Balloon expandable aortic stent-graft for the treatment of aortic aneurysm and rupture in a dog

被引:0
|
作者
Klainbart, Sigal [1 ]
Segev, Gilad [2 ]
Chen, Hilla [2 ]
Peery, Dana [3 ]
Shipov, Anna [4 ]
机构
[1] Hebrew Univ Jerusalem, Dept Small Anim Emergency & Crit Care, Vet Teaching Hosp, Koret Sch Vet Med, POB 12, IL-761001 Rehovot, Israel
[2] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Small Anim Internal Med, Koret Sch Vet Med, Rehovot, Israel
[3] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Diagnost Imaging, Koret Sch Vet Med, Rehovot, Israel
[4] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Small Anim Surg, Koret Sch Vet Med, Rehovot, Israel
关键词
aortic dissection; endovascular stent; Spirocerca lupi; TEVAR; ENDOVASCULAR REPAIR; RATIONAL USE; DISSECTION; MANAGEMENT; ANTITHROMBOTICS; CONSENSUS; SURGERY; LUPI;
D O I
10.1111/vec.13102
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To describe the successful placement of an aortic stent graft in a dog suffering from aortic aneurysm and rupture. Case summary A 4-year-old neutered female mixed breed dog weighing 25 kg was presented with a chief complaint of acute onset of weakness and respiratory distress. On presentation, the dog was lateral and unresponsive, hypothermic, tachycardic, and tachypneic. Pleural effusion was identified in the right hemi-thorax on thoracic-focused sonographic scan for trauma. Thoracic radiographs showed a fluid/soft tissue opacity in the cranial mediastinum and pleural effusion on the right side. Thoracocentesis yielded noncoagulating blood. Hematology revealed normal PCV and total plasma protein that decreased within 24 hours to 20% and 50 g/L (20%/5.0 g/dL), respectively. The dog was treated with IV fluids, tranexamic acid, and fresh frozen plasma. An aortic aneurysm with irregular mineralization of the right ventrolateral aortic wall was identified on computed tomography examination, which also demonstrated a peri-aortic hematoma. A decision was made to attempt treatment with a stent graft. Under general anesthesia, a marker catheter was inserted into the esophagus. A 10-Fr sheath was inserted into the right femoral artery, and an angiography catheter was advanced over a wire. After angiography, a stent graft (12-mm x 50-mm) was placed over the guide wire and deployed under fluoroscopic guidance. The dog recovered uneventfully, with no evidence of recurrent bleeding, and was discharged 2 days after the procedure with antimicrobials, anthelmintic, and antithrombotic treatment. At 90-day follow-up, the dog was doing well, and stent position was radiographically confirmed. New or unique information provided This report describes successful management of aortic aneurysm and dissection, an uncommon and challenging pathology in the veterinary practice with few available treatment options. Stent graft placement is a minimally invasive procedure in which a covered stent is placed over the lesion to prevent rupture.
引用
收藏
页码:806 / 812
页数:7
相关论文
共 50 条
  • [31] Endovascular Stent-Graft Repair of a Tuberculous Mycotic Aortic Aneurysm
    Han, Daniel K.
    Chung, Christine
    Walkup, Maggie H.
    Faries, Peter L.
    Marin, Michael L.
    Ellozy, Sharif H.
    ANNALS OF VASCULAR SURGERY, 2011, 25 (05) : 699.e13 - 699.e16
  • [32] The choice of stent-graft for endovascular repair of abdominal aortic aneurysm
    Chuter, TAM
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (04): : 519 - 525
  • [33] Stent-graft treatment of a ruptured aortic graft: a case report
    Vidal, V
    Amabile, P
    Jacquier, A
    Pascal, T
    Chapon, F
    Rollet, G
    Le Corroller, T
    Gaubert, JY
    Champsaur, P
    Moulin, G
    Piquet, P
    Bartoli, JM
    JOURNAL DE RADIOLOGIE, 2005, 86 (01): : 76 - 78
  • [34] Therapeutic Strategies for Infectious Multiple Aortic Aneurysms: Thoracoabdominal Aortic Aneurysm Treatment Using a Fenestrated Stent-Graft
    Okugi, Satoshi
    Azuma, Takashi
    Yokoi, Yoshihiko
    Domoto, Satoru
    Niinami, Hiroshi
    ANNALS OF VASCULAR DISEASES, 2020, 13 (03) : 326 - 329
  • [35] Thoracic CT findings following endovascular stent-graft treatment for thoracic aortic aneurysm
    Ishida, Masaki
    Kato, Noriyuki
    Hirano, Tadanori
    Shimono, Takatsugu
    Shimpo, Hideto
    Takeda, Kan
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (03) : 333 - 341
  • [36] Endovascular stent-graft treatment for blunt aortic injury
    Kato, M
    Yatsu, S
    Sato, H
    Kyo, S
    CIRCULATION JOURNAL, 2004, 68 (06) : 553 - 557
  • [37] Combined Stent-graft and Surgical Treatment a Thoracoabdominal Aortic Aneurysm in a High Risk Patient
    Minami, Hiroya
    Mukohara, Nobuhiko
    Obo, Hidefumi
    Yoshida, Masato
    Fukuda, Tetsuya
    Shida, Tsutomu
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2005, 53 (08) : 448 - 451
  • [38] Early and midterm outcomes of open stent-graft treatment for distal aortic arch aneurysm
    Yamada K.
    Mochizuki T.
    Tsubota H.
    Funamoto M.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (10) : 490 - 497
  • [39] Combined stent-graft and surgical treatment for a thoracoabdominal aortic aneurysm in a high risk patient
    Minami H.
    Mukohara N.
    Obo H.
    Yoshida M.
    Fukuda T.
    Shida T.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2005, 53 (8) : 448 - 451
  • [40] Efficacy of Unibody Bifurcated Endovascular Stent-Graft Repair in the Treatment of Abdominal Aortic Aneurysm
    Shi, Chaohai
    Chen, Quan
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (05): : 444 - 447