Deep tissue penetration of nanoparticles using pulsed-high intensity focused ultrasound

被引:14
|
作者
You, Dong Gil [1 ,2 ]
Yoon, Hong Yeol [2 ]
Jeon, Sangmin [1 ,2 ]
Um, Wooram [1 ,2 ]
Son, Sejin [2 ]
Park, Jae Hyung [1 ]
Kwon, Ick Chan [2 ,3 ]
Kim, Kwangmeyung [2 ,3 ]
机构
[1] Sungkyunkwan Univ, Sch Chem Engn, 2066 Seobu Ro, Suwon 16419, South Korea
[2] Korea Inst Sci & Technol, Biomed Res Inst, Ctr Theragnosi s, 5,Hwarang Ro 14 Gil, Seoul 02792, South Korea
[3] Korea Univ, KU KIST Grad Sch Converging Sci & Technol, 145 Anam Ro, Seoul 02841, South Korea
来源
NANO CONVERGENCE | 2017年 / 4卷
关键词
Pulsed-high intensity focused ultrasound; Tissue penetration; Nanoparticle; Drug delivery;
D O I
10.1186/s40580-017-0124-z
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Recently, ultrasound (US)-based drug delivery strategies have received attention to improve enhanced permeation and retention (EPR) effect-based passive targeting efficiency of nanoparticles in vitro and in vivo conditions. Among the US treatment techniques, pulsed-high intensity focused ultrasound (pHIFU) have specialized for improving tissue penetration of various macromolecules and nanoparticles without irreversible tissue damages. In this study, we have demonstrated that pHIFU could be utilized to improve tissue penetration of fluorescent dye-labeled glycol chitosan nanoparticles (FCNPs) in femoral tissue of mice. pHIFU could improve blood flow of the targeted-blood vessel in femoral tissue. In addition, tissue penetration of FCNPs was specifically increased 5.7-, 8- and 9.3-folds than that of non-treated (0W pHIFU) femoral tissue, when the femoral tissue was treated with 10, 20 and 50W of pHIFU, respectively. However, tissue penetration of FCNPs was significantly reduced after 3 h post-pHIFU treatment (50W). Because overdose (50W) of pHIFU led to irreversible tissue damages, including the edema and chapped red blood cells. These overall results support that pHIFU treatment can enhance the extravasation and tissue penetration of FCNPs as well as induce irreversible tissue damages. We expect that our results can provide advantages to optimize pHIFU-mediated delivery strategy of nanoparticles for further clinical applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Tissue Atomization by High Intensity Focused Ultrasound
    Simon, Julianna
    Sapozhnikov, Oleg
    Khokhlova, Vera
    Wang, Yak-Nam
    Crum, Lawrence
    Bailey, Michael
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1003 - 1006
  • [12] Sonochemical Synthesis of Gold Nanoparticles by Using High Intensity Focused Ultrasound
    Yusof, Nor Saadah Mohd
    Ashokkumar, Muthupandian
    CHEMPHYSCHEM, 2015, 16 (04) : 775 - 781
  • [13] Targeted Venous Occlusion Using Pulsed High-Intensity Focused Ultrasound
    Hwang, Joo Ha
    Zhou, Yufeng
    Warren, Cinderella
    Brayman, Andrew A.
    Crum, Lawrence A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) : 37 - 40
  • [14] Optimal Conditions for Tissue Perforation Using High Intensity Focused Ultrasound
    Mochizuki, Takashi
    Kihara, Taizo
    Ogawa, Kouji
    Tanabe, Ryoko
    Yosizawa, Shin
    Umemura, Shin-ichiro
    Kakimoto, Takashi
    Yamashita, Hiromasa
    Chiba, Toshio
    11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 245 - 249
  • [15] Delivery of liposomal doxorubicin (Doxil) in a breast cancer tumor model: Investigation of potential enhancement by pulsed-high intensity focused ultrasound exposure
    Frenkel, V
    Etherington, A
    Greene, M
    Quijano, J
    Xie, JW
    Hunter, F
    Dromi, S
    Li, KCP
    ACADEMIC RADIOLOGY, 2006, 13 (04) : 469 - 479
  • [16] MRI monitoring of the effect of tissue interfaces in the penetration of high intensity focused ultrasound in kidney in vivo
    Damianou, C
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (09): : 1209 - 1215
  • [17] Effect of hydrodynamic cavitation in the tissue erosion by pulsed high-intensity focused ultrasound (pHIFU)
    Zhou, Yufeng
    Gao, Xiaobin Wilson
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18): : 6651 - 6667
  • [18] Augmentation of targeted delivery with pulsed high intensity focused ultrasound
    O'Neill, Brian E.
    Li, King C. P.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2008, 24 (06) : 506 - 520
  • [19] Pulsed high intensity focused ultrasound increases penetration and therapeutic efficacy of monoclonal antibodies in murine xenograft tumors
    Wang, Shutao
    Shin, In Soo
    Hancock, Hilary
    Jang, Beom-su
    Kim, Hyung-sub
    Lee, Sang Myung
    Zderic, Vesna
    Frenkel, Victor
    Pastan, Ira
    Paik, Chang H.
    Dreher, Matthew R.
    JOURNAL OF CONTROLLED RELEASE, 2012, 162 (01) : 218 - 224
  • [20] Accurate targeting of myocardial tissue using high intensity focused ultrasound in mice
    Okajima, Kazue
    Abe, Yukio
    Suzuki, Keiko
    Fujimoto, Kohei
    Muratore, Robert
    Kalisz, Andrew
    Feleppa, Ernest J.
    Homma, Shunichi
    CIRCULATION, 2006, 114 (18) : 759 - 760