Prediction of the anastomosis angle of arteriovenous fistula in hemodialysis to standardize the surgical technique

被引:8
|
作者
Shembekar, Suraj N. [1 ]
Zodpe, D. B. [1 ]
Padole, P. M. [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Mech Engn, Nagpur 440010, Maharashtra, India
关键词
Arteriovenous fistula; anastomosis angle; hemodialysis; vascular access; wall shear stress; TO-SIDE ANASTOMOSIS; BLOOD-FLOW; NUMERICAL-SIMULATION; VASCULAR ACCESS; HEMODYNAMICS; VISCOSITY; SITES; SHEAR;
D O I
10.3233/BME-211389
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Arteriovenous fistula (AVF) is the preferred route of vascular access in hemodialysis. The primary reason of fistula failure is intimal hyperplasia (IH), which leads to stenosis. Wall shear stress (WSS) and disturbed flow are the critical parameters in the formation of IH. OBJECTIVE: The primary goal of this study is to explore the influence of anastomosis angle on WSS and venous outflow rate, as well as to find the ideal angle of anastomosis for AVF to standardize surgical technique. METHODS: Three-dimensional idealized geometries of end-to-side type AVF for the five various angles of anastomosis are considered in this study. The WSS, blood flow rate at the venous outlet for non-Newtonian, pulsatile blood flow are calculated using a numerical simulation technique. RESULTS: The WSS is higher at 75 degrees compared to other angles and least at 45 degrees for pulsating arterial inflows. The WSS is moderate at 30 degrees, 60 degrees and 90 degrees. On the arterial bed and outer wall of the vein, immediately after the anastomosis, the recirculation zone is observed. At an angle of 45 degrees and 90 degrees anastomosis, the outflow rate is greater at distal venous end. CONCLUSIONS: If one believes that high wall shear stress causes IH within the AVF, the results suggest that the AVF should be formed at a 45 degrees angle to avoid IH. However, if one believes that low wall shear stress causes IH within the AVF, the results suggest that AVF should be formed at either 30 degrees or 75 degrees to avoid IH. The findings spotlight the importance of anastomosis angle in determining AVF hemodynamics.
引用
收藏
页码:423 / 436
页数:14
相关论文
共 50 条
  • [21] Hemodialysis using an arteriovenous fistula
    Scribner, BH
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1999, 10 (01): : 198 - 199
  • [22] Clinical use of computational modeling for surgical planning of arteriovenous fistula for hemodialysis
    Michela Bozzetto
    Stefano Rota
    Valentina Vigo
    Francesco Casucci
    Carlo Lomonte
    Walter Morale
    Massimo Senatore
    Luigi Tazza
    Massimo Lodi
    Giuseppe Remuzzi
    Andrea Remuzzi
    BMC Medical Informatics and Decision Making, 17
  • [23] Clinical use of computational modeling for surgical planning of arteriovenous fistula for hemodialysis
    Bozzetto, Michela
    Rota, Stefano
    Vigo, Valentina
    Casucci, Francesco
    Lomonte, Carlo
    Morale, Walter
    Senatore, Massimo
    Tazza, Luigi
    Lodi, Massimo
    Remuzzi, Giuseppe
    Remuzzi, Andrea
    BMC MEDICAL INFORMATICS AND DECISION MAKING, 2017, 17
  • [24] Computational study on anastomosis size and angle of arterio-venous fistula for hemodialysis
    Van Canneyt, K.
    Guillame, C.
    Bonnet, A.
    Pourchez, T.
    Segers, P.
    Verdonck, P.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 : 219 - 220
  • [25] INTERNAL ARTERIOVENOUS FISTULA FOR HEMODIALYSIS
    THOMPSON, BW
    BARBOUR, G
    BISSETT, J
    AMERICAN JOURNAL OF SURGERY, 1972, 124 (06): : 785 - 788
  • [26] Disconnection of arteriovenous fistula: Standardize the coverage of the hemorragic risk
    Delfosse, Fleur
    Boyer, Julien
    Lemaitre, Vincent
    Inghels, Yves
    NEPHROLOGIE & THERAPEUTIQUE, 2012, 8 (01): : 23 - 34
  • [27] HEMODIALYSIS USING AN ARTERIOVENOUS FISTULA
    不详
    NEW ENGLAND JOURNAL OF MEDICINE, 1966, 275 (20): : 1134 - +
  • [28] Anchor versus parachute suturing technique in arteriovenous fistula creation for hemodialysis
    Mabrouk, Moustafa
    Atta, Islam
    Fouda, Ahmed
    Ismail, Khalid
    Ismail, Taha
    Gawish, Rasha
    Elkassaby, Mohammed
    VASCULAR, 2024,
  • [29] Cannulation Technique an Arteriovenous Fistula Survival in Older Adult Patients on Hemodialysis
    Stolic, Radojica V.
    Trajkovic, Goran Z.
    Kostic, Mirjana M.
    Lazic, Bratislav D.
    Odalovic, Bozidar
    Smilic, Tanja N.
    Mitic, Javorka S.
    NEPHROLOGY NURSING JOURNAL, 2017, 44 (05) : 441 - 446
  • [30] Sharp Needle Recanalization Technique for Peripheral Hemodialysis Arteriovenous Fistula Occlusion
    Seung Yeon Noh
    Dong Erk Goo
    Yong Jae Kim
    Seung Boo Yang
    Jae Myeong Lee
    Woong Hee Lee
    CardioVascular and Interventional Radiology, 2021, 44 : 1809 - 1816