The diagnostic value of D-dimer in acute aortic dissection: a meta-analysis

被引:39
|
作者
Yao, Jian
Bai, Tao
Yang, Bo
Sun, Lizhong [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, 2 Anzhen Rd, Beijing 100029, Peoples R China
关键词
D-dimer; Acute aortic dissection; Meta-analysis; Diagnostic value; C-REACTIVE PROTEIN; ACUTE PULMONARY-EMBOLISM; BIOMARKERS; SERUM; RATIO; MORTALITY; OUTCOMES; PREDICT;
D O I
10.1186/s13019-021-01726-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective This study aims to evaluate the diagnostic value of D-dimer for acute aortic dissection (AAD) by the method of meta-analysis. Methods PubMed, Cochrane Library, Web of Science, Embase, China National Knowledge Infrastructure (CNKI), and Wanfang databases from the establishment of the databases to December 2020 were systematically searched, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) system was used to evaluate the quality of the literature. STATA 15.0 software was applied to calculate the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (+LR), negative likelihood ratio (-LR) to draw summary receiver operating characteristics (SROC) curve and calculate the area under the curve (AUC). Meta-regression and subgroup analyses were used to explore the source of heterogeneity. Results A total of 16 clinical studies were enrolled in this study, including 1135 patients. The results of the meta-analysis showed that the pooled sensitivity was 0.96 (95% CI 0.91-0.98), the pooled specificity was 0.70 (95% CI 0.57-0.81), and the pooled DOR was 56.57 (95% CI 25.11-127.44), the pooled +LR was 3.25 (95% CI 2.18-4.85), the pooled -LR was 0.06 (95% CI 0.03-0.12), and the AUC was 0.94 (95% CI 0.91-0.95). Meta-regression and subgroup analysis results showed that publication year, sample size and cutoff value might be sources of heterogeneity. When the concentration of D-dimer was less than or equal to 500 ng/ml, the sensitivity significantly increased. Conclusion D-dimer has an excellent diagnostic value for AAD. It is a useful tool for detecting suspected AAD because of the excellent pooled sensitivity. D-dimer <= 500 ng/ml increases the potential to identify the suspected patients with AAD.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] D-dimer and BNP levels in acute aortic dissection
    Sbarouni, Eftihia
    Georgiadou, Panagiota
    Marathias, Aikaterini
    Geroulanos, Stefanos
    Kremastinos, Dimitrios Th.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 122 (02) : 170 - 172
  • [22] Negative D-dimer Test for Acute Aortic Dissection
    Satoh, Yukio
    Suzuki, Masaru
    Shiroshita-Takeshita, Akiko
    Tamura, Tomonori
    Kurihara, Tomohiro
    Shimizu, Hideyuki
    Hori, Shingo
    CIRCULATION, 2011, 124 (21)
  • [23] Detection of acute thoracic aortic dissection with D-dimer
    VanderLinden, Chad
    EMERGENCY MEDICINE JOURNAL, 2007, 24 (12) : 846 - 847
  • [24] Investigating the Efficiency of D-Dimer Test in Diagnosis of Aortic Dissection: A Systematic Study and Meta-Analysis
    Ahmadi, Iraj
    Qavam, Samira Mis
    Sayehmiri, Kourosh
    Golitaleb, Mohamad
    Tavan, Hamed
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2018, 12 (04) : 142 - 147
  • [25] The diagnostic value of circulating D-dimer levels in patients with acute aortic dissection as compared to those with intramural hematoma
    Faure, A.
    Ohlmann, P.
    Morel, O.
    Jesel, L.
    Trinh, A.
    Horduna, I.
    Roul, G.
    Bareiss, P.
    EUROPEAN HEART JOURNAL, 2006, 27 : 265 - 265
  • [26] DIAGNOSIS OF ACUTE AORTIC DISSECTION BY D DIMER - A META ANALYSIS
    Shimony, A.
    Filion, K.
    Mottillo, S.
    Eisenberg, M. J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 60D - 60D
  • [27] Combined use of aortic dissection detection risk score and D-dimer in the diagnostic workup of suspected acute aortic dissection
    Nazerian, Peiman
    Morello, Fulvio
    Vanni, Simone
    Bono, Alessia
    Castelli, Matteo
    Forno, Daniela
    Gigli, Chiara
    Soardo, Flavia
    Carbone, Federica
    Lupia, Enrico
    Grifoni, Stefano
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (01) : 78 - 82
  • [28] Impact of D-dimer on in-hospital mortality following aortic dissection: A systematic review and meta-analysis
    Srikanth, Sashwath
    Abrishami, Shabnam
    Subramanian, Lakshmi
    Mahadevaiah, Ashwini
    Vyas, Ankit
    Jain, Akhil
    Nathaniel, Sangeetha
    Gnanaguruparan, Subramanian
    Desai, Rupak
    WORLD JOURNAL OF CARDIOLOGY, 2024, 16 (06): : 355 - 362
  • [29] A Retrospective Analysis of Serum D-Dimer Levels for the Exclusion of Acute Aortic Dissection
    Zitek, Tony
    Hashemi, Mani
    Zagroba, Sara
    Slane, Valori H.
    OPEN ACCESS EMERGENCY MEDICINE, 2022, 14 : 367 - 372
  • [30] IMPACT OF D-DIMER ON IN-HOSPITAL MORTALITY FOLLOWING AORTIC DISSECTION: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Srikanth, Sashwath
    Mahadevaiah, Ashwini
    Abrishami, Shabnam
    Niaz, Rabiya
    Aqeel, Mariam
    Narula, Harshit
    Thota, Anjani
    Saeed, Memoona
    Singh, Monika
    Yarrarapu, Siva Naga
    Desai, Rupak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 2060 - 2060