Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy

被引:12
|
作者
Kim, B
Kron, T
Battista, J
Van Dyk, J
机构
[1] London Reg Canc Program, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
[3] Univ Western Ontario, Dept Oncol, London, ON N6A 4L6, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 10期
关键词
D O I
10.1088/0031-9155/50/10/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Loose helical delivery is a potential solution to account for respiration-driven tumour motion in helical tomotherapy (HT). In this approach, a treatment is divided into a set of interlaced 'loose' helices commencing at different gantry angles. Each loose helix covers the entire target length in one gantry rotation during a single breath-hold. The dosimetric characteristics of loose helical delivery were investigated by delivering a 6 MV photon beam in a HT-like manner. Multiple scenarios of conventional 'tight' HT and loose helical deliveries were modelled in treatment planning software, and carried out experimentally with Kodak EDR2 film. The advantage of loose helical delivery lies in its ability to produce a more homogeneous dose distribution by eliminating the 'thread' effect-an inherent characteristic of HT, which results in dose modulations away from the axis of gantry rotation. However, loose helical delivery was also subjected to undesirable dose modulations in the direction of couch motion (termed 'beating' effect), when the ratio between the number of beam projections per gantry rotation (n) and pitch factor (p) was a non-integer. The magnitude of dose modulations decreased with an increasing n/p ratio. The results suggest that for the current HT unit (n = 51), dose modulations could be kept under 5% by selecting a pitch factor smaller than 7. A pitch factor of this magnitude should be able to treat a target up to 30 cm in length. Loose helical delivery should increase the total session time only by a factor of 2, while the planning time should stay the same since the total number of beam projections remains unchanged. Considering its dosimetric advantage and clinical practicality, loose helical delivery is a promising solution for the future HT treatments of respiration-driven targets.
引用
收藏
页码:2387 / 2404
页数:18
相关论文
共 50 条
  • [1] The dosimetric effects of the breath-hold technique for helical tomotherapy
    Yamamoto, M.
    Endo, T.
    Koshi, N.
    Masumoto, K.
    Tanemura, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S190 - S191
  • [2] Use of breath-hold helical CT and spirometry in conformal radiation therapy planning
    Hanley, J
    DeBois, MM
    Schwartz, LH
    Raben, A
    Magolas, GS
    Kutcher, GJ
    RADIOLOGY, 1996, 201 : 1506 - 1506
  • [3] Gating and breath-hold techniquess in Radiation Therapy
    Aznar, M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S3 - S3
  • [4] Margin optimization for fractionated breath-hold radiation therapy
    O'Dell, W
    Schell, M
    Okunieff, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1210 - 1210
  • [5] The Feasibility of Implementing Deep Inspiration Breath-Hold for Pediatric Radiation Therapy
    Lundgaard, Anni Young
    Josipovic, Mirjana
    Rechner, Laura Ann
    Bidstrup, Pernille Envold
    Hansen, Rune
    Damkjaer, Sidsel Skov
    Joergensen, Morten
    Safwat, Akmal
    Specht, Lena
    Hjalgrim, Lisa Lyngsie
    Maraldo, Maja Vestmoe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (05): : 977 - 984
  • [6] Feasibility of a feedback-guided breath-hold technique for thoracic radiation therapy
    Kainz, K.
    Liu, H.
    Balter, P.
    Tutt, T.
    Hunjan, S.
    Prado, K.
    Liao, Z.
    MEDICAL PHYSICS, 2006, 33 (06) : 2035 - 2035
  • [7] Deep Inspiration Breath-Hold Radiation Therapy Reduces Radiation Dose to the Lungs and Heart in Patients Treated for Mediastinal Hodgkin Lymphoma
    Petersen, P. M.
    Aznar, M. C.
    Berthelsen, A. K.
    Jacobsen, A. L.
    Schut, D. A.
    Maraldo, M. V.
    Klausen, T. L.
    Andersen, F.
    Specht, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S62 - S62
  • [8] Dosimetric impact of breath-hold in the treatment of hepatocellular carcinoma by conformal radiation therapy
    Kubas, A.
    Chapet, O.
    Merle, P.
    Lorchel, F.
    d'Hombres, A.
    Mornex, F.
    CANCER RADIOTHERAPIE, 2009, 13 (01): : 24 - 29
  • [9] Dosimetric comparison of the breath-hold based and conventional radiation therapy of lung cancer.
    Choi, A. H.
    Chung, K. Z.
    Park, B. S.
    Park, J. H.
    Pyo, H. R.
    Choi, B. K.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S560 - S560
  • [10] Gated deep inspiration breath-hold radiation therapy using a linear position transducer
    Yewondwossen, M
    Denissova, S
    Andrew, J
    Hale, M
    Murph, C
    Purcell, S