Numerical assessment of the methods of measurement of the electrical resistance in carbon fiber reinforced cement

被引:22
|
作者
Zhu, Sirong [1 ]
Chung, D. D. L. [1 ]
机构
[1] SUNY Buffalo, Composite Mat Res Lab, Buffalo, NY 14260 USA
来源
SMART MATERIALS & STRUCTURES | 2007年 / 16卷 / 04期
关键词
CONDUCTIVE CONCRETE; STRAIN; COMPRESSION; COMPOSITES; MORTAR; DAMAGE;
D O I
10.1088/0964-1726/16/4/026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Carbon fiber reinforced cement is a smart material due to its sensing ability, which is based on piezoresistivity. A finite element model for simulating the measurement of electrical resistance in this material is provided. The measured four-probe resistance decreases with increasing distance between the adjacent voltage and current contacts. For a beam of size 320 x 40 x 40 mm(3), the minimum distance for accurate four-probe resistivity measurement is 5 mm for surface contacts (at the end surfaces), 5 mm for loop contacts (around the perimeter) and 40 mm for line contacts (on one surface). The two-probe resistivity is most inaccurate for the line contacts. For loop contacts, the two-probe resistivity is accurate when the aspect ratio exceeds 8, and the four-probe resistivity is accurate when the aspect ratio exceeds 1.5. For a column of size 426 x 92 x 76 mm(3), the minimum distance between the adjacent current and voltage contacts for accurate four-probe resistivity measurement is 50 mm for loop contacts and 400 mm for line contacts. For a slab of size 9.75 x 4.88 x 0.30 m(3), the minimum distance for accurate four-probe resistivity measurement along the 9.75 m length is 250 mm for line contacts.
引用
收藏
页码:1164 / 1170
页数:7
相关论文
共 50 条
  • [21] Electrical conductivity characterization and variation of carbon fiber reinforced cement composite
    Wang, XF
    Wang, YL
    Jin, ZH
    JOURNAL OF MATERIALS SCIENCE, 2002, 37 (01) : 223 - 227
  • [22] Statistical analysis for divergence of specific resistance of carbon fiber reinforced cement
    Guan, X. C.
    Han, B. G.
    Ou, J. P.
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2006, : 1489 - 1493
  • [23] Uniaxial compression in carbon fiber-reinforced cement, sensed by electrical resistivity measurement in longitudinal and transverse directions
    Wen, SH
    Chung, DDL
    CEMENT AND CONCRETE RESEARCH, 2001, 31 (02) : 297 - 301
  • [24] Temperature and humidity variation of specific resistance of carbon fiber reinforced cement
    Guan, XC
    Han, BG
    Tang, MH
    Ou, JP
    SMART STRUCTURES AND MATERIALS 2005: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE, PTS 1 AND 2, 2005, 5765 : 1 - 7
  • [25] Electrical-resistance-based Sensing of Impact Damage in Carbon Fiber Reinforced Cement-based Materials
    Meehan, David G.
    Wang, Shoukai
    Chung, D. D. L.
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2010, 21 (01) : 83 - 105
  • [26] Review on the Electrical Resistance/Conductivity of Carbon Fiber Reinforced Polymer
    Zhao, Qian
    Zhang, Kai
    Zhu, Shuang
    Xu, Hanyang
    Cao, Dianguo
    Zhao, Lina
    Zhang, Ronghua
    Yin, Wuliang
    APPLIED SCIENCES-BASEL, 2019, 9 (11):
  • [27] Electrical resistance - compressive strain relationship of steel fiber reinforced cement composites
    Teomete, Egemen
    Kocyigit, Ozgun Ilkim
    CEMENT WAPNO BETON, 2015, 20 (04): : 244 - +
  • [28] The role of electronic and ionic conduction in the electrical conductivity of carbon fiber reinforced cement
    Wen, Sihai
    Chung, D. D. L.
    CARBON, 2006, 44 (11) : 2130 - 2138
  • [29] Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement
    Kang, Ji Ho
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2009, 29 (04) : 323 - 330
  • [30] Interfacial and wetting properties of carbon fiber reinforced epoxy composites with different hardeners by electrical resistance measurement
    Kwon, Dong-Jun
    Shin, Pyeong-Su
    Kim, Jong-Hyun
    DeVries, K. Lawrence
    Park, Joung-Man
    POLYMER TESTING, 2016, 53 : 293 - 298