Wear Comparison Between a Highly Cross-Linked Polyethylene and Conventional Polyethylene Against a Zirconia Femoral Head Minimum 5-Year Follow-Up

被引:17
|
作者
Fukui, Kiyokazu [1 ]
Kaneuji, Ayumi [1 ]
Sugimori, Tanzo [1 ]
Ichiseki, Toru [1 ]
Kitamura, Kenji [1 ]
Matsumoto, Tadami [1 ]
机构
[1] Kanazawa Med Univ, Dept Orthoped Surg, Kanazawa, Ishikawa, Japan
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 01期
关键词
cross-linked polyethylene; polyethylene wear; total hip arthroplasty; zirconia femoral head; TOTAL HIP-ARTHROPLASTY; CERAMIC HEAD; RADIOSTEREOMETRIC ANALYSIS; UNCEMENTED SOCKETS; ALUMINA; FRACTURE; JOINTS; METAL; REPLACEMENT; SIMULATOR;
D O I
10.1016/j.arth.2009.11.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Highly cross-linked polyethylene (HXLPE) was developed to reduce wear of articular bearing surface in total hip arthroplasty patients. Several studies have shown reduced wear of HXLPE compared with conventional polyethylene; however, these studies had used HXLPE in combination with a Co-Cr metal head. The purpose of this study was to compare the 5-year in vivo wear of HXLPE with that of conventional PE using a zirconia femoral head. Forty-five hips with a Trilogy HXLPE (Zimmer, Warsaw, Ind) were matched and compared with a control group of 20 conventional Trilogy PE hips. The 2-dimensional linear wear rate was significantly less in the HXLPE group between 1 and 5 years postoperation (P < .001). The results show that HXLPE reduces short-term polyethylene wear against not only a Co-Cr head but also a zirconia head.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [31] Wear resistance of the biocompatible phospholipid polymer-grafted highly cross-linked polyethylene liner against larger femoral head
    Moro, Toru
    Takatori, Yoshio
    Kyomoto, Masayuki
    Ishihara, Kazuhiko
    Kawaguchi, Hiroshi
    Hashimoto, Masami
    Tanaka, Takeyuki
    Oshima, Hirofumi
    Tanaka, Sakae
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (07) : 1103 - 1110
  • [32] Wear Kinetics of Highly Cross-Linked and Conventional Polyethylene Are Similar at Medium-term Follow-Up After Primary Total Hip Arthroplasty
    Mayer, Constantin
    Rommelmann, Moritz
    Behringer, Michael
    Jaeger, Marcus
    Krauspe, Ruediger
    Zilkens, Christoph
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2671 - 2676
  • [33] High rate of tibial post-fracture in highly cross-linked polyethylene compared to conventional polyethylene in posterior-stabilized total knee arthroplasty at a minimum 12-year follow-up
    Ji-Hoon Baek
    Su Chan Lee
    Kyungwon Choi
    Chang Hyun Nam
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 4072 - 4077
  • [34] High rate of tibial post-fracture in highly cross-linked polyethylene compared to conventional polyethylene in posterior-stabilized total knee arthroplasty at a minimum 12-year follow-up
    Baek, Ji-Hoon
    Lee, Su Chan
    Choi, Kyungwon
    Nam, Chang Hyun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (12) : 4072 - 4077
  • [35] Up to 18-Year Follow-Up Wear Analysis of a First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Feng, James E.
    Novikov, David
    Chen, Kevin
    Kim, Kelvin
    Bookman, Jared
    Anoushiravani, Afshin A.
    Hamula, Matthew
    Snir, Nimrod
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10): : 3325 - 3328
  • [36] Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up
    Tsukamoto, Manabu
    Mori, Toshiharu
    Ohnishi, Hideo
    Uchida, Soshi
    Sakai, Akinori
    JOURNAL OF ARTHROPLASTY, 2017, 32 (12): : 3771 - 3776
  • [37] Wear and osteolysis outcomes for highly cross-linked polyethylene in primary total hip arthroplasty compared with conventional polyethylene: a 15-to 18-year single-centre follow-up study
    Moon, Nam Hoon
    Shin, Won Chul
    Uk, Min
    Kang, Suk-Woong
    Lee, Sang-Min
    Suh, Kuen Tak
    HIP INTERNATIONAL, 2021, 31 (04) : 526 - 532
  • [38] Early femoral head penetration of a highly cross-linked polyethylene liner vs a conventional polyethylene liner - A case-controlled study
    Krushell, RJ
    Fingeroth, RJ
    Cushing, MC
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 73 - 76
  • [39] Ten-to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear?
    Cheung, Amy
    Yan, Chun Hoi
    Fu, Henry
    Cheung, Man Hong
    Chan, Ping Keung
    Chiu, Kwong Yuen
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09): : 2016 - 2021
  • [40] Wear Rates With Large Metal and Ceramic Heads on a Second Generation Highly Cross-Linked Polyethylene at Mean 6-Year Follow-Up
    Gaudiani, Michael A.
    White, Peter B.
    Ghazi, Narges
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 590 - 594