Fine scale resolution of ceramic microstructures by X-ray computed tomography: An economical approach

被引:0
|
作者
Huss, SP [1 ]
Gray, JN [1 ]
Schilling, CH [1 ]
机构
[1] Iowa State Univ, Ames Lab, Ames, IA 50010 USA
来源
关键词
D O I
暂无
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
High-magnification, 3-dimensional imaging of ceramics by x-ray computed tomography (CT) typically requires use of a synchrotron and / or a massive array of solid-state detectors. The high cost of this research equipment generally limits its use as a process-development tool by ceramic manufacturers. In this paper, we demonstrate a more economical approach which produces image quality comparable to that of standard, high performance equipment. In this method we utilized an inexpensive image intensifier and applied techniques of frame averaging, gray-scale sub-ranging and other noise reduction and artifact removal methods in order to improve contrast sensitivity while maintaining low cost. After discussing critical factors affecting image quality, we discuss cost / performance tradeoffs associated with different CT equipment options.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [41] The application of high-resolution X-ray computed tomography to ore deposits
    Godel, Belinda
    Barnes, Stephen J.
    MINERAL DEPOSIT RESEARCH FOR A HIGH-TECH WORLD, VOLS. 1-4, 2013, : 191 - 193
  • [42] Deep Learning for High Spatial Resolution X-Ray Luminescence Computed Tomography
    Dai, X.
    Cheng, K.
    Zhao, W.
    Xing, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E566 - E566
  • [43] Real-time High-resolution X-Ray Computed Tomography
    Wu, Du
    Chen, Peng
    Wang, Xiao
    Lyngaas, Issac
    Miyajima, Takaaki
    Endo, Toshio
    Matsuoka, Satoshi
    Wahib, Mohamed
    PROCEEDINGS OF THE 38TH ACM INTERNATIONAL CONFERENCE ON SUPERCOMPUTING, ACM ICS 2024, 2024, : 110 - 123
  • [44] High-resolution computed tomography with a compact soft x-ray microscope
    Bertilson, Michael
    von Hofsten, Olov
    Vogt, Ulrich
    Holmberg, Anders
    Hertz, Hans M.
    OPTICS EXPRESS, 2009, 17 (13): : 11057 - 11065
  • [45] X-RAY COMPUTED-TOMOGRAPHY WITH 50-MU-M RESOLUTION
    SEGUIN, FH
    BURSTEIN, P
    BJORKHOLM, PJ
    HOMBURGER, F
    ADAMS, RA
    APPLIED OPTICS, 1985, 24 (23): : 4117 - 4123
  • [46] Data fusion in X-ray computed tomography using a superiorization approach
    Schrapp, Michael J.
    Herman, Gabor T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (05):
  • [47] A Multiresolution Approach to Iterative Reconstruction Algorithms in X-Ray Computed Tomography
    De Witte, Yoni
    Vlassenbroeck, Jelle
    Van Hoorebeke, Luc
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2010, 19 (09) : 2419 - 2427
  • [48] Plant structure visualization by high-resolution X-ray computed tomography
    Dhondt, Stijn
    Vanhaeren, Hannes
    Van Loo, Denis
    Cnudde, Veerle
    Inze, Dirk
    TRENDS IN PLANT SCIENCE, 2010, 15 (08) : 419 - 422
  • [49] Resolution for radar and x-ray tomography
    Natterer, F
    Cheney, M
    Borden, B
    INVERSE PROBLEMS, 2003, 19 (06) : S55 - S63
  • [50] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)