Balloon expandable aortic stent-graft for the treatment of aortic aneurysm and rupture in a dog

被引:0
|
作者
Klainbart, Sigal [1 ]
Segev, Gilad [2 ]
Chen, Hilla [2 ]
Peery, Dana [3 ]
Shipov, Anna [4 ]
机构
[1] Hebrew Univ Jerusalem, Dept Small Anim Emergency & Crit Care, Vet Teaching Hosp, Koret Sch Vet Med, POB 12, IL-761001 Rehovot, Israel
[2] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Small Anim Internal Med, Koret Sch Vet Med, Rehovot, Israel
[3] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Diagnost Imaging, Koret Sch Vet Med, Rehovot, Israel
[4] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Small Anim Surg, Koret Sch Vet Med, Rehovot, Israel
关键词
aortic dissection; endovascular stent; Spirocerca lupi; TEVAR; ENDOVASCULAR REPAIR; RATIONAL USE; DISSECTION; MANAGEMENT; ANTITHROMBOTICS; CONSENSUS; SURGERY; LUPI;
D O I
10.1111/vec.13102
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To describe the successful placement of an aortic stent graft in a dog suffering from aortic aneurysm and rupture. Case summary A 4-year-old neutered female mixed breed dog weighing 25 kg was presented with a chief complaint of acute onset of weakness and respiratory distress. On presentation, the dog was lateral and unresponsive, hypothermic, tachycardic, and tachypneic. Pleural effusion was identified in the right hemi-thorax on thoracic-focused sonographic scan for trauma. Thoracic radiographs showed a fluid/soft tissue opacity in the cranial mediastinum and pleural effusion on the right side. Thoracocentesis yielded noncoagulating blood. Hematology revealed normal PCV and total plasma protein that decreased within 24 hours to 20% and 50 g/L (20%/5.0 g/dL), respectively. The dog was treated with IV fluids, tranexamic acid, and fresh frozen plasma. An aortic aneurysm with irregular mineralization of the right ventrolateral aortic wall was identified on computed tomography examination, which also demonstrated a peri-aortic hematoma. A decision was made to attempt treatment with a stent graft. Under general anesthesia, a marker catheter was inserted into the esophagus. A 10-Fr sheath was inserted into the right femoral artery, and an angiography catheter was advanced over a wire. After angiography, a stent graft (12-mm x 50-mm) was placed over the guide wire and deployed under fluoroscopic guidance. The dog recovered uneventfully, with no evidence of recurrent bleeding, and was discharged 2 days after the procedure with antimicrobials, anthelmintic, and antithrombotic treatment. At 90-day follow-up, the dog was doing well, and stent position was radiographically confirmed. New or unique information provided This report describes successful management of aortic aneurysm and dissection, an uncommon and challenging pathology in the veterinary practice with few available treatment options. Stent graft placement is a minimally invasive procedure in which a covered stent is placed over the lesion to prevent rupture.
引用
收藏
页码:806 / 812
页数:7
相关论文
共 50 条
  • [21] Endovascular Stent-graft Placement for the Emergency Treatment of Ruptured Descending Aortic Aneurysm
    Koc, Osman
    Batur, Abdussamet
    Karabekmez, Leman Gunbey
    Gormus, Niyazi
    Cil, Barbaros
    Vural, Alaattin
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2014, 13 (02) : 97 - 98
  • [22] Balloon-Supported Passage of a Stent-Graft into the Aortic Arch
    Eun, Na Lae
    Lee, Dahye
    Song, Suk-Won
    Joo, Seung-Moon
    Koelbel, Tilo
    Lee, Kwang-Hun
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (04) : 744 - 748
  • [23] Aortic aneurysms' treatment with endovascular stent-graft
    Rahman, Ali
    Colak, Mehmet Cengiz
    Ozdemir, Huseyin
    Ozguler, Murat
    Cil, Barbaros E.
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 17 (03): : 167 - 172
  • [24] In Vitro Evaluation of the Gore Viabahn Balloon-Expandable Stent-Graft for Fenestrated Endovascular Aortic Repair
    Torsello, Giovanni Federico
    Herten, Monika
    Mueller, Markus
    Andre-Frank
    Torsello, Giovanni B.
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (03) : 361 - 368
  • [25] Endoluminal stent-graft treatment for distal aortic arch aneurysm: A special challenge
    Dake, MD
    Semba, CP
    Kee, ST
    Kato, N
    Mitchell, RS
    Miller, DC
    RADIOLOGY, 1996, 201 : 629 - 629
  • [26] Abdominal aortic aneurysm treatment: Preliminary results with the talent stent-graft system
    Uflacker, R
    Robison, JG
    Brothers, TE
    Pereira, AH
    Sanvitto, PC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) : 51 - 60
  • [27] Stent-graft repair of an aortic rupture caused by invasive hemangiopericytoma
    van der Starre, Pieter J. A.
    Sze, Daniel Y.
    Guta, Cosmin
    Mitchell, R. Scott
    Dake, Michael D.
    ANNALS OF THORACIC SURGERY, 2006, 81 (06): : 2300 - 2302
  • [28] Acute traumatic aortic rupture:: early stent-graft repair
    Lachat, M
    Pfammatter, T
    Witzke, H
    Bernard, E
    Wolfensberger, U
    Künzli, A
    Turina, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (06) : 959 - 963
  • [29] Stent-graft repair for acute traumatic thoracic aortic rupture
    Neuhauser, B
    Czermak, B
    Jaschke, W
    Waldenberger, P
    Fraedrich, G
    Perkmann, R
    AMERICAN SURGEON, 2004, 70 (12) : 1039 - 1044
  • [30] Separation of the Modular Stent-Graft Within the Abdominal Aortic Aneurysm
    Tsao, Nai-Wen
    Shih, Chun-Ming
    Lin, Feng-Yen
    Shao, Wen-Tein
    Lee, Chi-Ming
    Ou, Keng-Liang
    Chang, Nein-Chun
    Huang, Chun-Yao
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (12) : E199 - E199