Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience

被引:34
|
作者
Briganti, Francesco [1 ]
Leone, Giuseppe [2 ]
Ugga, Lorenzo [2 ]
Marseglia, Mariano [1 ]
Solari, Domenico [3 ]
Caranci, Ferdinando [2 ]
Mariniello, Giuseppe [3 ]
Maiuri, Francesco [3 ]
Cappabianca, Paolo [3 ]
机构
[1] Univ Naples Federico II, Dept Adv Biomed Sci, Unit Intervent Neuroradiol, Via S Pansini 5, I-80131 Naples, Italy
[2] Federico II, Dept Adv Biomed Sci, Via S Pansini 5, I-80131 Naples, Italy
[3] Univ Naples Federico II, Div Neurosurg, Dept Neurosci Reprod & Odontostomatol Sci, Via S Pansini 5, I-80131 Naples, Italy
关键词
Intracranial aneurysm; Flow diverter devices; FRED; Endovascular treatment; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; DIVERTOR DEVICES; FOLLOW-UP; INITIAL-EXPERIENCE; ENDOVASCULAR TREATMENT; SILK STENT; METAANALYSIS; MULTICENTER; DIVERSION;
D O I
10.1007/s00701-016-2875-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Experience with the endovascular treatment of cerebral aneurysms by the Flow Re-Direction Endoluminal Device (FRED) is still limited. The aim of this study is to discuss the results and complications of this new flow diverter device (FDD). Between November 2013 and April 2015, 20 patients (15 female and five male) harboring 24 cerebral aneurysms were treated with FRED FDD in a single center. Complete occlusion was obtained in 20/24 aneurysms (83 %) and partial occlusion in four (17 %). Intraprocedural technical complication occurred in one case (4 %) and post-procedural complications in three (12 %). None reported neurological deficits (mRS = 0). All FRED were patent at follow-up. No early or delayed aneurysm rupture, no subarachnoid (SAH) or intraparenchymal hemorrhage (IPH) no ischemic complications and no deaths occurred. Endovascular treatment with FRED FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. The FRED is substantially equivalent to the other known FDDs, which show similar functions and technical profiles.
引用
收藏
页码:1745 / 1755
页数:11
相关论文
共 50 条
  • [31] Safety and Efficacy of Surgical Treatment of Intracranial Aneurysms: The Experience of a Single Brazilian Center
    Dellaretti, Marcos
    Ronconi, Daniel
    Batista, Danilo Malta
    de Souza, Renata Ferreira
    Romeu de Almeida, Carlos Eduardo
    Fontoura, Renato Rinco
    Botelho Antunes, Paulo Ramos
    Quadros, Ricardo Sousa
    WORLD NEUROSURGERY, 2018, 117 : E580 - E587
  • [32] Abnormal foreshortening of a Flow Re-Direction Endoluminal Device caused by in-stent thrombosis immediately after deployment br
    Otsuka, Takafumi
    Izumi, Takashi
    Nishihori, Masahiro
    Tsukada, Tetsuya
    Goto, Shunsaku
    Ikezawa, Mizuka
    Kato, Naoki
    Nakano, Mizuki
    Uda, Kenji
    Yokoyama, Kinya
    Araki, Yoshio
    Saito, Ryuta
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (04) : 884 - 889
  • [33] Safety and efficacy of flow redirection endoluminal device (FRED) for treatment of intracranial aneurysm; A systematic review and meta-analysis
    Habibi, Mohammad Amin
    Mirjani, Mohammad Sina
    Ahmadzadeh, Amir Mahmoud
    Javar, Mohammad Taha Akbari
    Karami, Shaghayegh
    Ahmadvand, Muhammad Hussain
    NEURORADIOLOGY JOURNAL, 2025, 38 (02): : 142 - 175
  • [34] Endovascular treatment of challenging aneurysms with FRED Jr flow diverter stents: a single-center experience
    Sayin, Bige
    Senol, Yigit Can
    Daglioglu, Ergun
    Ozbakir, Musa Onur
    Orhan, Gurdal
    Akmangit, Ilkay
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (03) : 322 - 334
  • [35] Endovascular treatment of challenging aneurysms with FRED Jr flow diverter stents: a single-center experience
    Bige Sayin
    Yiğit Can Şenol
    Ergün Daglioglu
    Musa Onur Özbakır
    Gürdal Orhan
    İlkay Akmangit
    Japanese Journal of Radiology, 2023, 41 : 322 - 334
  • [36] Percutaneous endoluminal treatment of peripheral aneurysms. A single center experience with a series of 35 aneurysms
    Henry, M
    Amor, M
    Henry, I
    Tzvetanov, K
    Kholer, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 453A - 453A
  • [37] Safety and efficacy of flow diverter stents in the treatment of middle cerebral artery aneurysms: a single-center experience and follow-up data
    Soydemir, Efe
    Gundogmus, Cemal Aydin
    Tureli, Derya
    Baltacioglu, Nurten Andac
    Bayri, Yasar
    Baltacioglu, Feyyaz
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (02): : 350 - 358
  • [38] Percutaneous endoluminal treatment of peripheral aneurysms. A single center experience with a series of 43 aneurysms
    Henry, M
    Amor, M
    Henry, I
    Amicabile, C
    Buniet, JM
    CIRCULATION, 1998, 98 (17) : 548 - 549
  • [39] Flow diversion in the treatment of intracranial aneurysms using the novel FRED X device: An early experience from a single high-volume center
    Clausen, Thomas Mandel
    Nakamura, Ryan
    Conching, Andie
    Choi, Joo Won
    Zhang, Yi Jonathan
    Hui, Ferdinand
    Tsappidi, Samuel
    INTERVENTIONAL NEURORADIOLOGY, 2025,
  • [40] Experience with FRED junior flow diverter in treatment of cerebral aneurysms at or distal to the circle of Willis
    Sivasankar, Rajeev
    Shrivastava, Manish
    Limaye, Uday S.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 69 : 166 - 169