Wear Comparison Between a Highly Cross-Linked Polyethylene and Conventional Polyethylene Against a Zirconia Femoral Head Minimum 5-Year Follow-Up

被引:17
|
作者
Fukui, Kiyokazu [1 ]
Kaneuji, Ayumi [1 ]
Sugimori, Tanzo [1 ]
Ichiseki, Toru [1 ]
Kitamura, Kenji [1 ]
Matsumoto, Tadami [1 ]
机构
[1] Kanazawa Med Univ, Dept Orthoped Surg, Kanazawa, Ishikawa, Japan
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 01期
关键词
cross-linked polyethylene; polyethylene wear; total hip arthroplasty; zirconia femoral head; TOTAL HIP-ARTHROPLASTY; CERAMIC HEAD; RADIOSTEREOMETRIC ANALYSIS; UNCEMENTED SOCKETS; ALUMINA; FRACTURE; JOINTS; METAL; REPLACEMENT; SIMULATOR;
D O I
10.1016/j.arth.2009.11.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Highly cross-linked polyethylene (HXLPE) was developed to reduce wear of articular bearing surface in total hip arthroplasty patients. Several studies have shown reduced wear of HXLPE compared with conventional polyethylene; however, these studies had used HXLPE in combination with a Co-Cr metal head. The purpose of this study was to compare the 5-year in vivo wear of HXLPE with that of conventional PE using a zirconia femoral head. Forty-five hips with a Trilogy HXLPE (Zimmer, Warsaw, Ind) were matched and compared with a control group of 20 conventional Trilogy PE hips. The 2-dimensional linear wear rate was significantly less in the HXLPE group between 1 and 5 years postoperation (P < .001). The results show that HXLPE reduces short-term polyethylene wear against not only a Co-Cr head but also a zirconia head.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [21] Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
    Fortunato Giustra
    Alessandro Bistolfi
    Francesco Bosco
    Nicolò Fresia
    Luigi Sabatini
    Paola Berchialla
    Veronica Sciannameo
    Alessandro Massè
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1082 - 1088
  • [22] Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
    Giustra, Fortunato
    Bistolfi, Alessandro
    Bosco, Francesco
    Fresia, Nicolo
    Sabatini, Luigi
    Berchialla, Paola
    Sciannameo, Veronica
    Masse, Alessandro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 1082 - 1088
  • [23] No Revisions Attributable to Wear of Highly Cross-Linked Polyethylene Liners: A Long-Term Follow-Up Study
    Wright, Breydan H.
    Hadley, Matthew L.
    Harmer, Joshua R.
    Fruth, Kristin M.
    Sierra, Rafael J.
    Couch, Cory G.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S347 - S352
  • [24] Femoral head sizes larger than 32 mm against highly cross-linked polyethylene
    Burroughs, BR
    Rubash, HE
    Harris, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) : 150 - 157
  • [25] Primary THA Using Thin Polyethylene Liners and Large Femoral Heads: A Minimum 5-Year Follow-Up
    Hagman, Dallas S.
    Smith, Austin F.
    Presley, Terry L.
    Smith, Langan S.
    Yakkanti, Madhusudhan R.
    Price, Matthew R.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S588 - S591
  • [26] High survivorship of highly cross-linked polyethylene in revision Total hip Arthroplasty: a minimum 10-year follow-up study
    Seung-Jae Lim
    Ingwon Yeo
    Chan-Woo Park
    Kyung-Jae Lee
    Byung-Woo Min
    Youn-Soo Park
    Arthroplasty, 1
  • [27] High survivorship of highly cross-linked polyethylene in revision Total hip Arthroplasty: a minimum 10-year follow-up study
    Lim, Seung-Jae
    Yeo, Ingwon
    Park, Chan-Woo
    Lee, Kyung-Jae
    Min, Byung-Woo
    Park, Youn-Soo
    ARTHROPLASTY, 2019, 1 (01)
  • [28] Low Wear at 10-Year Follow-Up of a Second-Generation Highly Cross-Linked Polyethylene in Total Hip Arthroplasty
    Sax, Oliver C.
    Douglas, Scott J.
    Chen, Zhongming
    Mont, Michael A.
    Nace, James
    Delanois, Ronald E.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S592 - S597
  • [29] In vivo wear of large femoral heads on highly cross-linked polyethylene.
    Aspey, B
    Beaulé, PE
    Martell, J
    Ebramzadeh, E
    Amstutz, HC
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S114 - S114
  • [30] Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?
    Glyn-Jones, Sion
    Saac, Sherif
    Hauptfleisch, Jennifer
    McLardy-Smith, Peter
    Murray, David W.
    Singh, Harinderjit
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 337 - 343