Numerical assessment of the methods of measurement of the electrical resistance in carbon fiber reinforced cement

被引:22
|
作者
Zhu, Sirong [1 ]
Chung, D. D. L. [1 ]
机构
[1] SUNY Buffalo, Composite Mat Res Lab, Buffalo, NY 14260 USA
来源
SMART MATERIALS & STRUCTURES | 2007年 / 16卷 / 04期
关键词
CONDUCTIVE CONCRETE; STRAIN; COMPRESSION; COMPOSITES; MORTAR; DAMAGE;
D O I
10.1088/0964-1726/16/4/026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Carbon fiber reinforced cement is a smart material due to its sensing ability, which is based on piezoresistivity. A finite element model for simulating the measurement of electrical resistance in this material is provided. The measured four-probe resistance decreases with increasing distance between the adjacent voltage and current contacts. For a beam of size 320 x 40 x 40 mm(3), the minimum distance for accurate four-probe resistivity measurement is 5 mm for surface contacts (at the end surfaces), 5 mm for loop contacts (around the perimeter) and 40 mm for line contacts (on one surface). The two-probe resistivity is most inaccurate for the line contacts. For loop contacts, the two-probe resistivity is accurate when the aspect ratio exceeds 8, and the four-probe resistivity is accurate when the aspect ratio exceeds 1.5. For a column of size 426 x 92 x 76 mm(3), the minimum distance between the adjacent current and voltage contacts for accurate four-probe resistivity measurement is 50 mm for loop contacts and 400 mm for line contacts. For a slab of size 9.75 x 4.88 x 0.30 m(3), the minimum distance for accurate four-probe resistivity measurement along the 9.75 m length is 250 mm for line contacts.
引用
收藏
页码:1164 / 1170
页数:7
相关论文
共 50 条
  • [1] Electrical resistance of carbon fiber reinforced cement composite
    Dong, Bi-Qin
    Yin, Hui
    Xing, Feng
    Li, Zong-Jin
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2007, 10 (05): : 538 - 542
  • [2] Assessment of the damage in carbon fiber reinforced concrete by acoustic emission and resistance measurement methods
    Zhao Jiao
    Xu Zhihong
    ENGINEERING STRUCTURAL INTEGRITY: RESEARCH, DEVELOPMENT AND APPLICATION, VOLS 1 AND 2, 2007, : 1493 - 1496
  • [3] Electrical resistance and microstructure of latex modified carbon fiber reinforced cement composites
    Wei Jian
    Cheng Feng
    Yuan Hudie
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2012, 27 (04): : 746 - 749
  • [4] Electrical resistance stability of high content carbon fiber reinforced cement composite
    杨再富
    Journal of Chongqing University, 2005, (01) : 19 - 22
  • [5] Electrical resistance and microstructure of latex modified carbon fiber reinforced cement composites
    Jian Wei
    Feng Cheng
    Hudie Yuan
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2012, 27 : 746 - 749
  • [6] Electrical resistance measurement on carbon fiber reinforced thermoplastics with rivets as electrodes
    De Baere, I.
    Van Paepegem, W.
    Degrieck, J.
    EMERGING TECHNOLOGIES IN NON-DESTRUCTIVE TESTING, 2008, : 269 - 274
  • [7] Correlation between compressive strain and electrical resistance in carbon fiber reinforced cement composites
    Teomete, Egemen
    Kocyigit, Ozgun Ilkim
    CEMENT WAPNO BETON, 2015, 20 (01): : 1 - +
  • [8] Effect of carbon fiber grade on the electrical behavior of carbon fiber reinforced cement
    Wen, SH
    Chung, DDL
    CARBON, 2001, 39 (03) : 369 - 373
  • [9] Damage in carbon fiber-reinforced concrete, monitored by electrical resistance measurement
    Bontea, DM
    Chung, DDL
    Lee, GC
    CEMENT AND CONCRETE RESEARCH, 2000, 30 (04) : 651 - 659
  • [10] Electrical-resistance-based damage self-sensing in carbon fiber reinforced cement
    Wen, Sihai
    Chung, D. D. L.
    CARBON, 2007, 45 (04) : 710 - 716