms (DVHs) were compared. The normal tissue complication probability (NTCP) for the IMRT and VMAT plans was calculated for 3 model parameter sets. The delivery efficiency and time for the IMRT and VMAT plans was compared. The VMAT plans resulted in a statistically significant reduction in the rectal V25Gy parameter of 8.2% on average over the DIRT plans. For one of the NTCP parameter sets, the VMAT plans had a statistically significant lower rectal NTCP. These reductions in rectal dose were achieved using 18.6% fewer monitor units and a delivery time reduction of up to 69%. VMAT plans resulted in reductions in rectal doses for all 10 patients in the study. This was achieved with significant reductions in delivery time and monitor units. Given the target coverage was equivalent, the VMAT plans were superior. (C) 2011 American Association of Medical Dosimetrists.
引用
收藏
页码:292 / 298
页数:7
相关论文
共 50 条
  • [1] VMAT PLANS FOR TREATMENT OF PROSTATE CANCER: DOSIMETRIC VERIFICATIONS AND COMPARISON WITH IMRT
    Masi, L.
    Doro, R.
    Casamassima, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S197 - S198
  • [2] Quality of treatment plans in hybrid IMRT and VMAT for prostate radiotherapy
    Bedford, J.
    Smyth, G.
    Hanson, I.
    Tree, A.
    Dearnaley, D.
    Hansen, V.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S219 - S220
  • [3] Dosimetric comparison of MR-linac-based IMRT and conventional VMAT treatment plans for prostate cancer
    Vanessa Da Silva Mendes
    Lukas Nierer
    Minglun Li
    Stefanie Corradini
    Michael Reiner
    Florian Kamp
    Maximilian Niyazi
    Christopher Kurz
    Guillaume Landry
    Claus Belka
    Radiation Oncology, 16
  • [4] Dosimetric comparison of MR-linac-based IMRT and conventional VMAT treatment plans for prostate cancer
    Mendes, Vanessa Da Silva
    Nierer, Lukas
    Li, Minglun
    Corradini, Stefanie
    Reiner, Michael
    Kamp, Florian
    Niyazi, Maximilian
    Kurz, Christopher
    Landry, Guillaume
    Belka, Claus
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [5] Dose comparisons for conformal, IMRT and VMAT prostate plans
    Sale, Charlotte
    Moloney, Phillip
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (06) : 611 - 621
  • [6] A Comprehensive Comparison of IMRT and VMAT Plan Quality for Prostate Cancer Treatment
    Quan, Enzhuo M.
    Li, Xiaoqiang
    Li, Yupeng
    Wang, Xiaochun
    Kudchadker, Rajat J.
    Johnson, Jennifer L.
    Kuban, Deborah A.
    Lee, Andrew K.
    Zhang, Xiaodong
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : 1169 - 1178
  • [7] A comparison of proton therapy and IMRT treatment plans for prostate radiotherapy
    S. J. Dowdell
    P. E. Metcalfe
    J. E. Morales
    M. Jackson
    A. B. Rosenfeld
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 325 - 331
  • [8] A comparison of proton therapy and IMRT treatment plans for prostate radiotherapy
    Dowdell, S. J.
    Metcalfe, P. E.
    Morales, J. E.
    Jackson, M.
    Rosenfeld, A. B.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (04) : 325 - 331
  • [9] Dosimetric comparison of treatment plans for pancreatic cancer: 3DCRT, IMRT and VMAT
    Trecca, P.
    Fiore, M.
    Floreno, B.
    D'Angelillo, R.
    Trodella, L.
    Mameli, A.
    Infusino, E.
    Greco, C.
    Trodella, L.
    Ramella, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S852 - S853
  • [10] Comparison of treatment plans between IMRT with MR-linac and VMAT for lung SABR
    Jong Min Park
    Hong-Gyun Wu
    Hak Jae Kim
    Chang Heon Choi
    Jung-in Kim
    Radiation Oncology, 14