A Modified Parallel Plate Flow Chamber to Study Local Endothelial Response to Recirculating Disturbed Flow

被引:6
|
作者
Sedlak, Jason Matthew [1 ]
Clyne, Alisa Morss [2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, 3141 Chestnut St, Philadelphia, PA 19104 USA
[2] Drexel Univ, Dept Mech Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
关键词
FLUID SHEAR-STRESS; IN-VITRO MODEL; NITRIC-OXIDE; VE-CADHERIN; CELLS; ADHESION; EXPRESSION; REORGANIZATION; PERMEABILITY; STIMULATION;
D O I
10.1115/1.4044899
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atherosclerosis develops at arterial sites where endothelial cells (ECs) are exposed to low time-averaged shear stress, in particular in regions of recirculating disturbed flow. To understand how hemodynamics contributes to EC dysfunction in atheroma development, an in vitro parallel plate flow chamber gasket was modified with protruding baffles to produce large recirculating flow regions. Computational fluid dynamics (CFD) predicted that more than 60% of the flow surface area was below the 12 dynes/cm(2) atheroprotective threshold. Bovine aortic endothelial cells (BAECs) were then seeded in the parallel plate flow chamber with either the standard laminar or the new disturbed flow gasket (DFG) and exposed to flow for 36h. Cell morphology, nitric oxide (NO), proliferation, permeability, and monocyte adhesion were assessed by phase contrast and confocal microscopy. BAEC exposed to 20 dynes/cm(2) shear stress in the laminar flow device aligned and elongated in the flow direction while increasing nitric oxide, decreasing permeability, and maintaining low proliferation and monocyte adhesion. BAEC in the recirculating flow and low shear stress disturbed flow device regions did not elongate or align, produced less nitric oxide, and showed higher proliferation, permeability, and monocyte adhesion than cells in the laminar flow device. However, cells in disturbed flow device regions exposed to atheroprotective shear stress did not consistently align or decrease permeability, and these cells demonstrated low nitric oxide levels. The new parallel plate DFG provides a means to study recirculating flow, highlighting the complex relationship between hemodynamics and endothelial function.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] The numerical design of a parallel plate flow chamber for investigation of endothelial cell response to shear stress
    Chung, BJ
    Robertson, AM
    Peters, DG
    COMPUTERS & STRUCTURES, 2003, 81 (8-11) : 535 - 546
  • [2] VASCULAR ENDOTHELIAL RESPONSE TO DISTURBED FLOW
    CHIU, JJ
    WUNG, SL
    CHANG, CH
    USAMI, S
    FASEB JOURNAL, 1995, 9 (03): : A322 - A322
  • [3] In vitro Parallel Plate Flow Chamber Assessment of Endothelial Progenitor Cell Homing
    Barnett, J. M.
    Toma, H. S.
    McCollum, G. W.
    Penn, J. S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Non-uniform flow behavior in a parallel plate flow chamber alters endothelial cell responses
    McCann, JA
    Peterson, SD
    Plesniak, MW
    Webster, TJ
    Haberstroh, KM
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (03) : 328 - 336
  • [5] Non-Uniform Flow Behavior in a Parallel Plate Flow Chamber Alters Endothelial Cell Responses
    Jennifer A. McCann
    Sean D. Peterson
    Michael W. Plesniak
    Thomas J. Webster
    Karen M. Haberstroh
    Annals of Biomedical Engineering, 2005, 33
  • [6] Drug Adhesion Parallel Plate Flow Chamber
    Han, G.
    Hardiman, K.
    Hyer, R.
    2012 38TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2012, : 145 - 146
  • [7] On analysis of the steady flow in an irrectangular parallel-plate flow chamber
    Kairong Q.
    Weiyuan J.
    Xixi L.
    Zhaorong L.
    Applied Mathematics and Mechanics, 1998, 19 (9) : 851 - 859
  • [8] On analysis of the steady flow in an irrectangular parallel-plate flow chamber
    Qin, KR
    Jiang, WY
    Li, XX
    Liu, ZR
    APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 1998, 19 (09) : 851 - 859
  • [9] On analysis of the steady flow in an irrectangular parallel-plate flow chamber
    Fudan Univ, Shanghai, China
    Appl Math Mech Engl Ed, 9 (851-859):
  • [10] Parallel-plate Flow Chamber and Continuous Flow Circuit to Evaluate Endothelial Progenitor Cells under Laminar Flow Shear Stress
    Lane, Whitney O.
    Jantzen, Alexandra E.
    Carlon, Tim A.
    Jamiolkowski, Ryan M.
    Grenet, Justin E.
    Ley, Melissa M.
    Haseltine, Justin M.
    Galinat, Lauren J.
    Lin, Fu-Hsiung
    Allen, Jason D.
    Truskey, George A.
    Achneck, Hardean E.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (59):