Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques

被引:12
|
作者
Yoon, Jihyung [1 ]
Heins, David [1 ]
Zhao, Xiaodong [1 ]
Sanders, Mary [2 ]
Zhang, Rui [1 ,2 ]
机构
[1] Louisiana State Univ, Dept Phys & Astron, Med Phys Program, Baton Rouge, LA 70803 USA
[2] Mary Bird Perkins Canc Ctr, Dept Radiat Oncol, Baton Rouge, LA 70809 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 23期
基金
美国国家卫生研究院;
关键词
post-mastectomy radiotherapy; out-of-field dose; volumetric modulated arc therapy; flattening-filter-free; mixed beam therapy; tomotherapy; intensity modulated radiation therapy; MODULATED RADIATION-THERAPY; TREATMENT PLANNING SYSTEM; ISCHEMIC-HEART-DISEASE; BREAST-CANCER PATIENTS; FLATTENING FILTER FREE; PHOTON BEAMS; MULTILEAF COLLIMATION; EXTERNAL-BEAM; MONTE-CARLO; MV BEAM;
D O I
10.1088/1361-6560/aa94b5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K-OBOF and in-beam out-of-field (IBOF) correction factor K-IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy(-1) for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.
引用
收藏
页码:9039 / 9053
页数:15
相关论文
共 50 条
  • [31] OUT OF FIELD DOSE FROM ADVANCED TREATMENT TECHNIQUES
    Kry, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S60 - S60
  • [32] Out-of-field doses in pediatric craniospinal irradiations with 3D-CRT, VMAT, and scanning proton radiotherapy: A phantom study
    Majer, Marija
    Ambrozova, Iva
    Davidkova, Marie
    De Saint-Hubert, Marijke
    Kasabasic, Mladen
    Knezevic, Zeljka
    Kopec, Renata
    Krzempek, Dawid
    Krzempek, Katarzyna
    Miljanic, Saveta
    Mojzeszek, Natalia
    Versic, Ivan
    Stolarczyk, Liliana
    Harrison, Roger M.
    Olko, Pawel
    MEDICAL PHYSICS, 2022, 49 (04) : 2672 - 2683
  • [33] Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment
    Matsumoto, Shinnosuke
    Yonai, Shunsuke
    Bolch, Wesley E.
    MEDICAL PHYSICS, 2019, 46 (12) : 5824 - 5832
  • [34] Field-in-field plan versus tangential wedged beam plan in chest wall radiotherapy of post-mastectomy patients: Treatment planning study
    Yarahmadi M.
    Faramarzi B.
    Haghparast A.
    Saalehi Z.
    Haghparast, Abbas (a.haghparast@kums.ac.ir), 2017, Mashhad University of Medical Sciences (14) : 257 - 263
  • [35] Fabrication and development of a thorax phantom to evaluate 3D CRT treatment planning techniques for post-mastectomy chest wall radiotherapy
    Dilson Lobo
    Srinivas Challapalli
    Sourjya Banerjee
    Suman Kumar Putha
    P. U. Prakash Saxena
    Raghavendra Holla
    R. Shreyas
    Ravichandran Ramamoorthy
    Physical and Engineering Sciences in Medicine, 2021, 44 : 425 - 432
  • [36] Fabrication and development of a thorax phantom to evaluate 3D CRT treatment planning techniques for post-mastectomy chest wall radiotherapy
    Lobo, Dilson
    Challapalli, Srinivas
    Banerjee, Sourjya
    Putha, Suman Kumar
    Saxena, P. U. Prakash
    Holla, Raghavendra
    Shreyas, R.
    Ramamoorthy, Ravichandran
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 425 - 432
  • [37] Radiation dose and cancer risk to out-of-field and partially in-field organs from radiotherapy for symptomatic vertebral hemangiomas
    Mazonakis, Michalis
    Tzedakis, Antonis
    Lyraraki, Efrossyni
    Damilakis, John
    MEDICAL PHYSICS, 2016, 43 (04) : 1841 - 1848
  • [38] Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy with a passive beam: Organ doses in prostate cancer treatment
    Yonai, Shunsuke
    Matsufuji, Naruhiro
    Akahane, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 51 : 48 - 55
  • [39] Assessment of out-of-field radiation doses for high dose per pulse intraoperative electron beam radiotherapy using TLD-100
    Aghdam, Seyed Rashid Hosseini
    Aghamiri, Seyed Mahmoud Reza
    Siavashpour, Zahra
    Malekie, Shahryar
    Dashtipoor, Mohammad Reza
    RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [40] Out-of-Field Dose Measurement by TLD Dosimetry and Estimation of Radiation-Induced Secondary Cancer Risk of Thyroid and Breast from Head Radiotherapy
    Rahbar Yazdi S.
    Zare M.H.
    Broomand M.A.
    Journal of Biomedical Physics and Engineering, 2023, 13 (05): : 403 - 410