A novel genosensor based on Fe3O4@SiO2/DABCO-modified screen-printed graphite electrode for detection of prostate cancer gene sequence hybridization

被引:8
|
作者
Abedi, Rokhsareh [1 ]
Raoof, Jahan Bakhsh [1 ]
Hashkavayi, Ayemeh Bagheri [1 ,2 ]
Asghari, Maryam [1 ]
Azimi, Razieh [3 ]
Hejazi, Mohammad Saeid [4 ,5 ,6 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Electroanalyt Chem Res Lab, Babolsar, Iran
[2] Tech & Vocat Univ TVU, Fac Alzahra, Dept Chem Ind, Bushehr Branch, Bushehr, Iran
[3] Res Inst Forests & Rangelands Agr Res Educ & Exte, Tehran, Iran
[4] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[5] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz, Iran
[6] Tabriz Univ Med Sci, Pharmaceut Nanotechnol Res Ctr, Tabriz, Iran
关键词
DNA hybridization biosensor; Prostate cancer gene; Differential pulse voltammetry; Guanine; Hemin; Genosensor; ELECTROCHEMICAL APTASENSOR; DNA BIOSENSOR; ANTIGEN; LABEL; NANOPARTICLES; DIAGNOSIS; MUTATION; APTAMER; SENSOR; PSA;
D O I
10.1007/s13738-021-02480-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An electrochemical DNA hybridization biosensor developed based on graphite screen-printed electrodes (GSPEs) modified with Fe3O4@SiO2/DABCO was used for detection of short-sequence DNA of prostate cancer gene by using two different methods including direct and indirect. The proposed sensor was prepared by immobilization of a 19-mer ssDNA probe on the modified GSPEs surface for detecting the hybridization between the probe and its complementary and non-complementary sequence of the prostate cancer gene as a target. The hybridization process was detected based on the differential pulse voltammetric signals of the guanine oxidation and the hemin reduction as an electrochemical indicator through direct and indirect methods, respectively. The selectivity of the biosensor was studied by the using of non-complementary oligonucleotide strands capable of distinguishing complementary and non-complementary DNA sequence of the prostate cancer gene. The peak current intensity of guanine oxidation and hemin reduction showed an enhancement by increasing the concentrations of complementary strands from 1.0 x 10(-11) to 2.0 x 10(-6) M and 7.5 x 10(-12) to 2.0 x 10(-6) M, respectively. The limits of detection, LOD (based on 3 sigma), were found as 8.0 x 10(-12) M and 6.4 x 10(-12) M for direct and indirect detection methods, respectively.
引用
收藏
页码:2631 / 2640
页数:10
相关论文
共 50 条
  • [21] Selective electrochemical determination of bisphenol A via a Fe3O4 NPs derivative-modified graphite screen-printed electrode
    Jahani, Peyman Mohammadzadeh
    Beitollahi, Hadi
    Tajik, Somayeh
    Tashakkorian, Hamed
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (11) : 1209 - 1225
  • [22] A Screen-Printed Electrode Modified With Graphene/Co3O4 Nanocomposite for Electrochemical Detection of Tramadol
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Beitollahi, Hadi
    Zhang, Kaiqiang
    Van Le, Quyet
    Cha, Joo Hwan
    Jang, Ho Won
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [23] Electrochemical Sensor for Detection of Hydrochlorothiazide Based on Screen-Printed Electrode Modified with ZnO/Al2O3 Nanocomposite
    Zaimbashi, Reza
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2022, 58 (06) : 752 - 760
  • [25] Highly sensitive and selective electrochemical paper-based device using a graphite screen-printed electrode modified with molecularly imprinted polymers coated Fe3O4@Au@SiO2 for serotonin determination
    Amatatongchai, Maliwan
    Sitanurak, Jirayu
    Sroysee, Wongduan
    Sodanat, Suriyaphon
    Chairam, Sanoe
    Jarujamrus, Purim
    Nacapricha, Duangjai
    Lieberzeit, Peter A.
    ANALYTICA CHIMICA ACTA, 2019, 1077 : 255 - 265
  • [26] Electrochemical myoglobin biosensor based on carbon ionic liquid electrode modified with Fe3O4@SiO2 microsphere
    Xiaofeng Wang
    Zheng You
    Hailiang Sha
    Zhaolan Sun
    Wei Sun
    Journal of Solid State Electrochemistry, 2014, 18 : 207 - 213
  • [27] Electrochemical myoglobin biosensor based on carbon ionic liquid electrode modified with Fe3O4@SiO2 microsphere
    Wang, Xiaofeng
    You, Zheng
    Sha, Hailiang
    Sun, Zhaolan
    Sun, Wei
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (01) : 207 - 213
  • [28] Voltammetric detection of sumatriptan in the presence of naproxen using Fe3O4@ZIF-8 nanoparticles modified screen printed graphite electrode
    Somayeh Tajik
    Mahboobeh Shahsavari
    Iran Sheikhshoaie
    Fariba Garkani Nejad
    Hadi Beitollahi
    Scientific Reports, 11
  • [29] Voltammetric detection of sumatriptan in the presence of naproxen using Fe3O4@ZIF-8 nanoparticles modified screen printed graphite electrode
    Tajik, Somayeh
    Shahsavari, Mahboobeh
    Sheikhshoaie, Iran
    Nejad, Fariba Garkani
    Beitollahi, Hadi
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [30] Screen-printed graphite electrode modified with Co3O4 nanoparticles and 2D graphitic carbon nitride as an effective electrochemical sensor for 4-aminophenol detection
    Jahani, Peyman Mohammadzadeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    Dourandish, Zahra
    Di Bartolomeo, Antonio
    NANOTECHNOLOGY, 2022, 33 (39)