Convective heat transfer coefficients in a full-scale room with and without furniture

被引:30
|
作者
Wallentén, P [1 ]
机构
[1] Lund Inst Technol, Dept Bldg Sci, S-22100 Lund, Sweden
关键词
heat transfer; convective; coefficient; envelope; energy; model; in situ measurements; wall; window; temperature dependency; air; thermocouples;
D O I
10.1016/S0360-1323(00)00070-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The convective heat transfer coefficient at an outer ambient wall with a window exposed to natural climate was measured in a room with and without furniture. The method used was to estimate the heat flow from measured temperatures and solar radiation. The convective heat transfer was calculated as the difference between the heat flow through the building element and the calculated long-wave radiation. Even though the accuracy was at best +/- 15%, the effect of different heating and ventilation strategies could clearly be detected. Local coefficients may be more than 10 times the expected, due to ventilation or position of the radiator. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 50 条
  • [31] FULL-SCALE CONTROLLED TRANSIENT HEAT TRANSFER TESTS - DATA REPORT - 1.
    Anon
    Electric Power Research Institute (Report) EPRI NP, 1981, 1 (1810):
  • [32] HEAT-TRANSFER IN NATURALLY VENTILATED ROOMS - DATA FROM FULL-SCALE MEASUREMENTS
    CHANDRA, S
    KERESTECIOGLU, AA
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 55 - 55
  • [33] Influences of street aspect ratios and realistic solar heating on convective heat transfer and ventilation in full-scale 2D street canyons
    Yang, Hongyu
    Chen, Guanwen
    Wang, Dongyang
    Hang, Jian
    Li, Qi
    Wang, Qun
    BUILDING AND ENVIRONMENT, 2021, 204
  • [34] Intercomparisons of Experimental Convective Heat Transfer Coefficients and Mass Transfer Coefficients of Urban Surfaces
    Aya Hagishima
    Jun Tanimoto
    Ken-ich Narita
    Boundary-Layer Meteorology, 2005, 117 : 551 - 576
  • [35] Intercomparisons of experimental convective heat transfer coefficients and mass transfer coefficients of urban surfaces
    Hagishima, A
    Tanimoto, J
    Narita, K
    BOUNDARY-LAYER METEOROLOGY, 2005, 117 (03) : 551 - 576
  • [36] Airflow characteristics by air curtain jets in full-scale room
    尹海国
    李安桂
    JournalofCentralSouthUniversity, 2012, 19 (03) : 675 - 681
  • [37] Airflow characteristics by air curtain jets in full-scale room
    Hai-guo Yin
    An-gui Li
    Journal of Central South University, 2012, 19 : 675 - 681
  • [38] Convective Mach Number and Full-Scale Supersonic Jet Noise Directivity
    Gee, Kent L.
    Olaveson, Tyce W.
    Mathews, Logan T.
    AIAA JOURNAL, 2025, 63 (04) : 1393 - 1404
  • [39] Airflow characteristics by air curtain jets in full-scale room
    Yin Hai-guo
    Li An-gui
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 675 - 681
  • [40] Measurements of air flow characteristics in a full-scale clean room
    Hu, SC
    Wu, YY
    Liu, CJ
    BUILDING AND ENVIRONMENT, 1996, 31 (02) : 119 - 128