Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques

被引:12
|
作者
Yoon, Jihyung [1 ]
Heins, David [1 ]
Zhao, Xiaodong [1 ]
Sanders, Mary [2 ]
Zhang, Rui [1 ,2 ]
机构
[1] Louisiana State Univ, Dept Phys & Astron, Med Phys Program, Baton Rouge, LA 70803 USA
[2] Mary Bird Perkins Canc Ctr, Dept Radiat Oncol, Baton Rouge, LA 70809 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 23期
基金
美国国家卫生研究院;
关键词
post-mastectomy radiotherapy; out-of-field dose; volumetric modulated arc therapy; flattening-filter-free; mixed beam therapy; tomotherapy; intensity modulated radiation therapy; MODULATED RADIATION-THERAPY; TREATMENT PLANNING SYSTEM; ISCHEMIC-HEART-DISEASE; BREAST-CANCER PATIENTS; FLATTENING FILTER FREE; PHOTON BEAMS; MULTILEAF COLLIMATION; EXTERNAL-BEAM; MONTE-CARLO; MV BEAM;
D O I
10.1088/1361-6560/aa94b5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K-OBOF and in-beam out-of-field (IBOF) correction factor K-IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy(-1) for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.
引用
收藏
页码:9039 / 9053
页数:15
相关论文
共 50 条
  • [41] Measurements and Comparison of Out-Of-Field Organ Doses From Varian Clinac IMRT Plans Using the Atom Phantom
    Han, B.
    Dorgu, A.
    Pavord, D.
    Bednarz, B.
    Xu, X.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [42] Monte Carlo Simulation of Cobalt-60 Teletherapy Unit Modeling In-Field and Out-Of-Field Doses for Applications in Computational Radiation Dosimetry
    Petroccia, H.
    Li, Z.
    Mendenhall, N.
    Bolch, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3464 - 3464
  • [43] Characterization of Electron Beam Out-Of-Field Doses and Neutron Contamination from Modern Varian and Elekta Linear Accelerators
    Cardenas, C.
    Nitsch, P.
    Kudchadker, R.
    Howell, R.
    Kry, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3849 - 3850
  • [44] Evaluating out-of-field doses during radiotherapy of paediatric brain tumours using lead shielding and flattening-filter free beams
    Beierholm, Anders Ravnsborg
    Nygaard, Ditte Eklund
    Juhl, Elisabeth Lagoni
    Hansen, Rune
    Hansen, Jolanta
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 1 - 6
  • [45] Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators
    Cardenas, Carlos E.
    Nitsch, Paige L.
    Kudchadker, Rajat J.
    Howell, Rebecca M.
    Kry, Stephen F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 442 - 455
  • [46] Determining Out-of-Field Doses and Second Cancer Risk From Proton Therapy in Young Patients-An Overview
    Romero-Exposito, Maite
    Toma-Dasu, Iuliana
    Dasu, Alexandru
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [47] Low dose out-of-field radiotherapy, part 2: Calculating the mean photon energy values for the out-of-field photon energy spectrum from scattered radiation using Monte Carlo methods
    Skrobala, A.
    Adamczyk, S.
    Kruszyna-Mochalska, M.
    Skorska, M.
    Konefal, A.
    Suchorska, W.
    Zaleska, K.
    Kowalik, A.
    Jackowiak, W.
    Malicki, J.
    CANCER RADIOTHERAPIE, 2017, 21 (05): : 352 - 357
  • [48] Anatomical assessment of local recurrence site in breast cancer patients after breast reconstruction and post-mastectomy radiotherapy: implications for radiation volumes and techniques
    Salvestrini, Viola
    Valzano, Marianna
    Meattini, Icro
    Becherini, Carlotta
    Visani, Luca
    Francolini, Giulio
    Morelli, Ilaria
    Bertini, Niccolo
    Orzalesi, Lorenzo
    Bernini, Marco
    Bianchi, Simonetta
    Simontacchi, Gabriele
    Livi, Lorenzo
    Desideri, Isacco
    RADIOLOGIA MEDICA, 2024, 129 (06): : 845 - 854
  • [49] Comparison of Out-Of-Field Doses in Pediatric Patients From Craniospinal Irradiations Using Photon, Electron and Proton Spinal Fields
    Georgiev, G.
    Followill, D.
    Ibbott, G.
    Kry, S.
    Fontenot, J.
    White, A.
    Mahajan, A.
    MEDICAL PHYSICS, 2009, 36 (06) : 2583 - +
  • [50] Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours-a comparison of range shifter and 3D printed compensator
    Wochnik, A.
    Stolarczyk, L.
    Ambrozova, I
    Davidkova, M.
    De Saint-Hubert, M.
    Domanski, S.
    Domingo, C.
    Knezevic, Z.
    Kopec, R.
    Kuc, M.
    Majer, M.
    Mojzeszek, N.
    Mares, V
    Martinez-Rovira, I
    Caballero-Pacheco, M. A.
    Pyszka, E.
    Swakon, J.
    Trinkl, S.
    Tisi, M.
    Harrison, R.
    Olko, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):