A novel genosensor based on Fe3O4@SiO2/DABCO-modified screen-printed graphite electrode for detection of prostate cancer gene sequence hybridization

被引:8
|
作者
Abedi, Rokhsareh [1 ]
Raoof, Jahan Bakhsh [1 ]
Hashkavayi, Ayemeh Bagheri [1 ,2 ]
Asghari, Maryam [1 ]
Azimi, Razieh [3 ]
Hejazi, Mohammad Saeid [4 ,5 ,6 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Electroanalyt Chem Res Lab, Babolsar, Iran
[2] Tech & Vocat Univ TVU, Fac Alzahra, Dept Chem Ind, Bushehr Branch, Bushehr, Iran
[3] Res Inst Forests & Rangelands Agr Res Educ & Exte, Tehran, Iran
[4] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[5] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz, Iran
[6] Tabriz Univ Med Sci, Pharmaceut Nanotechnol Res Ctr, Tabriz, Iran
关键词
DNA hybridization biosensor; Prostate cancer gene; Differential pulse voltammetry; Guanine; Hemin; Genosensor; ELECTROCHEMICAL APTASENSOR; DNA BIOSENSOR; ANTIGEN; LABEL; NANOPARTICLES; DIAGNOSIS; MUTATION; APTAMER; SENSOR; PSA;
D O I
10.1007/s13738-021-02480-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An electrochemical DNA hybridization biosensor developed based on graphite screen-printed electrodes (GSPEs) modified with Fe3O4@SiO2/DABCO was used for detection of short-sequence DNA of prostate cancer gene by using two different methods including direct and indirect. The proposed sensor was prepared by immobilization of a 19-mer ssDNA probe on the modified GSPEs surface for detecting the hybridization between the probe and its complementary and non-complementary sequence of the prostate cancer gene as a target. The hybridization process was detected based on the differential pulse voltammetric signals of the guanine oxidation and the hemin reduction as an electrochemical indicator through direct and indirect methods, respectively. The selectivity of the biosensor was studied by the using of non-complementary oligonucleotide strands capable of distinguishing complementary and non-complementary DNA sequence of the prostate cancer gene. The peak current intensity of guanine oxidation and hemin reduction showed an enhancement by increasing the concentrations of complementary strands from 1.0 x 10(-11) to 2.0 x 10(-6) M and 7.5 x 10(-12) to 2.0 x 10(-6) M, respectively. The limits of detection, LOD (based on 3 sigma), were found as 8.0 x 10(-12) M and 6.4 x 10(-12) M for direct and indirect detection methods, respectively.
引用
收藏
页码:2631 / 2640
页数:10
相关论文
共 50 条
  • [41] Evaluation of the Usefulness of an Electrochemical Sensor in Detecting Ascorbic Acid using a Graphite Screen-printed Electrode Modified with NiFe2O4 Nanoparticles
    Jahani, Shohreh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 739 - 750
  • [42] A novel H2O2 biosensor based on Fe3O4-Au magnetic nanoparticles coated horseradish peroxidase and graphene sheets-Nafion film modified screen-printed carbon electrode
    Yang Xin
    Xiao Fu-bing
    Lin Hong-wei
    Wu Feng
    Chen Di-zhao
    Wu Zhao-yang
    ELECTROCHIMICA ACTA, 2013, 109 : 750 - 755
  • [43] A novel disposable electrochemical sensor for determination of carbamazepine based on Fe doped SnO2 nanoparticles modified screen-printed carbon electrode
    Lavanya, N.
    Sekar, C.
    Ficarra, S.
    Tellone, E.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 62 : 53 - 60
  • [44] Screen-Printed Graphite Electrode Modified with Graphene-Co3O4 Nanocomposite: Voltammetric Assay of Morphine in the Presence of Diclofenac in Pharmaceutical and Biological Samples
    Beitollahi, Hadi
    Nejad, Fraiba Garkani
    Tajik, Somayeh
    Di Bartolomeo, Antonio
    NANOMATERIALS, 2022, 12 (19)
  • [45] Fabrication of magnetic iron oxide-supported copper oxide nanoparticles (Fe3O4/CuO): modified screen-printed electrode for electrochemical studies and detection of desipramine
    Tajik, Somayeh
    Beitollahi, Hadi
    Aflatoonian, Mohammad Reza
    Mohtat, Bita
    Aflatoonian, Behnaz
    Shoaie, Iran Sheikh
    Khalilzadeh, Mohammad A.
    Ziasistani, Marzieh
    Zhang, Kaiqiang
    Jang, Ho Won
    Shokouhimehr, Mohammadreza
    RSC ADVANCES, 2020, 10 (26) : 15171 - 15178
  • [46] Functionalizing Fe3O4@SiO2 with a novel mercaptobenzothiazole derivative: Application to trace fluorometric and colorimetric detection of Fe3+ in water
    Mir, Noshin
    Karimi, Pouya
    Castano, Carlos E.
    Norouzi, Nazgol
    Rojas, Jessika, V
    Mohammadi, Reza
    APPLIED SURFACE SCIENCE, 2019, 487 (876-888) : 876 - 888
  • [47] An electrochemical acetaminophen sensor based on La3+/Co3O4 nanoflowers modified graphite screen printed electrode architecture
    Sheikhshoaie, Iran
    Nejad, Fariba Garkani
    Beitollahi, Hadi
    INTERNATIONAL JOURNAL OF NANO DIMENSION, 2019, 10 (02) : 154 - 162
  • [48] Modified electrode by using magnetic core–shell Fe3O4@SiO2/MWCNT nanoparticles for determination of 6-mercaptopurine
    Iman Abyar
    Hamideh Asadollahzadeh
    Sayed Zia Mohammadi
    Mehdi Shahidi
    Mahdieh Ghazizadeh
    Journal of Materials Science: Materials in Electronics, 2023, 34
  • [49] A Sensitive Acetylcholinesterase Biosensor Based on Screen Printed Electrode Modified with Fe3O4 Nanoparticle and Graphene for Chlorpyrifos Determination
    Wang, Hui
    Zhao, Guo
    Chen, Dongfei
    Wang, Zhiqiang
    Liu, Gang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12): : 10906 - 10918
  • [50] The development of disposable electrochemical sensor based on Fe3O4-doped reduced graphene oxide modified magnetic screen-printed electrode for ractopamine determination in pork sample
    Poo-arporn, Yingyot
    Pakapongpan, Saithip
    Chanlek, Narong
    Poo-arporn, Rungtiva P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 164 - 171