Balloon expandable aortic stent-graft for the treatment of aortic aneurysm and rupture in a dog

被引:0
|
作者
Klainbart, Sigal [1 ]
Segev, Gilad [2 ]
Chen, Hilla [2 ]
Peery, Dana [3 ]
Shipov, Anna [4 ]
机构
[1] Hebrew Univ Jerusalem, Dept Small Anim Emergency & Crit Care, Vet Teaching Hosp, Koret Sch Vet Med, POB 12, IL-761001 Rehovot, Israel
[2] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Small Anim Internal Med, Koret Sch Vet Med, Rehovot, Israel
[3] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Diagnost Imaging, Koret Sch Vet Med, Rehovot, Israel
[4] Hebrew Univ Jerusalem, Vet Teaching Hosp, Dept Small Anim Surg, Koret Sch Vet Med, Rehovot, Israel
关键词
aortic dissection; endovascular stent; Spirocerca lupi; TEVAR; ENDOVASCULAR REPAIR; RATIONAL USE; DISSECTION; MANAGEMENT; ANTITHROMBOTICS; CONSENSUS; SURGERY; LUPI;
D O I
10.1111/vec.13102
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To describe the successful placement of an aortic stent graft in a dog suffering from aortic aneurysm and rupture. Case summary A 4-year-old neutered female mixed breed dog weighing 25 kg was presented with a chief complaint of acute onset of weakness and respiratory distress. On presentation, the dog was lateral and unresponsive, hypothermic, tachycardic, and tachypneic. Pleural effusion was identified in the right hemi-thorax on thoracic-focused sonographic scan for trauma. Thoracic radiographs showed a fluid/soft tissue opacity in the cranial mediastinum and pleural effusion on the right side. Thoracocentesis yielded noncoagulating blood. Hematology revealed normal PCV and total plasma protein that decreased within 24 hours to 20% and 50 g/L (20%/5.0 g/dL), respectively. The dog was treated with IV fluids, tranexamic acid, and fresh frozen plasma. An aortic aneurysm with irregular mineralization of the right ventrolateral aortic wall was identified on computed tomography examination, which also demonstrated a peri-aortic hematoma. A decision was made to attempt treatment with a stent graft. Under general anesthesia, a marker catheter was inserted into the esophagus. A 10-Fr sheath was inserted into the right femoral artery, and an angiography catheter was advanced over a wire. After angiography, a stent graft (12-mm x 50-mm) was placed over the guide wire and deployed under fluoroscopic guidance. The dog recovered uneventfully, with no evidence of recurrent bleeding, and was discharged 2 days after the procedure with antimicrobials, anthelmintic, and antithrombotic treatment. At 90-day follow-up, the dog was doing well, and stent position was radiographically confirmed. New or unique information provided This report describes successful management of aortic aneurysm and dissection, an uncommon and challenging pathology in the veterinary practice with few available treatment options. Stent graft placement is a minimally invasive procedure in which a covered stent is placed over the lesion to prevent rupture.
引用
收藏
页码:806 / 812
页数:7
相关论文
共 50 条
  • [1] Balloon-Expandable Aortic Stent-Graft for Treatment of Descending Aortic Rupture Presumably Secondary to Spiroserca lupi Larvae Migration
    Avner, A.
    Willenz, U.
    Sabbag, I
    Moreshet, A.
    Bruckheimer, E.
    ISRAEL JOURNAL OF VETERINARY MEDICINE, 2016, 71 (03): : 43 - 47
  • [2] Acute rupture of an aortic false aneurysm treated with a stent-graft
    Schönholz, C
    Donnini, F
    Naselli, G
    Pocovi, A
    Parodi, JC
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (03): : 293 - 296
  • [3] Endovascular stent-graft prosthesis of aortic aneurysm
    Ince, H
    Nienaber, CA
    ZEITSCHRIFT FUR KARDIOLOGIE, 2001, 90 (01): : 67 - 72
  • [4] Combined approach to stent-graft treatment of an aortic arch aneurysm
    Buth, J
    Penn, O
    Tielbeek, A
    Mersman, M
    JOURNAL OF ENDOVASCULAR SURGERY, 1998, 5 (04): : 329 - 332
  • [5] Stent-graft repair for abdominal aortic aneurysm
    Kalman, PG
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1999, 161 (09) : 1133 - 1133
  • [6] Intraoperative rupture of an abdominal aortic aneurysm during an endovascular stent-graft procedure
    David M. Moskowitz
    Ronald A. Kahn
    Michael L. Marin
    Larry H. Hollier
    Canadian Journal of Anesthesia, 1999, 46 : 887 - 890
  • [7] Intraoperative rupture of an abdominal aortic aneurysm during an endovascular stent-graft procedure
    Moskowitz, DM
    Kahn, RA
    Marin, ML
    Hollier, LH
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (09): : 887 - 890
  • [8] Aneurysm volume and diameter change following stent-graft treatment of aortic aneurysm
    Rubin, GD
    Stucker, DT
    Dake, MD
    Semba, CP
    Napel, SA
    RADIOLOGY, 1997, 205 : 71 - 71
  • [9] Elective stent-graft treatment of aortic
    Lee, KH
    Won, JY
    Lee, DY
    Choi, D
    Shim, WH
    Chang, BC
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (06) : 667 - 675
  • [10] Stent-graft deployment for aortic rupture after stenting for aortic recoarctation
    Alcibar, Juan
    Pena, Natividad
    Inguanzo, Ramon
    Arriola, M. Jesus
    Garcia, Koldobika
    Eguia, Ibon
    Sainz, Inigo
    Barrenetxea, Jose I.
    TEXAS HEART INSTITUTE JOURNAL, 2007, 34 (04) : 453 - 456