Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy

被引:12
|
作者
Kim, B
Kron, T
Battista, J
Van Dyk, J
机构
[1] London Reg Canc Program, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
[3] Univ Western Ontario, Dept Oncol, London, ON N6A 4L6, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 10期
关键词
D O I
10.1088/0031-9155/50/10/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Loose helical delivery is a potential solution to account for respiration-driven tumour motion in helical tomotherapy (HT). In this approach, a treatment is divided into a set of interlaced 'loose' helices commencing at different gantry angles. Each loose helix covers the entire target length in one gantry rotation during a single breath-hold. The dosimetric characteristics of loose helical delivery were investigated by delivering a 6 MV photon beam in a HT-like manner. Multiple scenarios of conventional 'tight' HT and loose helical deliveries were modelled in treatment planning software, and carried out experimentally with Kodak EDR2 film. The advantage of loose helical delivery lies in its ability to produce a more homogeneous dose distribution by eliminating the 'thread' effect-an inherent characteristic of HT, which results in dose modulations away from the axis of gantry rotation. However, loose helical delivery was also subjected to undesirable dose modulations in the direction of couch motion (termed 'beating' effect), when the ratio between the number of beam projections per gantry rotation (n) and pitch factor (p) was a non-integer. The magnitude of dose modulations decreased with an increasing n/p ratio. The results suggest that for the current HT unit (n = 51), dose modulations could be kept under 5% by selecting a pitch factor smaller than 7. A pitch factor of this magnitude should be able to treat a target up to 30 cm in length. Loose helical delivery should increase the total session time only by a factor of 2, while the planning time should stay the same since the total number of beam projections remains unchanged. Considering its dosimetric advantage and clinical practicality, loose helical delivery is a promising solution for the future HT treatments of respiration-driven targets.
引用
收藏
页码:2387 / 2404
页数:18
相关论文
共 50 条
  • [41] Deep-Inspiration Breath-Hold Intensity Modulated Radiation Therapy to the Mediastinum for Lymphoma Patients: Setup Uncertainties and Margins
    Aristophanous, Michalis
    Chi, Pai-Chun M.
    Kao, Jeremy
    Williamson, Ryan
    Tung, Sam
    Andraos, Therese
    Milgrom, Sarah A.
    Pinnix, Chelsea C.
    Dabaja, Bouthaina S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 254 - 262
  • [42] Online verification of breath-hold reproducibility using kV-triggered imaging for liver stereotactic body radiation therapy
    Guo, Bingqi
    Stephans, Kevin
    Woody, Neil
    Antolak, Alexander
    Moazzezi, Mojtaba
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [43] INTENSITY-MODULATED RADIATION THERAPY FOR CRANIOSPINAL IRRADIATION USING HELICAL TOMOTHERAPY: FROM PLANNING TO DELIVERY
    Gupta, Tejpal
    Zade, Bhooshan
    Jalali, Rakesh
    Master, Zubin
    Phurailatpam, Reena
    Munshi, Anusheel
    Sarin, Rajiv
    NEURO-ONCOLOGY, 2009, 11 (06) : 914 - 915
  • [44] Image-guided dose-escalated radiation therapy for localized prostate cancer with helical tomotherapy
    Tomasz Barelkowski
    Peter Wust
    David Kaul
    Sebastian Zschaeck
    Waldemar Wlodarczyk
    Volker Budach
    Pirus Ghadjar
    Marcus Beck
    Strahlentherapie und Onkologie, 2020, 196 : 229 - 242
  • [45] Fast radiographic film calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification
    Yan, YL
    Papanikolaou, N
    Weng, XJ
    Penagaricano, J
    Ratanatharathorn, V
    MEDICAL PHYSICS, 2005, 32 (06) : 1566 - 1570
  • [46] Image-guided dose-escalated radiation therapy for localized prostate cancer with helical tomotherapy
    Barelkowski, Tomasz
    Wust, Peter
    Kaul, David
    Zschaeck, Sebastian
    Wlodarczyk, Waldemar
    Budach, Volker
    Ghadjar, Pirus
    Beck, Marcus
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (03) : 229 - 242
  • [47] Impact of tumor position displacement during end-exhalation breath-hold condition on tumor dose in lung stereotactic body radiation therapy using volumetric modulated arc therapy
    Kamima, Tatsuya
    Moriya, Shunsuke
    Sakae, Takeji
    Miyauchi, Hikaru
    Ito, Yasushi
    Tokumasu, Kenji
    Yoshioka, Yasuo
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2025, 51
  • [48] Ventilation Imaging for Lung Radiation Therapy Planning: Free Breathing 4DCT vs. Breath-Hold MRI
    Ding, K.
    Cao, K.
    Du, K.
    Chen, Q.
    Ennis, D.
    Christensen, G.
    Reinhardt, J.
    Libby, B.
    Benedict, S.
    Sheng, K.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S325 - S325
  • [49] Protocol of a study investigating breath-hold techniques for upper-abdominal radiation therapy (BURDIE): addressing the challenge of a moving target
    Farrugia, Briana
    Khor, Richard
    Foroudi, Farshad
    Chao, Michael
    Knight, Kellie
    Wright, Caroline
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [50] Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    Betgen, Anja
    Honnef, Joeri
    van Vliet-Vroegindeweij, Corine
    Remeijer, Peter
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 536 - 542