Numerical assessment of the methods of measurement of the electrical resistance in carbon fiber reinforced cement

被引:22
|
作者
Zhu, Sirong [1 ]
Chung, D. D. L. [1 ]
机构
[1] SUNY Buffalo, Composite Mat Res Lab, Buffalo, NY 14260 USA
来源
SMART MATERIALS & STRUCTURES | 2007年 / 16卷 / 04期
关键词
CONDUCTIVE CONCRETE; STRAIN; COMPRESSION; COMPOSITES; MORTAR; DAMAGE;
D O I
10.1088/0964-1726/16/4/026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Carbon fiber reinforced cement is a smart material due to its sensing ability, which is based on piezoresistivity. A finite element model for simulating the measurement of electrical resistance in this material is provided. The measured four-probe resistance decreases with increasing distance between the adjacent voltage and current contacts. For a beam of size 320 x 40 x 40 mm(3), the minimum distance for accurate four-probe resistivity measurement is 5 mm for surface contacts (at the end surfaces), 5 mm for loop contacts (around the perimeter) and 40 mm for line contacts (on one surface). The two-probe resistivity is most inaccurate for the line contacts. For loop contacts, the two-probe resistivity is accurate when the aspect ratio exceeds 8, and the four-probe resistivity is accurate when the aspect ratio exceeds 1.5. For a column of size 426 x 92 x 76 mm(3), the minimum distance between the adjacent current and voltage contacts for accurate four-probe resistivity measurement is 50 mm for loop contacts and 400 mm for line contacts. For a slab of size 9.75 x 4.88 x 0.30 m(3), the minimum distance for accurate four-probe resistivity measurement along the 9.75 m length is 250 mm for line contacts.
引用
收藏
页码:1164 / 1170
页数:7
相关论文
共 50 条
  • [11] Electrical resistance properties of Cement/carbon fiber composite
    Dong, Biqin
    Xing, Feng
    Cui, Hongzhi
    Li, Zongjin
    MATERIAL SCIENCES AND TECHNOLOGY, PTS 1 & 2, 2012, 560-561 : 830 - 836
  • [12] Biaxial compression in carbon-fiber-reinforced mortar, sensed by electrical resistance measurement
    Wu, B
    Huang, XJ
    Lu, JZ
    CEMENT AND CONCRETE RESEARCH, 2005, 35 (07) : 1430 - 1434
  • [13] Damage detection of carbon fiber reinforced polymer composites via electrical resistance measurement
    Wen, Jie
    Xia, Zhenhai
    Choy, Fred
    COMPOSITES PART B-ENGINEERING, 2011, 42 (01) : 77 - 86
  • [14] Biaxial compression in carbon fiber-reinforced mortar sensed by electrical resistance measurement
    Wu, B
    Huang, XJ
    Lu, JZ
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 893 - 898
  • [15] Damage assessment through electrical resistance measurement in graphite fiber-reinforced composites
    Prabhakaran, R.
    Experimental Techniques, 1990, 14 (01) : 16 - 20
  • [16] Calculation model of resistance for carbon fiber reinforced cement composite
    Yao, Wu
    Zhong, Wenhui
    Kuei Suan Jen Hsueh Pao/ Journal of the Chinese Ceramic Society, 2007, 35 (07): : 893 - 898
  • [17] Uniaxial tension in carbon fiber reinforced cement, sensed by electrical resistivity measurement in longitudinal and transverse directions
    Wen, SH
    Chung, DDL
    CEMENT AND CONCRETE RESEARCH, 2000, 30 (08) : 1289 - 1294
  • [18] Electrical conductivity characterization and variation of carbon fiber reinforced cement composite
    Xiufeng Wang
    Yonglan Wang
    Zhihao Jin
    Journal of Materials Science, 2002, 37 : 223 - 227
  • [19] Research on Optimizing the Electrical and Mechanical Properties of Carbon Fiber Reinforced Cement
    Xu, Jing
    Yao, Wu
    TESTING AND EVALUATION OF ADVANCED BUILDING MATERIALS, 2013, 539 : 94 - 98
  • [20] Study on Electrical Properties of Carbon Fiber Reinforced Cement Paste with CCCW
    Fan Xiaoming
    Dong Xu
    Sun Mingqing
    Li Zhuoqiu
    ADVANCED SYNTHESIS AND PROCESSING TECHNOLOGY FOR MATERIALS, 2009, 66 : 273 - +