Microscopic examination of the sonothrombolysis process inside the transparent to ultrasound parallel plate flow chamber

被引:0
|
作者
Secomski, Wojciech [1 ]
Klimonda, Ziemowit [1 ]
Majka, Katarzyna [2 ]
Olszewski, Robert [1 ,3 ]
Nowicki, Andrzej [1 ]
机构
[1] Polish Acad Sci, Dept Ultrasound, Inst Fundamental Technol Res, Warsaw, Poland
[2] Med Univ Warsaw, Clin Traumatol & Orthoped, Mil Inst Med Warsaw, Dept Basic Nursing, Warsaw, Poland
[3] Polish Acad Sci, Dept Gerontol, Publ Hlth & Didact, Natl Inst Geriatr Rheumatol & Rehabil, Warsaw, Poland
关键词
ultrasound; blood; thrombus; thrombolysis; parallel plate flow chamber;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parallel plate flow chambers are widely used for cell research in conditions of constant or pulsatile liquid flow. They are also used to analyze the formation of thrombi. The authors designed a flow chamber that is transparent to ultrasound, thus enabling the microscopic observation of the thrombus dissolution process by interaction of drug, microbubbles and ultrasound in real time, in-vitro. Sonothrombolysis was performed at 1 MHz and 3.3 MHz ultrasound frequencies, at space-averaged and time-averaged intensities I-SATA of 0.2 - 1.6 W/cm(2).1 mm thick slices of the human blood clots were exposed to ultrasound in the presence of the Actilyse tissue plasminogen activator at a concentration of 10 mu g/ml flowing around the sample. Next, the effect of SonoVue microbubbles at a concentration of 5x10(5)/ml on the dissolution of the thrombus was investigated. Thrombus size changes were observed under a 4x magnification microscope and were recorded as a function of time. The best result was achieved for the Actilyse tissue plasminogen activator at the 1 MHz and 1.6/cm(2) I-SATA, the thrombus was sonolysed within 5.5 minutes. The noticeable effect of the SonoVue microbubbles on the thrombolysis process appeared at 3.3 MHz, the thrombus was sonolysed in 12 min at I-SATA = 1.6 W/cm(2).
引用
收藏
页数:4
相关论文
共 50 条
  • [21] In vitro Parallel Plate Flow Chamber Assessment of Endothelial Progenitor Cell Homing
    Barnett, J. M.
    Toma, H. S.
    McCollum, G. W.
    Penn, J. S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [22] Analysis of Pulsatile Flow in the Parallel-Plate Flow Chamber with Spatial Shear Stress Gradient
    Kai-rong Qin
    Xu-qu Hu
    Zhao-rong Liu
    Journal of Hydrodynamics, 2007, 19 : 113 - 120
  • [23] A Modified Parallel Plate Flow Chamber to Study Local Endothelial Response to Recirculating Disturbed Flow
    Sedlak, Jason Matthew
    Clyne, Alisa Morss
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (04):
  • [24] ANALYSIS OF PULSATILE FLOW IN THE PARALLEL-PLATE FLOW CHAMBER WITH SPATIAL SHEAR STRESS GRADIENT
    Qin Kai-rong
    Hu Xu-qu
    Liu Zhao-rong
    JOURNAL OF HYDRODYNAMICS, 2007, 19 (01) : 113 - 120
  • [26] Non-uniform flow behavior in a parallel plate flow chamber alters endothelial cell responses
    McCann, JA
    Peterson, SD
    Plesniak, MW
    Webster, TJ
    Haberstroh, KM
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (03) : 328 - 336
  • [27] Non-Uniform Flow Behavior in a Parallel Plate Flow Chamber Alters Endothelial Cell Responses
    Jennifer A. McCann
    Sean D. Peterson
    Michael W. Plesniak
    Thomas J. Webster
    Karen M. Haberstroh
    Annals of Biomedical Engineering, 2005, 33
  • [28] Parallel-plate flow chamber for studies of 3D flow-endothelium interaction
    Watkins, NV
    Caro, CG
    Wang, W
    BIORHEOLOGY, 2002, 39 (3-4) : 337 - 342
  • [29] Pooled human immunoglobulins reduce adhesion of Pseudomonas aeruginosa in a parallel plate flow chamber
    Poelstra, KA
    van der Mei, HC
    Gottenbos, B
    Grainger, DW
    van Horn, JR
    Busscher, HJ
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 51 (02): : 224 - 232
  • [30] Measuring the elasticity of HL-60 cell microvillus by parallel plate flow chamber
    Huang, Qiang
    Ling, Ying-Chen
    Li, Qu-Huan
    Wu, Jian-Hua
    Fang, Ying
    Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 2010, 25 (04): : 277 - 282