Prediction of the anastomosis angle of arteriovenous fistula in hemodialysis to standardize the surgical technique

被引:8
|
作者
Shembekar, Suraj N. [1 ]
Zodpe, D. B. [1 ]
Padole, P. M. [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Mech Engn, Nagpur 440010, Maharashtra, India
关键词
Arteriovenous fistula; anastomosis angle; hemodialysis; vascular access; wall shear stress; TO-SIDE ANASTOMOSIS; BLOOD-FLOW; NUMERICAL-SIMULATION; VASCULAR ACCESS; HEMODYNAMICS; VISCOSITY; SITES; SHEAR;
D O I
10.3233/BME-211389
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Arteriovenous fistula (AVF) is the preferred route of vascular access in hemodialysis. The primary reason of fistula failure is intimal hyperplasia (IH), which leads to stenosis. Wall shear stress (WSS) and disturbed flow are the critical parameters in the formation of IH. OBJECTIVE: The primary goal of this study is to explore the influence of anastomosis angle on WSS and venous outflow rate, as well as to find the ideal angle of anastomosis for AVF to standardize surgical technique. METHODS: Three-dimensional idealized geometries of end-to-side type AVF for the five various angles of anastomosis are considered in this study. The WSS, blood flow rate at the venous outlet for non-Newtonian, pulsatile blood flow are calculated using a numerical simulation technique. RESULTS: The WSS is higher at 75 degrees compared to other angles and least at 45 degrees for pulsating arterial inflows. The WSS is moderate at 30 degrees, 60 degrees and 90 degrees. On the arterial bed and outer wall of the vein, immediately after the anastomosis, the recirculation zone is observed. At an angle of 45 degrees and 90 degrees anastomosis, the outflow rate is greater at distal venous end. CONCLUSIONS: If one believes that high wall shear stress causes IH within the AVF, the results suggest that the AVF should be formed at a 45 degrees angle to avoid IH. However, if one believes that low wall shear stress causes IH within the AVF, the results suggest that AVF should be formed at either 30 degrees or 75 degrees to avoid IH. The findings spotlight the importance of anastomosis angle in determining AVF hemodynamics.
引用
收藏
页码:423 / 436
页数:14
相关论文
共 50 条
  • [31] BASILIC-HUERAL ARTERIOVENOUS FISTULA - NEW TECHNIQUE FOR CHRONIC HEMODIALYSIS
    GARZAV, LDL
    CHAVEZPE.F
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 1973, 25 (01): : 67 - 73
  • [32] Stent-graft arteriovenous fistula: An endovascular technique in hemodialysis access
    Masuda, EM
    Kistner, RL
    Eklof, B
    Lipman, RA
    Balkin, PW
    Kamida, CB
    JOURNAL OF ENDOVASCULAR SURGERY, 1998, 5 (01): : 18 - 23
  • [33] Sharp Needle Recanalization Technique for Peripheral Hemodialysis Arteriovenous Fistula Occlusion
    Noh, Seung Yeon
    Goo, Dong Erk
    Kim, Yong Jae
    Yang, Seung Boo
    Lee, Jae Myeong
    Lee, Woong Hee
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (11) : 1809 - 1816
  • [34] Effect of Anastomosis Angle on Hemodynamic of Side-to-end Radiocephalic Arteriovenous Fistula (RCAVF)
    Hassan, Wan Anuar Wan
    Osman, Kahar
    Kadir, Mohammed Rafiq Abdul
    Abdullah, Wan Ahmad Kamil Wan
    Haron, Juhara
    Ngali, Mohd Zamani
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 665 - 670
  • [35] ARTERIOVENOUS VERTEBRAL FISTULA - SURGICAL TECHNIQUE BY PARAMEDIAN POSTERIOR APPROACH
    BERTHELOT, JL
    COUFFINHAL, JC
    COQUILLAUD, JP
    ANDREASSIAN, B
    NEUROCHIRURGIE, 1982, 28 (05) : 315 - 318
  • [36] ARTERIOVENOUS FISTULAS FOR CHRONIC INTERMITTENT HEMODIALYSIS - MODIFIED SURGICAL TECHNIQUE
    HASHMONAI, M
    SCHRAMEK, A
    CHAIMOVITZ, C
    ERLIK, D
    BRITISH JOURNAL OF SURGERY, 1972, 59 (12) : 953 - 956
  • [37] No-touch technique for radiocephalic arteriovenous fistula - surgical technique and preliminary results
    Horer, Tal M.
    Skoog, Per
    Quell, Robin
    Nilsson, Kristofer F.
    Larzon, Thomas
    Souza, Domingos R.
    JOURNAL OF VASCULAR ACCESS, 2016, 17 (01): : 6 - 12
  • [38] Comparison between Surgical and Endovascular Hemodialysis Arteriovenous Fistula Interventions and Associated Costs
    Arnold, Renee J. G.
    Han, Yun
    Balakrishnan, Rajesh
    Layton, Andrew
    Lok, Charmaine E.
    Glickman, Marc
    Rajan, Dheeraj K.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (11) : 1558 - 1566
  • [39] SURGICAL TREATMENT OF STAPHYLOCOCCUS-AUREUS ENDARTERITIS - HEMODIALYSIS ARTERIOVENOUS-FISTULA
    SILVERMAN, NA
    GUNNELLS, JC
    STICKLE, DL
    ARCHIVES OF SURGERY, 1974, 108 (05) : 730 - 732
  • [40] Hemodialysis Arteriovenous Fistula Related Complications and Surgical Interventions in Kidney Graft Recipients
    Vajdic, B.
    Ponikvar, R.
    Kandus, A.
    Buturovic Ponikvar, J.
    TRANSPLANTATION, 2012, 94 (10) : 911 - 911