Determination of Trace Copper in Water Samples by Anodic Stripping Voltammetry at Gold Microelectrode

被引:0
|
作者
Zhuang, Jianmei [1 ]
Zhang, Li [2 ,3 ,4 ]
Lu, Wenjing [2 ,3 ,4 ]
Shen, Dazhong [1 ]
Zhu, Rilong [5 ]
Pan, Dawei [2 ,3 ]
机构
[1] Shangdong Normal Univ, Key Lab Mol & Nanomat Probes, Minist Educ China, Coll Chem Chem Engn & Mat Sci, Jinan 250014, Peoples R China
[2] Chinese Acad Sci, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res, Yantai 264003, Peoples R China
[3] Chinese Acad Sci, CAS, Yantai Inst Coastal Zone Res, Yantai 264003, Peoples R China
[4] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
[5] Hunan Prov Environm Monitoring Ctr, Changsha 410014, Hunan, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Gold microelectrode; Copper; Anodic stripping voltammetry; Water samples; CARBON ELECTRODES; NATURAL-WATERS; SILICA; ELECTROCHEMISTRY; PRECONCENTRATION; ARRAYS; METALS; CU(II); IONS; ACID;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The applicability of gold microelectrode of 25 mu m diameter for electrochemical determination of trace copper ions (Cu2+) in water samples by anodic stripping voltammetry (ASV) has been demonstrated. The analysis of Cu2+ at gold microelectrode includes two steps. Cu2+ ions are firstly reduced and accumulated on the microelectrode surface during an accumulation step, then oxidized during the positive potential sweep. Due to the rapid mass transporting and low background current of gold microelectrode, low detection limit (0.3 nM) and wide linear range (1.0-90 nM) can be obtained. The practical application of gold microelectrode was verified by determination of trace level of Cu2+ in tap water, lake water and commercial drinking water samples.
引用
收藏
页码:4690 / 4699
页数:10
相关论文
共 50 条
  • [41] Determination of trace lead in copper by cathodic stripping voltammetry
    Faculty of Engineering, Science University of Tokyo, Kagurazaka, Shinjuku, Tokyo 162, Japan
    Anal. Sci., 2 (263-265):
  • [42] Determination of trace lead in copper by cathodic stripping voltammetry
    Ishiyama, T
    Abe, K
    Tanaka, T
    Mizuike, A
    ANALYTICAL SCIENCES, 1996, 12 (02) : 263 - 265
  • [43] Determination of trace amounts of copper by adsorptive stripping voltammetry
    Shams, E
    ANALYTICAL LETTERS, 2000, 33 (03) : 465 - 478
  • [44] Simultaneous determination of cadmium, lead and copper in chocolate samples by square wave anodic stripping voltammetry
    Silva, Larissa Pinto
    Campos, Naira Da Silva
    Lisboa, Thalles Pedrosa
    de Faria, Lucas Vinicius
    Matos, Maria Auxiliadora Costa
    Matos, Renato Camargo
    de Sousa, Rafael Arromba
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (03): : 418 - 426
  • [45] DETERMINATION OF ARSENIC BY ANODIC STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
    OLAUGHLI.JW
    FORSBERG, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, (AUG26): : 34 - 34
  • [46] DETERMINATION OF SELENIUM AND TELLURIUM IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE
    HAMILTON, TW
    ELLIS, J
    FLORENCE, TM
    ANALYTICA CHIMICA ACTA, 1979, 110 (01) : 87 - 94
  • [47] Selective determination of trace copper by extraction-anodic stripping voltammetry of copper(II) acetylacetonate in nonaqueous media
    Pournaghi-Azar, MH
    Ramazani, MR
    ELECTROANALYSIS, 2002, 14 (17) : 1203 - 1208
  • [48] DETERMINATION OF ARSENIC AND ANTIMONY IN ELECTROLYTIC COPPER BY ANODIC-STRIPPING VOLTAMMETRY AT A GOLD FILM ELECTRODE
    HAMILTON, TW
    ELLIS, J
    FLORENCE, TM
    ANALYTICA CHIMICA ACTA, 1980, 119 (02) : 225 - 233
  • [49] DETERMINATION OF COPPER BY ANODIC-STRIPPING VOLTAMMETRY - ANOMALOUS BEHAVIOR IN SEA-WATER
    SIEBERT, RJ
    HUME, DN
    ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) : 335 - 338
  • [50] DETERMINATION OF COPPER AND LEAD IN SCHIST BY ANODIC-STRIPPING VOLTAMMETRY
    LUND, W
    SALBERG, M
    TALANTA, 1975, 22 (12) : 1013 - 1016