Deep tissue penetration of nanoparticles using pulsed-high intensity focused ultrasound

被引:14
|
作者
You, Dong Gil [1 ,2 ]
Yoon, Hong Yeol [2 ]
Jeon, Sangmin [1 ,2 ]
Um, Wooram [1 ,2 ]
Son, Sejin [2 ]
Park, Jae Hyung [1 ]
Kwon, Ick Chan [2 ,3 ]
Kim, Kwangmeyung [2 ,3 ]
机构
[1] Sungkyunkwan Univ, Sch Chem Engn, 2066 Seobu Ro, Suwon 16419, South Korea
[2] Korea Inst Sci & Technol, Biomed Res Inst, Ctr Theragnosi s, 5,Hwarang Ro 14 Gil, Seoul 02792, South Korea
[3] Korea Univ, KU KIST Grad Sch Converging Sci & Technol, 145 Anam Ro, Seoul 02841, South Korea
来源
NANO CONVERGENCE | 2017年 / 4卷
关键词
Pulsed-high intensity focused ultrasound; Tissue penetration; Nanoparticle; Drug delivery;
D O I
10.1186/s40580-017-0124-z
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Recently, ultrasound (US)-based drug delivery strategies have received attention to improve enhanced permeation and retention (EPR) effect-based passive targeting efficiency of nanoparticles in vitro and in vivo conditions. Among the US treatment techniques, pulsed-high intensity focused ultrasound (pHIFU) have specialized for improving tissue penetration of various macromolecules and nanoparticles without irreversible tissue damages. In this study, we have demonstrated that pHIFU could be utilized to improve tissue penetration of fluorescent dye-labeled glycol chitosan nanoparticles (FCNPs) in femoral tissue of mice. pHIFU could improve blood flow of the targeted-blood vessel in femoral tissue. In addition, tissue penetration of FCNPs was specifically increased 5.7-, 8- and 9.3-folds than that of non-treated (0W pHIFU) femoral tissue, when the femoral tissue was treated with 10, 20 and 50W of pHIFU, respectively. However, tissue penetration of FCNPs was significantly reduced after 3 h post-pHIFU treatment (50W). Because overdose (50W) of pHIFU led to irreversible tissue damages, including the edema and chapped red blood cells. These overall results support that pHIFU treatment can enhance the extravasation and tissue penetration of FCNPs as well as induce irreversible tissue damages. We expect that our results can provide advantages to optimize pHIFU-mediated delivery strategy of nanoparticles for further clinical applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Tissue ablation using an acoustic waveguide for high-intensity focused ultrasound
    Sommer, FG
    Sumanaweera, TS
    Glover, G
    MEDICAL PHYSICS, 1997, 24 (04) : 537 - 538
  • [22] Hemostasis using high intensity focused ultrasound
    Vaezy, Shahram
    Martin, Roy
    Mourad, Pierre
    Crum, Lawrence
    European Journal of Ultrasound, 1999, 9 (01): : 79 - 87
  • [23] Thrombolysis using high intensity focused ultrasound
    Fujikura, K
    Otsuka, R
    Abe, Y
    Kettering, JA
    Lizzi, FL
    Homma, S
    CIRCULATION, 2004, 110 (17) : 716 - 716
  • [24] HIGH-INTENSITY FOCUSED ULTRASOUND IN THE TREATMENT OF PROSTATIC TISSUE
    BIHRLE, R
    FOSTER, RS
    SANGHVI, NT
    FRY, FJ
    DONOHUE, JP
    UROLOGY, 1994, 43 (02) : 21 - 26
  • [25] Nonlinear absorption in biological tissue for high intensity focused ultrasound
    Liu, Xiaozhou
    Li, Junlun
    Gong, Xiufen
    Zhang, Dong
    ULTRASONICS, 2006, 44 : E27 - E30
  • [26] LOCALIZED TISSUE DESTRUCTION BY HIGH-INTENSITY FOCUSED ULTRASOUND
    LINKE, CA
    CARSTENSEN, EL
    FRIZZELL, LA
    ELBADAWI, A
    FRIDD, CW
    ARCHIVES OF SURGERY, 1973, 107 (06) : 887 - 891
  • [27] Delivery of Antibacterial Nanoparticles into Dentinal Tubules Using High-intensity Focused Ultrasound
    Shrestha, Annie
    Fong, Siew-Wan
    Khoo, Boo-Cheong
    Kishen, Anil
    JOURNAL OF ENDODONTICS, 2009, 35 (07) : 1028 - 1033
  • [28] Coagulation Using High Intensity Focused Ultrasound (HIFU)
    Nguyen, Phuc V.
    Oh, Junghwan
    Kang, Hyun Wook
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [29] Hemorrhage control using high intensity focused ultrasound
    Vaezy, Shahram
    Zderic, Vesna
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) : 203 - 211
  • [30] Evaluation of pulsed high intensity focused ultrasound exposures on metastasis in a murine model
    Hilary Hancock
    Matthew R. Dreher
    Nigel Crawford
    Claire B. Pollock
    Jennifer Shih
    Bradford J. Wood
    Kent Hunter
    Victor Frenkel
    Clinical & Experimental Metastasis, 2009, 26 : 729 - 738