A Modified Parallel Plate Flow Chamber to Study Local Endothelial Response to Recirculating Disturbed Flow

被引:6
|
作者
Sedlak, Jason Matthew [1 ]
Clyne, Alisa Morss [2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, 3141 Chestnut St, Philadelphia, PA 19104 USA
[2] Drexel Univ, Dept Mech Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
关键词
FLUID SHEAR-STRESS; IN-VITRO MODEL; NITRIC-OXIDE; VE-CADHERIN; CELLS; ADHESION; EXPRESSION; REORGANIZATION; PERMEABILITY; STIMULATION;
D O I
10.1115/1.4044899
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Atherosclerosis develops at arterial sites where endothelial cells (ECs) are exposed to low time-averaged shear stress, in particular in regions of recirculating disturbed flow. To understand how hemodynamics contributes to EC dysfunction in atheroma development, an in vitro parallel plate flow chamber gasket was modified with protruding baffles to produce large recirculating flow regions. Computational fluid dynamics (CFD) predicted that more than 60% of the flow surface area was below the 12 dynes/cm(2) atheroprotective threshold. Bovine aortic endothelial cells (BAECs) were then seeded in the parallel plate flow chamber with either the standard laminar or the new disturbed flow gasket (DFG) and exposed to flow for 36h. Cell morphology, nitric oxide (NO), proliferation, permeability, and monocyte adhesion were assessed by phase contrast and confocal microscopy. BAEC exposed to 20 dynes/cm(2) shear stress in the laminar flow device aligned and elongated in the flow direction while increasing nitric oxide, decreasing permeability, and maintaining low proliferation and monocyte adhesion. BAEC in the recirculating flow and low shear stress disturbed flow device regions did not elongate or align, produced less nitric oxide, and showed higher proliferation, permeability, and monocyte adhesion than cells in the laminar flow device. However, cells in disturbed flow device regions exposed to atheroprotective shear stress did not consistently align or decrease permeability, and these cells demonstrated low nitric oxide levels. The new parallel plate DFG provides a means to study recirculating flow, highlighting the complex relationship between hemodynamics and endothelial function.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Response of human endothelial cells to the vortex flow in an immediately expanding flow chamber
    Kanno K.
    Akabane H.
    Shimogonya Y.
    Kataoka N.
    Journal of Biomechanical Science and Engineering, 2022, 17 (03):
  • [22] An innovative parallel plate flow chamber system for studying cell behavior under pulsatile flow
    Fan, YB
    Li, JC
    Zou, YW
    Jiang, WT
    Li, XN
    Bai, L
    Chen, JK
    RECENT ADVANCES IN FLUID MECHANICS, 2004, : 663 - 666
  • [23] Analysis of Pulsatile Flow in the Parallel-Plate Flow Chamber with Spatial Shear Stress Gradient
    Kai-rong Qin
    Xu-qu Hu
    Zhao-rong Liu
    Journal of Hydrodynamics, 2007, 19 : 113 - 120
  • [24] ANALYSIS OF PULSATILE FLOW IN THE PARALLEL-PLATE FLOW CHAMBER WITH SPATIAL SHEAR STRESS GRADIENT
    Qin Kai-rong
    Hu Xu-qu
    Liu Zhao-rong
    JOURNAL OF HYDRODYNAMICS, 2007, 19 (01) : 113 - 120
  • [26] Modeling of Shear Stress Experienced by Endothelial Cells Cultured on Microstructured Polymer Substrates in a Parallel Plate Flow Chamber
    Brown, Alan
    Burke, George
    Meenan, Brian J.
    BIOTECHNOLOGY AND BIOENGINEERING, 2011, 108 (05) : 1148 - 1158
  • [27] Investigation of cell aggregation on the substrate of a parallel-plate flow chamber
    Bai, F.
    Dong, C.
    Cao, C.
    Sun, R.
    CELLULAR AND MOLECULAR BIOLOGY, 2015, 61 (02) : 86 - 93
  • [28] A novel double-layer parallel-plate flow chamber
    Lee, Won Hee
    Kang, Sungkwon
    Hirani, Anjali A.
    Lee, Yong Woo
    2007 IEEE 33RD ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2007, : 309 - 310
  • [29] Comparison of particle deposition in a parallel plate and a stagnation point flow chamber
    Yang, JL
    Bos, R
    Poortinga, A
    Wit, PJ
    Belder, GF
    Busscher, HJ
    LANGMUIR, 1999, 15 (13) : 4671 - 4677
  • [30] Blood volume is significantly reduced in a novel parallel plate flow chamber
    O'Brien, S.
    Kent, N.
    Ricco, A. J.
    Kenny, D.
    Meade, G.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 949 - 949